Dynamic spectrum: a brand-new non-invasive blood component measure method

被引:0
|
作者
Li, Gang [1 ]
Wang, Yan [1 ]
Lin, Ling [1 ]
Liu, Yuliang [1 ]
Li, Xiaoxia [1 ]
Lu, Stephen C-Y. [1 ]
机构
[1] Tianjin Univ, Inspiring Tech Lab, Coll Precis Instruments & Optoelect Engn, Tianjin 300072, Peoples R China
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a brand-new method that fits the non-invasive blood component concentration measurement: the dynamic spectrum (DS) method. With use of this method, it was possible to eliminate the main interference of the individual discrepancy and extract some kinds of the blood component concentration by the analytic method. The definition, principle and measure method of the dynamic spectrum are presented in this paper. According to the theory, this method can get rid of main influence from the skin individual discrepancy theoretically. The achievement, study progress and remain work of this method are also introduced in this paper. Three kind of study of the DS are discussed in this paper.
引用
收藏
页码:1960 / 1963
页数:4
相关论文
共 50 条
  • [1] Non-Invasive Measurement of Human Blood Cholesterol Concentration Based on Dynamic Spectrum Method
    Suo Yong-kuan
    Li Gang
    Wang Hui-quan
    Lin Ling
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (01) : 188 - 191
  • [2] Dynamic Spectrum in frequency domain on non-invasive in vivo measurement of blood spectrum
    Li, XX
    Li, G
    Lin, L
    Liu, YL
    Wang, Y
    Zhang, YF
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 688 - 696
  • [3] Non-invasive measurement of haemoglobin based on dynamic spectrum method
    Wang, Huiquan
    Li, Gang
    Zhao, Zhe
    Lin, Ling
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2013, 35 (01) : 16 - 24
  • [4] Non-Invasive Measurement of Human Hemoglobin Concentration by Dynamic Spectrum Method
    Zhang Zhi-yong
    Men Jian-long
    Li Gang
    Lin Ling
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (01) : 150 - 153
  • [5] NON-INVASIVE METHOD FOR THE DYNAMIC MEASUREMENT OF CEREBRAL BLOOD-FLOW
    COHN, R
    HURLEY, CW
    KLATZO, I
    STROKE, 1979, 10 (01) : 100 - 100
  • [6] A joint evaluation method of dynamic spectrum extraction methods for non-invasive blood component measurement based on stability coefficient, data point adoption rate, and smoothness of the spectrum
    Lin, Ling
    Zeng, Honghui
    Wang, Shuo
    Cheng, Leiyang
    Wang, Kang
    Li, Gang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 244
  • [7] Non-invasive detection of the content of white blood cells in the blood of humans based on dynamic spectrum
    Huo, Yanxi
    Liu, Guozhong
    Jing, Rixing
    Zhao, Peng
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (05)
  • [8] Non-invasive MRI method to measure arterial function
    Pilla, JJ
    Dougherty, L
    Ferrari, VA
    CIRCULATION, 2003, 107 (19) : E169 - E169
  • [9] A NEW METHOD FOR THE NON-INVASIVE MEASUREMENT OF PULPAL BLOOD-FLOW
    WILDERSMITH, PEEB
    INTERNATIONAL ENDODONTIC JOURNAL, 1988, 21 (05) : 307 - 312
  • [10] Application of Wavelet Transform on Iimproving Detecting Precision of the Non-Invasive Blood Components Measurement Based on Dynamic Spectrum Method
    Li Gang
    Men Jian-long
    Sun Zhao-min
    Wang Hui-quan
    Lin Ling
    Tong Ying
    Zhang Bao-ju
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (02) : 469 - 472