Proximal cementation of a collarless polished tapered hip stem: biomechanical analysis using a validated finite element model

被引:0
|
作者
Ling, Carol Sze Yee [1 ]
Izmin, Aiman [2 ]
Todo, Mitsugu [2 ,3 ]
Merican, Azhar M. [1 ]
Chong, Desmond Y. R. [1 ,4 ]
机构
[1] Univ Malaya, Fac Med, Dept Orthopaed Surg, Kuala Lumpur, Malaysia
[2] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Fukuoka, Japan
[3] Kyushu Univ, Res Inst Appl Mech, Fukuoka, Japan
[4] Singapore Inst Technol, Engn Cluster, 10 Dover Dr, Singapore 138683, Singapore
关键词
Total hip replacement; Finite element analysis; Cemented fixation; Proximal cementing; Validated FE model; FEMORAL STEM; ARTHROPLASTY; FRACTURE; PREDICTION; PATTERNS; STRENGTH; BEHAVIOR; SURFACE; STRAIN; VARUS;
D O I
10.1007/s11517-024-03152-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Total hip replacement (THR) with cemented stem is a common procedure for patients with hip osteoarthritis. When primary THR fails, removal of the cement is problematic and poses challenges during revision surgeries. The possibility of proximal partial cementing of the hip stem was explored to mitigate the problem. 3D finite element analysis was performed to investigate the feasibility of reduced cement length for effective implant fixation and load transmission. Three levels of cement reduction (40 mm, 80 mm, and 100 mm) in the femoral stem were evaluated. All models were assigned loadings of peak forces acting on the femur during walking and stair climbing. The experimental and predicted max/min principal bone strains were fitted into regression models and showed good correlations. FE results indicated stress increment in the femoral bone, stem, and cement due to cement reduction. A notable increase of bone stress was observed with large cement reduction of 80-100 mm, particularly in Gruen zones 3 and 5 during walking and Gruen zones 3 and 6 during stair climbing. The increase of cement stresses could be limited to 11% with a cement reduction of 40 mm. The findings suggested that a 40-mm cement reduction in hip stem fixation was desirable to avoid unwanted complications after cemented THR.
引用
收藏
页码:3531 / 3542
页数:12
相关论文
共 50 条
  • [31] A Biomechanical and Finite Element Analysis of Femoral Neck Notching During Hip Resurfacing
    Davis, Edward T.
    Olsen, Michael
    Zdero, Rad
    Papini, Marcello
    Waddell, James P.
    Schemitsch, Emil H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04):
  • [32] Minimum 10-Year Follow-Up of Total Hip Arthroplasty With a Collarless Triple-Tapered Polished Cemented Stem With Line-to-Line Implantation Using a Direct Anterior Approach
    Miyamoto, Shuichi
    Iida, Satoshi
    Suzuki, Chiho
    Kawamoto, Taisei
    Shinada, Yoshiyuki
    Ohtori, Seiji
    JOURNAL OF ARTHROPLASTY, 2022, 37 (11): : 2214 - 2224
  • [33] Biomechanical Behavior of an Hydroxyapatite-Coated Traditional Hip Stem and a Short One of Similar Design: Comparative Study Using Finite Element Analysis
    Gomez-Vallejo, Jesus
    Roces-Garcia, Jorge
    Moreta, Jesus
    Donaire-Hoyas, Daniel
    Gayoso, Oscar
    Marques-Lopez, Fernando
    Albareda, Jorge
    ARTHROPLASTY TODAY, 2021, 7 : 167 - 176
  • [34] Finite Element Analysis of Porous Titanium Alloy Hip Stem to Evaluate the Biomechanical Performance During Walking and Stair Climbing
    Sami Emad Alkhatib
    Hassan Mehboob
    Faris Tarlochan
    Journal of Bionic Engineering, 2019, 16 : 1103 - 1115
  • [35] Biomechanical Investigation of the Impact of Femoral Stem Size on Stress Distribution in Total Hip Arthroplasty: A Finite Element Analysis Study
    Rezaei, Shahabedine
    Rajaeirad, Mohadese
    Kamal, Zeinab
    Gilakjani, Hassan Asadi
    Khorsandi, Mohammad
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 279 - 283
  • [36] Finite Element Analysis of Porous Titanium Alloy Hip Stem to Evaluate the Biomechanical Performance During Walking and Stair Climbing
    Alkhatib, Sami Emad
    Mehboob, Hassan
    Tarlochan, Faris
    JOURNAL OF BIONIC ENGINEERING, 2019, 16 (06) : 1103 - 1115
  • [37] A Finite Element Analysis Model is Suitable for Biomechanical Analysis of Orbital Development
    Song, Dongyu
    Zhang, Jiwu
    Yuan, Bowei
    Rong, Qiguo
    Li, Dongmei
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (07) : 2546 - 2550
  • [38] A biomechanical model of Smilodon fatalis based on finite element analysis
    McHenry, Colin
    Cunningham, Eleanor
    Wroe, Stephen
    Pendharkar, Aral
    Clausen, Philip
    JOURNAL OF VERTEBRATE PALEONTOLOGY, 2006, 26 (03) : 98A - 98A
  • [39] Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
    Orwoll, Eric S.
    Marshall, Lynn M.
    Nielson, Carrie M.
    Cummings, Steven R.
    Lapidus, Jodi
    Cauley, Jane A.
    Ensrud, Kristine
    Lane, Nancy
    Hoffmann, Paul R.
    Kopperdahl, David L.
    Keaveny, Tony M.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2009, 24 (03) : 475 - 483
  • [40] Investigation on various proximal femoral stem shapes for human hip prosthesis using finite element concepts0
    Boobalan, V.
    Shankar, S.
    2013, Society for Biomaterials and Artificial Organs - India (27): : 153 - 161