Proximal cementation of a collarless polished tapered hip stem: biomechanical analysis using a validated finite element model

被引:0
|
作者
Ling, Carol Sze Yee [1 ]
Izmin, Aiman [2 ]
Todo, Mitsugu [2 ,3 ]
Merican, Azhar M. [1 ]
Chong, Desmond Y. R. [1 ,4 ]
机构
[1] Univ Malaya, Fac Med, Dept Orthopaed Surg, Kuala Lumpur, Malaysia
[2] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Fukuoka, Japan
[3] Kyushu Univ, Res Inst Appl Mech, Fukuoka, Japan
[4] Singapore Inst Technol, Engn Cluster, 10 Dover Dr, Singapore 138683, Singapore
关键词
Total hip replacement; Finite element analysis; Cemented fixation; Proximal cementing; Validated FE model; FEMORAL STEM; ARTHROPLASTY; FRACTURE; PREDICTION; PATTERNS; STRENGTH; BEHAVIOR; SURFACE; STRAIN; VARUS;
D O I
10.1007/s11517-024-03152-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Total hip replacement (THR) with cemented stem is a common procedure for patients with hip osteoarthritis. When primary THR fails, removal of the cement is problematic and poses challenges during revision surgeries. The possibility of proximal partial cementing of the hip stem was explored to mitigate the problem. 3D finite element analysis was performed to investigate the feasibility of reduced cement length for effective implant fixation and load transmission. Three levels of cement reduction (40 mm, 80 mm, and 100 mm) in the femoral stem were evaluated. All models were assigned loadings of peak forces acting on the femur during walking and stair climbing. The experimental and predicted max/min principal bone strains were fitted into regression models and showed good correlations. FE results indicated stress increment in the femoral bone, stem, and cement due to cement reduction. A notable increase of bone stress was observed with large cement reduction of 80-100 mm, particularly in Gruen zones 3 and 5 during walking and Gruen zones 3 and 6 during stair climbing. The increase of cement stresses could be limited to 11% with a cement reduction of 40 mm. The findings suggested that a 40-mm cement reduction in hip stem fixation was desirable to avoid unwanted complications after cemented THR.
引用
收藏
页码:3531 / 3542
页数:12
相关论文
共 50 条
  • [21] Biomechanical analysis of cement materials for vertebroplasty using a finite element fracture model
    Wilcox, RK
    PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 67 - 71
  • [22] Biomechanical assessment of mandibular fracture fixation using finite element analysis validated by polymeric mandible mechanical testing
    Daqiq, Omid
    Roossien, Charlotte Christina
    Wubs, Frederik Wilhelm
    van Minnen, Baucke
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Finite Element Analysis of Proximal Cement Fixation in Total Hip Arthroplasty
    Ahmad, Maizatul Afirah
    Zulkifli, Nurul Nadhirah Mohamed Elias
    Shuib, Solehuddin
    Sulaiman, Shahrul Hisham
    Abdullah, Abdul Halim
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (05) : 1046 - 1055
  • [24] Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up
    Grzesiak, Arthur
    Aminian, Kamiar
    Lecureux, Estelle
    Jobin, Florence
    Jolles, Brigitte M.
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 717 - 724
  • [25] Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up
    Arthur Grzesiak
    Kamiar Aminian
    Estelle Lécureux
    Florence Jobin
    Brigitte M. Jolles
    International Orthopaedics, 2014, 38 : 717 - 724
  • [26] Effects of femoral bone defect morphology on initial polished tapered stem stability in massive defect model: a biomechanical study
    Tohru Irie
    Daisuke Takahashi
    Tsuyoshi Asano
    Tomohiro Shimizu
    Ryuta Arai
    Alaa Muhammad Terkawi
    Yoichi M. Ito
    Norimasa Iwasaki
    BMC Musculoskeletal Disorders, 20
  • [27] Effects of femoral bone defect morphology on initial polished tapered stem stability in massive defect model: a biomechanical study
    Irie, Tohru
    Takahashi, Daisuke
    Asano, Tsuyoshi
    Shimizu, Tomohiro
    Arai, Ryuta
    Terkawi, Alaa Muhammad
    Ito, Yoichi M.
    Iwasaki, Norimasa
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [28] Finite Element Analysis and Biomechanical Testing of the New MiniMIS Short Stem
    Trieb, Klemens
    Huber, Dominik
    Sonntag, Robert
    Kretzer, Jan Philippe
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2019, 157 (02): : 188 - 193
  • [29] Biomechanical Analysis of Lateral Lumbar Interbody Fusion Constructs with Various Fixation Options: Based on a Validated Finite Element Model
    Zhang, Zhenjun
    Fogel, Guy R.
    Liao, Zhenhua
    Sun, Yitao
    Liu, Weiqiang
    WORLD NEUROSURGERY, 2018, 114 : E1120 - E1129
  • [30] Biomechanical study of the resurfacing hip arthroplasty - Finite element analysis of the femoral component
    Watanabe, Y
    Shiba, N
    Matsuo, S
    Higuchi, F
    Tagawa, Y
    Inoue, A
    JOURNAL OF ARTHROPLASTY, 2000, 15 (04): : 505 - 511