Exploring the Potential of a Novel Iodine-Based Material as an Alternative Contrast Agent in X-ray Imaging Studies

被引:0
|
作者
Bliznakova, Kristina [1 ]
Kolev, Iliyan [2 ]
Dukov, Nikolay [1 ]
Dimova, Tanya [2 ]
Bliznakov, Zhivko [1 ]
机构
[1] Med Univ Varna, Fac Publ Hlth, Dept Med Equipment Elect & Informat Technol Health, Varna 9002, Bulgaria
[2] Med Univ Varna, Fac Pharm, Dept Pharmaceut Chem, Varna, Bulgaria
关键词
radiocontrast agent; X-ray imaging; physical phantoms; simulations; ENHANCED SPECTRAL MAMMOGRAPHY; BREAST; OPTIMIZATION; SUBTRACTION; PHANTOMS;
D O I
10.3390/ma17092059
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Background: Contrast-enhanced mammography is one of the new emerging imaging techniques used for detecting breast tissue lesions. Optimization of imaging protocols and reconstruction techniques for this modality, however, requires the involvement of physical phantoms. Their development is related to the use of radiocontrast agents. This study assesses the X-ray properties of a novel contrast material in clinical settings. This material is intended for experimental use with physical phantoms, offering an alternative to commonly available radiocontrast agents. Materials and Methods: The water-soluble sodium salt of the newly synthesized diiodine-substituted natural eudesmic acid, Sodium 2,6-DiIodo-3,4,5-TriMethoxyBenzoate [NaDITMB], has been investigated with respect to one of the most commonly applied radiocontrast medium in medical practice-Omnipaque (R). For this purpose, simulation and experimental studies were carried out with a computational phantom and a physical counterpart, respectively. Synthetic and experimental X-ray images were subsequently produced under varying beam kilovoltage peaks (kVps), and the proposed contrast material was evaluated. Results and Discussion: Simulation results revealed equivalent absorptions between the two simulated radiocontrast agents. Experimental findings supported these simulations, showing a maximum deviation of 3.7% between the image gray values of contrast materials for NaDITMB and Omnipaque solutions for a 46 kVp X-ray beam. Higher kVp X-ray beams show even smaller deviations in the mean grey values of the imaged contrast agents, with the NaDITMB solution demonstrating less than a 2% deviation compared to Omnipaque. Conclusion: The proposed contrast agent is a suitable candidate for use in experimental work related to contrast-enhanced imaging by utilizing phantoms. It boasts the advantages of easy synthesis and is recognized for its safety, ensuring a secure environment for both the experimenter and the environment.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] STRUCTURAL STUDIES OF A PARTICULATE X-RAY CONTRAST AGENT - A MULTIMETHOD APPROACH
    TONNESSEN, LE
    FOSSHEIM, R
    KLAVENESS, J
    PEDERSEN, BF
    THOMASSEN, T
    ACTA CHEMICA SCANDINAVICA, 1995, 49 (09): : 625 - 631
  • [32] Modelling of a novel x-ray phase contrast imaging technique based on coded apertures
    Olivo, A.
    Speller, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (22): : 6555 - 6573
  • [33] A new formula of phase contrast imaging for continuous X-ray based on in-line X-ray imaging
    Xia, Tian
    Ma, Jun Shan
    Cheng, Jing Hai
    Yang, Jun
    COMPUTING, CONTROL, INFORMATION AND EDUCATION ENGINEERING, 2015, : 333 - 336
  • [34] An alternative X-ray shielding material based on coated textiles
    Aral, Nebahat
    Nergis, F. Banu
    Candan, Cevza
    TEXTILE RESEARCH JOURNAL, 2016, 86 (08) : 803 - 811
  • [35] Acoustically modulated X-ray phase contrast and vibration potential imaging
    Beveridge, AC
    Bailat, CJ
    Hamilton, TJ
    Wang, S
    Rose-Petruck, C
    Gusev, VE
    Diebold, GJ
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2005, 2005, 5697 : 90 - 98
  • [36] Imaging efficiency of an X-ray contrast agent-incorporated polymeric microparticle
    Ahn, Sungsook
    Jung, Sung Yong
    Lee, Jin Pyung
    Lee, Sang Joon
    CONTRAST MEDIA & MOLECULAR IMAGING, 2011, 6 (06) : 437 - 448
  • [37] Iodine Vapor Staining for Atomic Number Contrast in Backscattered Electron and X-Ray Imaging
    Boyde, Alan
    Mccorkell, Fergus A.
    Taylor, Graham K.
    Bomphrey, Richard J.
    Doube, Michael
    MICROSCOPY RESEARCH AND TECHNIQUE, 2014, 77 (12) : 1044 - 1051
  • [38] Phase-contrast X-ray imaging based on interferometry
    Momose, A
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 136 - 142
  • [39] Diffraction Enhance X-ray Imaging for Quantitative Phase Contrast Studies
    Agrawal, A. K.
    Singh, B.
    Kashyap, Y. S.
    Shukla, Mayank
    Sarkar, P. S.
    Sinha, Amar
    DAE SOLID STATE PHYSICS SYMPOSIUM 2015, 2016, 1731
  • [40] Design of a novel phase contrast X-ray imaging system for mammography
    Munro, Peter R. T.
    Ignatyev, Konstantin
    Speller, Robert D.
    Olivo, Alessandro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 824 - 828