Exploring the Potential of a Novel Iodine-Based Material as an Alternative Contrast Agent in X-ray Imaging Studies

被引:0
|
作者
Bliznakova, Kristina [1 ]
Kolev, Iliyan [2 ]
Dukov, Nikolay [1 ]
Dimova, Tanya [2 ]
Bliznakov, Zhivko [1 ]
机构
[1] Med Univ Varna, Fac Publ Hlth, Dept Med Equipment Elect & Informat Technol Health, Varna 9002, Bulgaria
[2] Med Univ Varna, Fac Pharm, Dept Pharmaceut Chem, Varna, Bulgaria
关键词
radiocontrast agent; X-ray imaging; physical phantoms; simulations; ENHANCED SPECTRAL MAMMOGRAPHY; BREAST; OPTIMIZATION; SUBTRACTION; PHANTOMS;
D O I
10.3390/ma17092059
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Background: Contrast-enhanced mammography is one of the new emerging imaging techniques used for detecting breast tissue lesions. Optimization of imaging protocols and reconstruction techniques for this modality, however, requires the involvement of physical phantoms. Their development is related to the use of radiocontrast agents. This study assesses the X-ray properties of a novel contrast material in clinical settings. This material is intended for experimental use with physical phantoms, offering an alternative to commonly available radiocontrast agents. Materials and Methods: The water-soluble sodium salt of the newly synthesized diiodine-substituted natural eudesmic acid, Sodium 2,6-DiIodo-3,4,5-TriMethoxyBenzoate [NaDITMB], has been investigated with respect to one of the most commonly applied radiocontrast medium in medical practice-Omnipaque (R). For this purpose, simulation and experimental studies were carried out with a computational phantom and a physical counterpart, respectively. Synthetic and experimental X-ray images were subsequently produced under varying beam kilovoltage peaks (kVps), and the proposed contrast material was evaluated. Results and Discussion: Simulation results revealed equivalent absorptions between the two simulated radiocontrast agents. Experimental findings supported these simulations, showing a maximum deviation of 3.7% between the image gray values of contrast materials for NaDITMB and Omnipaque solutions for a 46 kVp X-ray beam. Higher kVp X-ray beams show even smaller deviations in the mean grey values of the imaged contrast agents, with the NaDITMB solution demonstrating less than a 2% deviation compared to Omnipaque. Conclusion: The proposed contrast agent is a suitable candidate for use in experimental work related to contrast-enhanced imaging by utilizing phantoms. It boasts the advantages of easy synthesis and is recognized for its safety, ensuring a secure environment for both the experimenter and the environment.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] THE EFFECTS OF X-RAY-ENERGY AND AN IODINE-BASED CONTRAST AGENT ON CHROMOSOME-ABERRATIONS
    MATSUBARA, S
    KATOH, T
    KUBOTA, N
    YOSHINO, N
    SASAKI, T
    SASAKI, MS
    RADIATION RESEARCH, 1994, 137 (02) : 231 - 237
  • [2] Optimization of an Iodine-based Nanoparticle Contrast Agent for Molecular CT Imaging
    Ghaghada, Ketan B.
    Patel, Chandreshkumar
    Annapragada, Ananth
    MEDICAL IMAGING 2018: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2018, 10578
  • [3] Quantitative imaging of Iodine-based contrast agent in dual-energy DBT
    Sidky, Emil Y.
    Wu, Xiangyi
    Duan, Xiaoyu
    Huang, Hailiang
    Zhao, Wei
    Zhang, Leo Y.
    Phillips, John Paul
    Zhang, Zheng
    Chen, Buxin
    Xia, Dan
    Reiser, Ingrid S.
    Pan, Xiaochuan
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [4] Evaluation and Comparison of Iodine-Based and Biosynthesized Gold Nanoparticles as X-Ray Contrast Agent and Their Effects on Renal Functions in Male Wistar Rats
    Ayanlola, Paul Sola
    Isola, Gbadebo Adebisi
    Saka, Waidi Adeoye
    Akinloye, Margaret Kofoworola
    Aremu, Abraham Adewale
    Lawal, Mustapha Kola
    Iranian Journal of Medical Physics, 2024, 21 (05): : 295 - 305
  • [5] Determination of free iodine concentration in an X-ray contrast agent
    Kljubin, V. V.
    Kljubina, K. A.
    Makovetskaya, K. N.
    OPTICS AND SPECTROSCOPY, 2016, 120 (04) : 546 - 550
  • [6] Determination of free iodine concentration in an X-ray contrast agent
    V. V. Kljubin
    K. A. Kljubina
    K. N. Makovetskaya
    Optics and Spectroscopy, 2016, 120 : 546 - 550
  • [7] GOLD NANOPARTICLES AS A CONTRAST AGENT FOR X-RAY IMAGING
    Kubiliute, Reda
    Slektaite, Akvile
    Burkanas, Marius
    Grigiene, Ruta
    Rotomskis, Ricardas
    MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 27 - +
  • [8] Characterization of a Novel Hafnium-Based X-ray Contrast Agent
    Frenzel, Thomas
    Bauser, Marcus
    Berger, Markus
    Hilger, Christoph Stephan
    Hegele-Hartung, Christa
    Jost, Gregor
    Neis, Christian
    Hegetschweiler, Kaspar
    Riefke, Bjoern
    Suelzle, Detlev
    Pietsch, Hubertus
    INVESTIGATIVE RADIOLOGY, 2016, 51 (12) : 776 - 785
  • [9] Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging
    De la Vega, Jose Carlos
    Esquinas, Pedro Luis
    Gill, Jovan Kaur
    Jessa, Selin
    Gill, Bradford
    Thakur, Yogesh
    Saatchi, Katayoun
    Hafeli, Urs O.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2021, 2021
  • [10] Galactosylated iodine-based small molecule IV CT contrast agent for bile duct imaging
    Jung, Yeonjin
    Hwang, Hee Sook
    Na, Kun
    BIOMATERIALS, 2018, 160 : 15 - 23