Galactosylated iodine-based small molecule IV CT contrast agent for bile duct imaging

被引:9
|
作者
Jung, Yeonjin [1 ]
Hwang, Hee Sook [1 ]
Na, Kun [1 ]
机构
[1] Catholic Univ Korea, Dept Biotechnol, 43 Jibong Ro, Bucheon Si 14662, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Computed tomography; Contrast agent; Bile duct; Medical imaging; SURFACE MODIFICATION; LACTOBIONIC ACID; PERFORMANCE; TOMOGRAPHY; CHOLANGIOGRAPHY; MECHANISMS; DISEASE;
D O I
10.1016/j.biomaterials.2018.01.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography (CT) with contrast plays an important role as a clinical diagnostic tool but still has a limited diagnostic range. In this work, we developed a novel injectable iodine-based small molecule CT contrast agent, even can be used for bile duct diagnostics. The bile duct diagnosable CT contrast agent (BDICA) is synthesized with 5-amino-2,4,6-triiodoisophthaloyl dichloride (ATIPC), tromethamine and lactobionic acid (LBA) for asialoglycoprotein receptor (ASGPR) targeted delivery via receptor-mediated endocytosis and transport to the bile canaliculi. Specific binding to the ASGPRs was confirmed by in vitro cellular uptake in HepG2 cells (ASGPR positive) and HCT 116 cells (ASGPR negative). Compared to iohexol, BDICA has equal in vivo distribution and a 13-fold iodine increase in content was observed in bile juice after BDICA injection. The radiopaque contrast effect in the bile duct has been clearly shown in in vivo CT scans. Furthermore, within 36 h, 91.3% of the BDICA was eliminated without organ damage, which verified the overall safety of the contrast agent. BDICA not only provides sufficient contrast images similar to iohexol, but also provides superior images of the bile duct. Based on recent studies, it has been shown that BDICA is a promising, safe and effective contrast agent for CT imaging of the organs and soft tissues, including the bile duct. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 50 条
  • [1] Optimization of an Iodine-based Nanoparticle Contrast Agent for Molecular CT Imaging
    Ghaghada, Ketan B.
    Patel, Chandreshkumar
    Annapragada, Ananth
    MEDICAL IMAGING 2018: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2018, 10578
  • [2] Liposomal nanodelivery systems for iodine-based CT contrast agent
    Koudelka, S.
    Jelinkova, V.
    Turanek, J.
    Mikulik, R.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 181 - 181
  • [3] Quantitative imaging of Iodine-based contrast agent in dual-energy DBT
    Sidky, Emil Y.
    Wu, Xiangyi
    Duan, Xiaoyu
    Huang, Hailiang
    Zhao, Wei
    Zhang, Leo Y.
    Phillips, John Paul
    Zhang, Zheng
    Chen, Buxin
    Xia, Dan
    Reiser, Ingrid S.
    Pan, Xiaochuan
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [4] An unusual adverse reaction to iodine-based contrast agent
    Menegatti, Mirta
    Pirisi, Mario
    Bellan, Mattia
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2016, 32 : E5 - E6
  • [5] ASSESSMENT OF ADVERSE REACTIONS DUE TO AN IODINE-BASED CONTRAST AGENT
    Joaquim, J.
    Matos, C.
    Pires, T.
    Fonseca, F.
    Tavares, O.
    Ramos, L.
    Rocha, M.
    CLINICAL THERAPEUTICS, 2015, 37 (08) : E103 - E104
  • [6] Liposomal nanodelivery systems for iodine-based CT contrast agents
    Koudelka, S.
    Jelinkova, V.
    Turanek, J.
    Mikulik, R.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 182 - 182
  • [7] Effect of Iodine-based Contrast Material on Radiation Dose at CT
    Abadi, Ehsan
    Sahbaee, Pooyan
    Samei, Ehsan
    RADIOLOGY, 2017, 285 (03) : 1053 - 1054
  • [8] Intraperitoneal administration of an iodine-based contrast agent to improve abdominal micro-computed tomography imaging in mice
    Johnson, EM
    Price, RE
    Rivera, B
    Cody, DD
    CONTEMPORARY TOPICS IN LABORATORY ANIMAL SCIENCE, 2005, 44 (06): : 20 - 27
  • [9] Exploring the Potential of a Novel Iodine-Based Material as an Alternative Contrast Agent in X-ray Imaging Studies
    Bliznakova, Kristina
    Kolev, Iliyan
    Dukov, Nikolay
    Dimova, Tanya
    Bliznakov, Zhivko
    MATERIALS, 2024, 17 (09)
  • [10] The Effect of Iodine-based Contrast Material on Radiation Dose at CT: It's Complicated
    Boone, John M.
    Hernandez, Andrew M.
    RADIOLOGY, 2017, 283 (03) : 624 - 627