Heating and defrosting performance assessment of dual-source heat pump operational modes under various ambient conditions

被引:0
|
作者
Panigrahi, Bivas [1 ]
Chang, Chia Wei [1 ]
Hsieh, Wen Chien [1 ]
Luo, Win Jet [1 ,2 ]
机构
[1] Natl Chin Yi Univ Technol, Dept Refrigerat Air Conditioning & Energy Engn, Taichung 41170, Taiwan
[2] Natl Chin Yi Univ Technol, Grad Inst Precis Mfg, Taichung 41170, Taiwan
来源
关键词
Dual -source heat pump; Air -source heat pump; Water -source heat pump; Fin tube evaporator; Hot water bypass defrosting method; Energy -efficient heat pump; SYSTEMS; SOLAR; AIR; ENERGY; WATER; ABSORPTION;
D O I
10.1016/j.jobe.2024.109359
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Multifunctional dual-source heat pump systems, featuring two sets of heat exchangers (air-torefrigerant and water-to-refrigerant) in series or parallel, aim to boost efficiency. However, these systems often require extensive piping, leading to power losses, higher energy consumption, and increased installation space requirements. Furthermore, few comparative studies have assessed the effectiveness of dual-source versus single-source heat pump systems under various ambient conditions. This study introduces a novel air-water dual-source evaporator design that enables efficient heat exchange using air, water, or both. With this design, the heat pump system can be tuned according to three distinct modes: pure water-source mode (WSHP), pure air-source mode (ASHP), and dual air-water-source mode (AWSHP). The heat pump's efficiency across these modes was evaluated under various weather conditions, adhering to the CNS15466 and GB/ T21362 standards. The findings reveal a strong correlation between the operational modes and ambient temperatures, indicating that maximum efficiency is achieved with the WSHP mode below 7 degrees C, AWSHP mode between 10 degrees C and 35 degrees C, and ASHP mode above 35 degrees C. Moreover, three defrosting methods were evaluated: hot gas bypass, hot water bypass, and a combination of both. The hot water bypass, in conjunction with the proposed dual-source evaporator design, efficiently performed full defrosting, boosting system efficiency. The ability of the heat pump to switch between operating modes enhances the overall energy efficiency during space heating and defrosting, reduces installation space requirements and compressor oil loss, and facilitates hot water production. The proposed system is ideal for various industrial applications requiring efficient operation under diverse ambient conditions.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Refrigeration characteristics of a hybrid heat dissipation photovoltaic-thermal heat pump under various ambient conditions on summer night
    Lu, Shixiang
    Zhang, Jili
    Liang, Ruobing
    Zhou, Chao
    RENEWABLE ENERGY, 2020, 146 : 2524 - 2534
  • [42] EXPERIMENTAL STUDY ON PERFORMANCE OF PHOTOVOLTAIC DIRECT-DIRVEN PV/T DUAL-SOURCE HEAT PUMP HOT WATER SYSTEM
    Chu L.
    Zhao S.
    Gao Y.
    Liu C.
    Zhang X.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (05): : 188 - 194
  • [43] Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review
    Xiong, Tong
    Liu, Guoqiang
    Gao, Qiang
    Yan, Gang
    Yu, Jianlin
    JOURNAL OF BUILDING ENGINEERING, 2023, 64
  • [44] Energy, economic and environmental analysis of a photovoltaic-thermal integrated dual-source heat pump system under a system coefficient of performance - based switching strategy
    Sang, Xuejing
    Qu, Minglu
    Yan, Nannan
    Li, Zhao
    Liu, Hongzhi
    ENERGY AND BUILDINGS, 2024, 323
  • [45] Yearly photoelectric/thermal and economic performance comparison between CPV and FPV dual-source heat pump systems in different regions
    Song, Zhiying
    Zhang, Yuzhe
    Ji, Jie
    He, Wei
    Hu, Zhongting
    Xuan, Qingdong
    ENERGY, 2024, 289
  • [46] Experimental performance evaluation and parametric study of a solar-ground source heat pump system operated in heating modes
    Yang, Weibo
    Zhang, Heng
    Liang, Xingfu
    ENERGY, 2018, 149 : 173 - 189
  • [47] Performance of biogas engine driven air source heat pump system under variable conditions
    Wu J.
    Ma Y.
    Cao W.
    Wu, Jiying (wjyjw@jmu.edu.cn), 1600, Materials China (71): : 3789 - 3796
  • [48] Experimental investigation on an air source heat pump system with coupled liquid-storage gas-liquid separator regarding heating and defrosting performance
    Ma, Longxia
    Wang, Fenghao
    Wang, Zhihua
    Zhang, Sheng
    Liu, Zixuan
    Lou, Yechun
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 134 : 176 - 188
  • [49] Experimental evaluation of the performance characteristics of a heat pump clothing care system under various operating conditions
    Park, Sunghoo
    Lee, Dongchan
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 192
  • [50] Experimental investigation on the space heating performance of air source heat pump with vapor injection under frosting condition
    Wei, Wenzhe
    Feng, Zhenglei
    Sun, Yuying
    Wang, Wei
    Jin, Xinyue
    Zhang, Jianfei
    Dai, Chuanmin
    JOURNAL OF BUILDING ENGINEERING, 2024, 90