Simulated Fewer-Angle SPECT/CT Imaging Protocol for Parathyroid Adenoma

被引:0
|
作者
Ficke, Jennifer B. [1 ]
Watson, Nora L. [2 ]
Stocker, Derek J. [1 ]
Schlegel, Kevin E. [1 ]
Sahajwalla, Maya C. [1 ]
Adams, Chad C. [3 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Dept Radiol, Bethesda, MD 20814 USA
[2] Walter Reed Natl Mil Med Ctr, Dept Res Programs, Bethesda, MD USA
[3] Eisenhower Army Med Ctr, Dept Radiol, Augusta, GA USA
关键词
SPECT/CT; FASpecT; parathyroid adenoma; RECONSTRUCTION ALGORITHMS; LOCALIZATION; SCINTIGRAPHY; QUALITY;
D O I
10.2967/jnmt.122.264649
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new SPECT/CT protocol for parathyroid imaging detailing fewer image -angle acquisitions (fewer -angle SPECT/CT [FASpecT/CT]) was evaluated for identification of parathyroid adenoma. The motivation for validating this protocol was to be able to use it in the future to decrease patient imaging time in our clinic. Methods: This was a retrospective review of existing data performed as a simulated case control study evaluating 50 parathyroid SPECT/CT scans acquired using the standard 60 -stop protocol and the tested 15 -stop FASpecT protocol acquired using angular sampling software. Agreement on the final interpretations between imaging methods was evaluated using the McNemar test and the Cohen K . Interrater reliability among the 3 readers was described for each method using the Fleiss K interpreted as in the strength -ofagreement guidelines by Landis and Koch. Results: Of the 50 evaluated images, 45 (90%) had concordant final image interpretations between imaging methods. The sensitivity of FASpecT/CT relative to SPECT/CT was 17 of 19 (89.5%; 95% CI, 66.9%-98.7%), and the specificity was 28 of 31 (90.3%; 95% CI, 74.2%-98.0%). Additionally, there was statistically significant substantial agreement between protocols and among readers for each protocol. Conclusion: Adequate diagnostic -quality SPECT/CT images can be acquired using significantly fewer imaging stops given advances in camera quality and processing algorithms such as iterative reconstruction. ize surgical localization ble nonpathologic SPECT/CT added diagnosis planar nation ciency, patient 10 delayed clinics delayed lar will compared approximately
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [21] Ectopic Parathyroid Adenoma of the Piriform Sinus on Parathyroid 4D-CT and 99mTc-MIBI SPECT/CT
    Hsieh, Meng-Chieh P.
    Nemer, John S.
    Beylergil, Volkan
    Yeh, Randy
    CLINICAL NUCLEAR MEDICINE, 2020, 45 (08) : E358 - E359
  • [22] SPECT/CT, planar imaging, and ultrasound in parathyroid lesion localization
    Berk, Fatma
    Beyder, Dmitry
    Nance, Robert
    Shindo, Maisie
    Stevens, Jeffrey
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [23] Parathyroid Imaging and Localization Using SPECT/CT: Initial Results
    Vaz, Ana
    Griffiths, Marc
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2011, 39 (03) : 195 - 200
  • [24] Is there an advantage of SPECT/CT over planar subtraction parathyroid imaging?
    Jurasinovic, Z.
    Tomic-Brzac, H.
    Petrovic, R.
    Bracic, I.
    Horvatic-Herceg, G.
    Tezak, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S397 - S397
  • [25] PERSONALIZED NUCLEAR IMAGING PROTOCOL IN CASES WITH NODULAR GOITER AND PARATHYROID ADENOMA
    Jalloul, W.
    Tibu, R.
    Ionescu, T. M.
    Stolniceanu, C. R.
    Grierosu, I
    Tarca, A.
    Ionescu, L.
    Ungureanu, M. C.
    Ciobanu, D.
    Ghizdovat, V
    Stefanescu, C.
    ACTA ENDOCRINOLOGICA-BUCHAREST, 2021, 17 (03)
  • [26] ACCURACY OF CHOLINE PET/CT VS TC 99M SESTAMIBI SPECT/CT PARATHYROID IMAGING IN COMPARISON TO HISTOPATHOLOGY IN THE DIAGNOSIS OF PARATHYROID ADENOMA: A META-ANALYSIS
    Tecson, Bettina
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [27] Successful removal of intrathyroidal parathyroid adenoma diagnosed and accurately located preoperatively by parathyroid scintigraphy (SPECT-CT)
    Kaushal, Dinesh Kumar
    Mishra, Atul
    Mittal, Naveen
    Bordoloi, Jayanta K.
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2010, 25 (02): : 62 - 63
  • [28] Accuracy of Choline PET/CT vs Tc 99m Sestamibi SPECT/CT Parathyroid Imaging in Comparison to Histopathology in the Diagnosis of Parathyroid Adenoma: A Meta-Analysis
    Tecson, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S440 - S440
  • [29] Tracheoesophageal groove: reference point detecting descended superior parathyroid adenoma by SPECT/CT
    Kim, Sung
    Intenzo, Charles
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [30] Tc-99m sestamibi planar and SPECT imaging of a retrotracheal parathyroid adenoma
    Vidal-Sicart, S
    Pons, F
    Sabater, L
    Torregrosa, V
    Fuster, D
    Herranz, R
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (04) : 250 - 251