Simulated Fewer-Angle SPECT/CT Imaging Protocol for Parathyroid Adenoma

被引:0
|
作者
Ficke, Jennifer B. [1 ]
Watson, Nora L. [2 ]
Stocker, Derek J. [1 ]
Schlegel, Kevin E. [1 ]
Sahajwalla, Maya C. [1 ]
Adams, Chad C. [3 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Dept Radiol, Bethesda, MD 20814 USA
[2] Walter Reed Natl Mil Med Ctr, Dept Res Programs, Bethesda, MD USA
[3] Eisenhower Army Med Ctr, Dept Radiol, Augusta, GA USA
关键词
SPECT/CT; FASpecT; parathyroid adenoma; RECONSTRUCTION ALGORITHMS; LOCALIZATION; SCINTIGRAPHY; QUALITY;
D O I
10.2967/jnmt.122.264649
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new SPECT/CT protocol for parathyroid imaging detailing fewer image -angle acquisitions (fewer -angle SPECT/CT [FASpecT/CT]) was evaluated for identification of parathyroid adenoma. The motivation for validating this protocol was to be able to use it in the future to decrease patient imaging time in our clinic. Methods: This was a retrospective review of existing data performed as a simulated case control study evaluating 50 parathyroid SPECT/CT scans acquired using the standard 60 -stop protocol and the tested 15 -stop FASpecT protocol acquired using angular sampling software. Agreement on the final interpretations between imaging methods was evaluated using the McNemar test and the Cohen K . Interrater reliability among the 3 readers was described for each method using the Fleiss K interpreted as in the strength -ofagreement guidelines by Landis and Koch. Results: Of the 50 evaluated images, 45 (90%) had concordant final image interpretations between imaging methods. The sensitivity of FASpecT/CT relative to SPECT/CT was 17 of 19 (89.5%; 95% CI, 66.9%-98.7%), and the specificity was 28 of 31 (90.3%; 95% CI, 74.2%-98.0%). Additionally, there was statistically significant substantial agreement between protocols and among readers for each protocol. Conclusion: Adequate diagnostic -quality SPECT/CT images can be acquired using significantly fewer imaging stops given advances in camera quality and processing algorithms such as iterative reconstruction. ize surgical localization ble nonpathologic SPECT/CT added diagnosis planar nation ciency, patient 10 delayed clinics delayed lar will compared approximately
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [1] Fewer-Angle SPECT/CT Blood Pool Imaging for Infection and Inflammation
    Phillips, William T.
    Gorzell, Brandon C.
    Martinez, Robert A.
    Salman, Umber A.
    Cooper, Albert W.
    Stocker, Derek J.
    Adams, Chad C.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2021, 49 (01) : 39 - 43
  • [2] Impact of hybrid SPECT/CT imaging on the detection of single parathyroid adenoma
    Morrison, Antony
    Brennan, Patrick C.
    Reed, Warren
    Pietrzyk, Mariusz
    Schembri, Geoff
    Bailey, Elizabeth
    Roach, Paul
    Evanoff, Michael
    Kench, Peter L.
    MEDICAL IMAGING 2011: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2011, 7966
  • [3] Role of hybrid SPECT-CT fusion imaging in the detection of parathyroid adenoma
    Mittal, B. R.
    Vipul, P.
    Bhattacharya, A.
    Singh, B.
    Bhadada, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S155 - S156
  • [4] SPECT and subtraction imaging of an ectopic parathyroid adenoma
    Serchuk, LS
    Tomas, MB
    Patel, M
    Palestro, CJ
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (07) : 459 - 462
  • [5] Appearance of descended superior parathyroid adenoma on SPECT parathyroid imaging
    Kim, Suk Chul
    Kim, Susanne
    Inabnet, William B.
    Krynyckyi, Borys R.
    Machac, Josef
    Kim, Chun K.
    CLINICAL NUCLEAR MEDICINE, 2007, 32 (02) : 90 - 93
  • [6] Appearance of descended superior parathyroid adenoma on SPECT parathyroid imaging.
    Kim, CK
    Kim, S
    Eskandar, Y
    Krynyckyi, BR
    Zhang, Z
    Knesaurek, K
    Inabnet, WB
    Machac, J
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 326P - 326P
  • [7] Correlation Of SUVmax Obtained From SPECT/CT With Pathology And Laboratory Findings In Imaging Parathyroid Adenoma
    Erdem, A.
    Inanir, A.
    Bozca, B.
    Cayir, D.
    Senlik, S. Demirtas
    Turkmenoglu, T. Taskin
    Dizdar, N. Aydinbelge
    Ozmen, O.
    Cinar, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S365 - S365
  • [8] Contribution of SPECT/CT to preoperative localization of parathyroid adenoma.
    Krausz, Y
    Bettman, L
    Keidar, Z
    Yosilevsky, G
    Guralnik, L
    Even-Sapir, E
    Chisin, R
    Israel, O
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 144P - 144P
  • [9] Ectopic laryngeal parathyroid adenoma detected by SPECT sestamibi imaging
    Moreno, AJ
    Jimenez, CE
    Maredia, R
    Shriver, CD
    Ward, DL
    Hetz, SP
    Simcic, KJ
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (05) : 332 - 333
  • [10] Optimization of CT protocols for thyroid and parathyroid SPECT/CT imaging
    Shalamanov, S.
    Avramova-Cholakova, S.
    Dyakov, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S738 - S738