Bioelectrical impedance analysis for measuring body composition in an outpatient haemodialysis setting: a feasibility study

被引:1
|
作者
Gomes, Kristin [1 ,4 ]
Irwin, Chris [1 ,2 ]
Desbrow, Ben [2 ]
Roberts, Shelley [1 ,2 ,3 ]
机构
[1] Griffith Univ, Sch Hlth Sci & Social Work, Gold Coast Campus, Southport, Qld 4222, Australia
[2] Griffith Univ, Menzies Hlth Inst Queensland, Gold Coast Campus, Southport, Qld 4222, Australia
[3] Gold Coast Hosp & Hlth Serv, Allied Hlth Res, 1 Hosp Blvd, Southport, Qld 4219, Australia
[4] Griffith Univ, Room 2-59,Bldg G40,Gold Coast Campus, Southport, Qld 4222, Australia
关键词
feasibility; bioelectrical impedance; body composition; haemodialysis; malnutrition; MALNUTRITION; MUSCLE; MASS;
D O I
10.33235/rsaj.19.2.56-67
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Aim Clinical guidelines recommend using bioelectrical impedance analysis (BIA) to assess body composition in adults with renal failure on maintenance haemodialysis. This study evaluated the feasibility, acceptability and clinical utility of using BIA with haemodialysis outpatients. Methods Patients attending the haemodialysis outpatient unit at a tertiary public hospital in Australia were consecutively recruited. Participants completed a pre- and post-dialysis BIA measure and satisfaction survey about the measurement process. Primary outcomes pertained to feasibility (recruitment and measurement completion rates). Secondary outcomes included acceptability, assessed via patient satisfaction surveys, and predictive value of BIA for identifying malnutrition according to Subjective Global Assessment (SGA). Continuous variables were presented as mean +/- standard deviation (or median and interquartile range). Binomial logistic regression was performed to determine the predictive value of BIA for identifying malnutrition. Receiver operating characteristic curve analysis was used to evaluate BIA parameters for their ability to discriminate malnourished patients (determined by SGA) from well-nourished patients. Statistical significance was established at p<0.05.<br /> Results A total of 30 of 36 patients approached (83%) consented to participate, with 28 completing at least one BIA measurement and included in data analysis. BIA measurement completion rates were 93% and 87% pre- and postdialysis, respectively. Post-dialysis BIA measures of fat mass index, fat free mass index and skeletal muscle mass most closely reflected SGA-categorised malnutrition. Patients reported high acceptability for BIA, found the process easy, and valued the results. Conclusion BIA use in an outpatient haemodialysis unit is feasible and acceptable to patients, providing valuable objective data to enhance clinical practice.
引用
收藏
页码:56 / 67
页数:70
相关论文
共 50 条
  • [21] BIOELECTRICAL IMPEDANCE ANALYSIS AS A METHOD TO ASSESS BODY-COMPOSITION
    LAWLOR, MR
    CRISMAN, RP
    HODGDON, JA
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 271 - 272
  • [22] Qualitative human body composition analysis assessed with bioelectrical impedance
    Talluri, T
    COLLEGIUM ANTROPOLOGICUM, 1998, 22 (02) : 427 - 432
  • [23] The use of bioelectrical impedance analysis for body composition in epidemiological studies
    A Böhm
    B L Heitmann
    European Journal of Clinical Nutrition, 2013, 67 : S79 - S85
  • [24] Evaluation of bioelectrical impedance analysis as an estimator of moose body composition
    Hundertmark, KJ
    Schwartz, CC
    WILDLIFE SOCIETY BULLETIN, 2002, 30 (03) : 915 - 921
  • [25] Body composition by bioelectrical impedance analysis in renal transplant recipients
    Wong, HS
    Boey, LM
    Morad, Z
    TRANSPLANTATION PROCEEDINGS, 2004, 36 (07) : 2186 - 2187
  • [26] Multifrequency bioelectrical impedance analysis to assess human body composition
    Islam, S
    Kabir, I
    Wahed, MA
    Goran, MI
    Mahalanabis, D
    Fuchs, GJ
    Khaled, MA
    NUTRITION RESEARCH, 1999, 19 (08) : 1179 - 1188
  • [27] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    CLINICAL RESEARCH, 1987, 35 (03): : A775 - A775
  • [28] Applications of bioelectrical impedance analysis for body composition to epidemiologic studies
    Roubenoff, R
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 459 - 462
  • [29] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1987, 45 (04): : 830 - 830
  • [30] Body composition of young laborers:: The results of a bioelectrical impedance analysis
    Ozener, Baris
    Duyar, Izzet
    Atamturk, Derya