摘要
Cardiac index (CI) may be derived from the Fick method, using measured or estimated oxygen consumption (VO2), or from thermodilution. In children, LaFarge VO2 estimates correlate poorly with measured VO2 values. In a large adult cohort, there was only modest correlation between estimated Fick CI (eFick CI) and thermodilution CI (TDCI). We evaluated the extent of agreement between eFick CI using LaFarge estimates of VO2 and TDCI in a pediatric cohort. A retrospective, single-center chart review of patients 3-18 years of age who underwent cardiac catheterization with documented eFick CI and TDCI from 2004 to 2020 included 201 catheterizations from 161 unique patients. The mean patient age at catheterization was 12.2y (SD 4.4y). The most frequent diagnosis was cardiomyopathy, followed by congenital heart disease and pulmonary hypertension. TDCI and eFick CI differed by > 20% in 49% of catheterizations. eFick CI systematically exceeded TDCI by a mean percentage difference of 24% (SD 31%). Higher mean CI ((eFick CI + TDCI)/2) and older age were predictive of greater percent difference between eFick CI and TDCI. For each increase in mean CI by 1.0 L/min/m(2), the expected percent difference in CI increased by 9.9% (p < 0.001). In pediatric patients undergoing cardiac catheterization, eFick CI with LaFarge VO2 systematically exceeds TDCI. The difference between methods is frequently > 20%, which may have clinically significant implications. Discrepancies between eFick CI and TDCI increase at higher mean CI.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 50 条
  • [31] Measurement of cardiac output in infants less than 10 kg: accuracy of femoral artery thermodilution as compared to direct Fick
    SM Tibby
    M Hatherill
    G Jones
    IA Murdoch
    Critical Care, 2 (Suppl 1):
  • [32] Comparison of Accuracy of Estimation of Cardiac Output by Thermodilution Versus the Fick Method Using Measured Oxygen Uptake
    Narang, Nikhil
    Thibodeau, Jennifer T.
    Parker, William F.
    Grodin, Justin L.
    Garg, Sonia
    Tedford, Ryan J.
    Levine, Benjamin D.
    McGuire, Darren K.
    Drazner, Mark H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 176 : 58 - 65
  • [33] Comparison of Accuracy of Estimation of Cardiac Output by Thermodilution Versus the Fick Method Using Measured Oxygen Uptake
    Narang, Nikhil
    Thibodeau, Jennifer T.
    Parker, William F.
    Grodin, Justin L.
    Garg, Sonia
    Tedford, Ryan J.
    Levine, Benjamin D.
    McGuire, Darren K.
    Drazner, Mark H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 176 : 58 - 65
  • [34] Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants
    S. M. Tibby
    M. Hatherill
    M. J. Marsh
    G. Morrison
    D. Anderson
    I. A. Murdoch
    Intensive Care Medicine, 1997, 23 : 987 - 991
  • [35] Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants
    Tibby, SM
    Hatherill, M
    Marsh, MJ
    Morrison, G
    Anderson, D
    Murdoch, IA
    INTENSIVE CARE MEDICINE, 1997, 23 (09) : 987 - 991
  • [36] THERMODILUTION CARDIAC INDEX IS MORE STRONGLY ASSOCIATED WITH 1-YEAR OUTCOMES THAN MEASURED FICK CARDIAC INDEX IN PATIENTS WITH HFREF: IS IT TIME TO ABANDON THE GOLD STANDARD?
    Jain, Nishant
    Perry, Daniel
    Patel, Vaiibhav
    Ashur, Carmel
    Moles, Victor
    Aaronson, Keith D.
    Grafton, Gillian
    Koelling, Todd M.
    Cascino, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 428 - 428
  • [37] COMPARISON OF A MODIFIED FICK METHOD WITH THERMODILUTION FOR DETERMINING CARDIAC-OUTPUT IN CRITICALLY ILL PATIENTS ON MECHANICAL VENTILATION
    LYNCH, J
    KAEMMERER, H
    INTENSIVE CARE MEDICINE, 1990, 16 (04) : 248 - 251
  • [38] How to Reliably Measure Stroke Volume Index in Pulmonary Arterial Hypertension: A Comparison of Thermodilution, Direct and Indirect Fick, and Cardiac MRI
    Baccelli, Andrea
    Gopalan, Deepa
    Davies, Rachel J.
    Haji, Gulammehdi
    Gin-Sing, Wendy
    Howard, Luke S.
    Lo Giudice, Francesco
    LIFE-BASEL, 2025, 15 (01):
  • [39] COMPARISON OF CARDIAC-OUTPUT MEASUREMENT TECHNIQUES - THERMODILUTION, DOPPLER, CO2-REBREATHING AND THE DIRECT FICK METHOD
    ESPERSEN, K
    JENSEN, EW
    ROSENBORG, D
    THOMSEN, JK
    ELIASEN, K
    OLSEN, NV
    KANSTRUP, IL
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (02) : 245 - 251
  • [40] Comparison of impedance cardiography to direct fick and echocardiographic measurement of cardiac index in children.
    Lindblade, C
    Schamberger, M
    Ebenroth, E
    Batra, A