The Estimated Fick Method Systematically Over-Estimates Cardiac Index Compared to Thermodilution in Children

被引:1
|
作者
Lawson, Andrew A. [1 ]
Tannous, Paul [1 ]
Laternser, Christina [2 ]
Migally, Karl [1 ]
机构
[1] Northwestern Univ, Ann & Robert H Lurie Childrens Hosp Chicago, Dept Pediat, Div Cardiol,Feinberg Sch Med, 225 E Chicago Ave,Box 21, Chicago, IL 60611 USA
[2] Ann & Robert H Lurie Childrens Hosp Chicago, Ctr Cardiovasc Innovat, Chicago, IL USA
关键词
Cardiac index; Thermodilution; Estimated Fick method; LaFarge equation; CONGENITAL HEART-DISEASE; OXYGEN-CONSUMPTION; OUTPUT; VALIDITY; EQUATION; ERRORS;
D O I
10.1007/s00246-024-03491-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac index (CI) may be derived from the Fick method, using measured or estimated oxygen consumption (VO2), or from thermodilution. In children, LaFarge VO2 estimates correlate poorly with measured VO2 values. In a large adult cohort, there was only modest correlation between estimated Fick CI (eFick CI) and thermodilution CI (TDCI). We evaluated the extent of agreement between eFick CI using LaFarge estimates of VO2 and TDCI in a pediatric cohort. A retrospective, single-center chart review of patients 3-18 years of age who underwent cardiac catheterization with documented eFick CI and TDCI from 2004 to 2020 included 201 catheterizations from 161 unique patients. The mean patient age at catheterization was 12.2y (SD 4.4y). The most frequent diagnosis was cardiomyopathy, followed by congenital heart disease and pulmonary hypertension. TDCI and eFick CI differed by > 20% in 49% of catheterizations. eFick CI systematically exceeded TDCI by a mean percentage difference of 24% (SD 31%). Higher mean CI ((eFick CI + TDCI)/2) and older age were predictive of greater percent difference between eFick CI and TDCI. For each increase in mean CI by 1.0 L/min/m(2), the expected percent difference in CI increased by 9.9% (p < 0.001). In pediatric patients undergoing cardiac catheterization, eFick CI with LaFarge VO2 systematically exceeds TDCI. The difference between methods is frequently > 20%, which may have clinically significant implications. Discrepancies between eFick CI and TDCI increase at higher mean CI.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 50 条
  • [21] OVERESTIMATION OF FICK CARDIAC-OUTPUT BY THERMODILUTION METHOD IN PATIENTS WITH SEVERE TRICUSPID REGURGITATION
    GOLDENBERG, IF
    OCHI, RP
    EMERY, RW
    MADISON, JD
    HUNN, D
    NELSON, RR
    VANTASSEL, RA
    LEW, BT
    ROGERS, JW
    AROM, KV
    ARNAR, O
    GOBEL, FL
    PRITZKER, MRR
    CRITICAL CARE MEDICINE, 1988, 16 (04) : 428 - 428
  • [22] COMPARING MEASUREMENTS OF CARDIAC-OUTPUT BY FICK PRINCIPLE AND THERMODILUTION METHOD AT REST AND EXERCISE
    SCHLEHE, H
    MATTHYS, H
    HARICH, B
    NISSEN, H
    KONIETZKO, N
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1973, 103 (50) : 1773 - 1775
  • [23] THERMODILUTION CARDIAC OUTPUTS USING ROOM AND ICE TEMPERATURE INJECTATE - COMPARISON WITH THE FICK METHOD
    DAILY, EK
    MERSCH, J
    HEART & LUNG, 1987, 16 (03): : 294 - 300
  • [24] THERMODILUTION MEASUREMENT OF CARDIAC-OUTPUT - STUDY IN DOGS COMPARING DIRECT FICK WITH AN AUTOMATED THERMODILUTION METHOD (FISCHER CARDIAC-OUTPUT COMPUTER)
    ARFORS, KE
    MALMBERG, P
    ACTA CHIRURGICA SCANDINAVICA, 1972, 138 (08): : 761 - 764
  • [25] COMPARISON OF CARDIAC OUTPUT(CO) BY NONINVASIVE DOPPLER, THERMODILUTION AND FICK METHOD IN NEWBORN(NB) PIGLETS
    WELCH, E
    SUGUIHARA, C
    DUARA, S
    BANDSTRA, E
    FERRER, P
    BANCALARI, E
    PEDIATRIC RESEARCH, 1991, 29 (04) : A249 - A249
  • [26] Cardiac output measurement by pulse dye densitometry: a comparison with the Fick's principle and thermodilution method
    Frank Bremer
    Albert Schiele
    Klaus Tschaikowsky
    Intensive Care Medicine, 2002, 28 : 399 - 405
  • [27] Cardiac output measurement by pulse dye densitometry: a comparison with the Fick's principle and thermodilution method
    Bremer, F
    Schiele, A
    Tschaikowsky, K
    INTENSIVE CARE MEDICINE, 2002, 28 (04) : 399 - 405
  • [28] Accuracy of Noninvasive Estimated Continuous Cardiac Output (esCCO) Compared to Thermodilution Cardiac Output: A Pilot Study in Cardiac Patients
    Ball, Timothy R.
    Tricinella, Anthony P.
    Kimbrough, Alex
    Luna, Sarah
    Gloyna, David F.
    Villamaria, Frank J.
    Culp, William C., Jr.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) : 1128 - 1132
  • [29] ASSESSMENT OF A CATHETER-TIP THERMODILUTION METHOD FOR CARDIAC OUTPUT DETERMINATION IN MAN IN COMPARISON WITH DIRECT FICK METHOD
    KHALIL, HH
    WONG, M
    RAPAPORT, E
    CIRCULATION, 1965, 32 (4S2) : 124 - &
  • [30] Cardiac index monitoring by femoral arterial thermodilution after cardiac surgery in children
    Gil-Anton, Javier
    Lopez-Bayon, Julio
    Lopez-Fernandez, Yolanda
    Morteruel, Elvira
    Perez-Estevez, Elena
    Lopez-Herce, Jess
    JOURNAL OF CRITICAL CARE, 2014, 29 (06) : 1132.e1 - 1132.e4