摘要
Cardiac index (CI) may be derived from the Fick method, using measured or estimated oxygen consumption (VO2), or from thermodilution. In children, LaFarge VO2 estimates correlate poorly with measured VO2 values. In a large adult cohort, there was only modest correlation between estimated Fick CI (eFick CI) and thermodilution CI (TDCI). We evaluated the extent of agreement between eFick CI using LaFarge estimates of VO2 and TDCI in a pediatric cohort. A retrospective, single-center chart review of patients 3-18 years of age who underwent cardiac catheterization with documented eFick CI and TDCI from 2004 to 2020 included 201 catheterizations from 161 unique patients. The mean patient age at catheterization was 12.2y (SD 4.4y). The most frequent diagnosis was cardiomyopathy, followed by congenital heart disease and pulmonary hypertension. TDCI and eFick CI differed by > 20% in 49% of catheterizations. eFick CI systematically exceeded TDCI by a mean percentage difference of 24% (SD 31%). Higher mean CI ((eFick CI + TDCI)/2) and older age were predictive of greater percent difference between eFick CI and TDCI. For each increase in mean CI by 1.0 L/min/m(2), the expected percent difference in CI increased by 9.9% (p < 0.001). In pediatric patients undergoing cardiac catheterization, eFick CI with LaFarge VO2 systematically exceeds TDCI. The difference between methods is frequently > 20%, which may have clinically significant implications. Discrepancies between eFick CI and TDCI increase at higher mean CI.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 50 条
  • [1] The Fick Method With Lafarge Estimates of Oxygen Consumption Systematically Over-Estimates Cardiac Index When Compared to Thermodilution in Children
    Lawson, Andrew A.
    Tannous, Paul
    Laternser, Christina
    Migally, Karl
    CIRCULATION, 2022, 146
  • [2] CONTINUOUS FICK CARDIAC-OUTPUT COMPARED TO THERMODILUTION CARDIAC-OUTPUT
    DAVIES, GG
    JEBSON, PJR
    GLASGOW, BM
    HESS, DR
    CRITICAL CARE MEDICINE, 1986, 14 (10) : 881 - 885
  • [3] Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle
    Pauli, C
    Fakler, U
    Genz, T
    Hennig, M
    Lorenz, HP
    Hess, J
    INTENSIVE CARE MEDICINE, 2002, 28 (07) : 947 - 952
  • [4] Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle
    C. Pauli
    U. Fakler
    T. Genz
    M. Hennig
    H.-P. Lorenz
    J. Hess
    Intensive Care Medicine, 2002, 28 : 947 - 952
  • [5] Continuous measurement of cardiac output by the Fick principle in infants and children: Comparison with the thermodilution method
    Wippermann, CF
    Huth, RG
    Schmidt, FX
    Thul, J
    Betancor, M
    Schranz, D
    INTENSIVE CARE MEDICINE, 1996, 22 (05) : 467 - 471
  • [6] ESTIMATION OF CARDIAC INDEX IN CHILDREN USING A MODIFIED FICK METHOD
    RUDLOFF, AM
    WITTE, MK
    SPECTOR, ML
    CIRCULATION, 1986, 74 (04) : 149 - 149
  • [7] Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method
    Engoren, M
    Barbee, D
    AMERICAN JOURNAL OF CRITICAL CARE, 2005, 14 (01) : 40 - 45
  • [8] Indirect Fick and Thermodilution Cardiac Output Measurements Have Significant Variance Compared to Direct Fick in LVAD Patients
    Azih, N. I.
    Read, J. M.
    Jackson, G.
    Inampudi, C.
    Pope, N. H.
    Witer, L. J.
    Tedford, R. J.
    Houston, B. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S214 - S214
  • [9] DETERMINATION OF CARDIAC-OUTPUT BY THERMODILUTION AND ITS CORRELATION WITH FICK METHOD
    BAEZAR, H
    CHAMORROS, G
    LANASZ, F
    ESCOBARS, E
    REVISTA MEDICA DE CHILE, 1977, 105 (11) : 868 - 868
  • [10] MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION - CORRELATION WITH DIRECT FICK METHOD
    BAEZA, H
    CHAMORRO, G
    LANAS, F
    ESCOBAR, E
    REVISTA MEDICA DE CHILE, 1978, 106 (10) : 784 - 787