Compatibility of a New Ocular Surface Dye with Disposable and Bi-Weekly Soft Contact Lenses: An Experimental Study

被引:2
|
作者
Troisi, Mario [1 ]
Caruso, Ciro [2 ]
D'Andrea, Luca [1 ,3 ]
Rinaldi, Michele [1 ]
Piscopo, Raffaele [1 ]
Troisi, Salvatore [4 ]
Costagliola, Ciro [1 ]
机构
[1] Univ Naples Federico II, Dept Neurosci Reprod & Odontostomatol Sci, Eye Clin, Via Pansini n 5, I-80131 Naples, Italy
[2] Pellegrini Hosp, Corneal Transplant Ctr, Via Portamedina Pignasecca,41, I-80127 Naples, Italy
[3] Univ Naples Federico II, Publ Hlth Dept, Via Pansini n 5, I-80131 Naples, Italy
[4] Salerno Hosp Univ, Ophthalmol Unit, I-84100 Salerno, Italy
来源
LIFE-BASEL | 2024年 / 14卷 / 06期
关键词
corneal staining; riboflavin-based dye; contact lenses examination; ocular surface dye; conjunctival staining; LISSAMINE GREEN; ROSE-BENGAL; TIGHT JUNCTION; CORNEAL; FLUORESCEIN;
D O I
10.3390/life14060653
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ocular surface staining for assessing corneal and conjunctival epithelium integrity is typically conducted using fluorescein, lissamine green, or rose Bengal dyes. Recently, a novel vital dye, REmark (R), based on riboflavin, has been proposed for ocular surface examination. In the management of corneal and ocular surface diseases (OSD), the use of contact lenses is integral to therapeutic strategies. This study explores the compatibility of REmark (R) with four different types of disposable or bi-weekly soft contact lenses. Morphological variations observed under stereomicroscopy and ultraviolet (UV) ray transmittance in the visible spectrum (VIS) were evaluated at 2 and 4 h post-immersion of the contact lenses in both the original fluid and the new dye. The findings indicate no significant differences between the group treated with the original liquid and those immersed in REmark (R), except for a yellow hue observed in the latter group, which dissipates after 8 h in physiological solution. This study highlights the potential of utilizing the new vital dye for ophthalmologic examinations even in the presence of applied soft contact lenses, offering a promising avenue for improved diagnostic practices and patient comfort.
引用
收藏
页数:12
相关论文
共 25 条
  • [21] In vitro compatibility study of a new preservative-free multidose 0.6% bilastine eye drop formulation containing sodium hyaluronate with soft and gas rigid permeable contact lenses
    Rey, Eider Arana
    Cortes, Tatiana Suarez
    Gonzalo, Ana
    Victoriano, Noelia Andollo
    Prat, Ines Torrens
    Zazpe, Arturo
    Hernandez, Gonzalo
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [22] COMPARATIVE-STUDY OF CORNEAL EPITHELIAL SURFACE WITH SCANNING MICROSCOPE AFTER WEARING OF HARD AND SOFT CONTACT-LENSES
    FRANCOIS, J
    VICTORIATRONCOSO, V
    DHAENENS, J
    ANNALES D OCULISTIQUE, 1977, 210 (09): : 659 - 666
  • [23] Evaluation of Ocular Surface Characteristics in Dry Eye Disease With and Without Soft Contact Lens Wear: A Comparative Study
    Yang, Tingting
    Ma, Baikai
    Xie, Jianyang
    Zhou, Yifan
    Liu, Rongjun
    Duan, Hongyu
    Zhao, Yitian
    Qi, Hong
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (09): : 377 - 383
  • [24] Daytime Changes in Tear Film Parameters and Visual Acuity with New-Generation Daily Disposable Silicone Hydrogel Contact Lenses-A Double-Masked Study in Symptomatic Subjects
    Macedo-de-Araujo, Rute J.
    Rico-del-Viejo, Laura
    Martin-Montanez, Vicente
    Queiros, Antonio
    Gonzalez-Meijome, Jose M.
    VISION, 2024, 8 (01)
  • [25] Evaluation of soft tissue reactions at the interface of titanium limited contact dynamic compression plate implants with different surface treatments: An experimental sheep study
    Ungersbock, A
    Pohler, OEM
    Perren, SM
    BIOMATERIALS, 1996, 17 (08) : 797 - 806