Compatibility of a New Ocular Surface Dye with Disposable and Bi-Weekly Soft Contact Lenses: An Experimental Study

被引:2
|
作者
Troisi, Mario [1 ]
Caruso, Ciro [2 ]
D'Andrea, Luca [1 ,3 ]
Rinaldi, Michele [1 ]
Piscopo, Raffaele [1 ]
Troisi, Salvatore [4 ]
Costagliola, Ciro [1 ]
机构
[1] Univ Naples Federico II, Dept Neurosci Reprod & Odontostomatol Sci, Eye Clin, Via Pansini n 5, I-80131 Naples, Italy
[2] Pellegrini Hosp, Corneal Transplant Ctr, Via Portamedina Pignasecca,41, I-80127 Naples, Italy
[3] Univ Naples Federico II, Publ Hlth Dept, Via Pansini n 5, I-80131 Naples, Italy
[4] Salerno Hosp Univ, Ophthalmol Unit, I-84100 Salerno, Italy
来源
LIFE-BASEL | 2024年 / 14卷 / 06期
关键词
corneal staining; riboflavin-based dye; contact lenses examination; ocular surface dye; conjunctival staining; LISSAMINE GREEN; ROSE-BENGAL; TIGHT JUNCTION; CORNEAL; FLUORESCEIN;
D O I
10.3390/life14060653
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ocular surface staining for assessing corneal and conjunctival epithelium integrity is typically conducted using fluorescein, lissamine green, or rose Bengal dyes. Recently, a novel vital dye, REmark (R), based on riboflavin, has been proposed for ocular surface examination. In the management of corneal and ocular surface diseases (OSD), the use of contact lenses is integral to therapeutic strategies. This study explores the compatibility of REmark (R) with four different types of disposable or bi-weekly soft contact lenses. Morphological variations observed under stereomicroscopy and ultraviolet (UV) ray transmittance in the visible spectrum (VIS) were evaluated at 2 and 4 h post-immersion of the contact lenses in both the original fluid and the new dye. The findings indicate no significant differences between the group treated with the original liquid and those immersed in REmark (R), except for a yellow hue observed in the latter group, which dissipates after 8 h in physiological solution. This study highlights the potential of utilizing the new vital dye for ophthalmologic examinations even in the presence of applied soft contact lenses, offering a promising avenue for improved diagnostic practices and patient comfort.
引用
收藏
页数:12
相关论文
共 25 条
  • [11] Effect of different tinted soft contact lenses on the tear quality and ocular surface properties
    Hsu, Min-Yen
    Wang, Yu-Ping
    Hong, Pei-Yu
    Chen, Pei-Ying
    Chen, Connie
    INTERNATIONAL JOURNAL OF OPTOMECHATRONICS, 2021, 15 (01) : 10 - 18
  • [12] Surface temperature change in soft contact lenses: an in vitro study
    Wong, Stephanie
    Lum, Edward
    Cornella, Aniol Planaguma
    Murphy, Paul J.
    Jones, Lyndon William
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [13] Assessment of ocular surface response to tinted soft contact lenses with different characteristics and pigment location
    Hsu, Min-Yen
    Hong, Pei-Yu
    Liou, Jyh-Cheng
    Wang, Yu-Ping
    Chen, Connie
    INTERNATIONAL JOURNAL OF OPTOMECHATRONICS, 2020, 14 (01) : 119 - 130
  • [14] Effects of extended-wear soft contact lenses on the ocular surface and central corneal thickness
    Gürdal, C
    Aydin, S
    Kirimlioglu, H
    Toprak, E
    Sengör, T
    OPHTHALMOLOGICA, 2003, 217 (05) : 329 - 336
  • [15] A 12-month Prospective Study of Tear Osmolarity in Contact Lens Wearers Refitted with Daily Disposable Soft Contact Lenses
    Garaszczuk, Izabela Katarzyna
    Mousavi, Maryam
    Szczesna-Iskander, Dorota H.
    Cervino, Alejandro
    Iskander, D. Robert
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (03) : 178 - 185
  • [16] The disposable bandage soft contact lenses therapy and anterior segment optical coherence tomography for management of ocular graft-versus-host disease
    Yi-Chen Sun
    Yoshihiro Inamoto
    Ruikang K. Wang
    Stephanie J. Lee
    Kai-Feng Hung
    Tueng T. Shen
    BMC Ophthalmology, 21
  • [17] The disposable bandage soft contact lenses therapy and anterior segment optical coherence tomography for management of ocular graft-versus-host disease
    Sun, Yi-Chen
    Inamoto, Yoshihiro
    Wang, Ruikang K.
    Lee, Stephanie J.
    Hung, Kai-Feng
    Shen, Tueng T.
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [18] Correction to: The disposable bandage soft contact lenses therapy and anterior segment optical coherence tomography for management of ocular graft-versus-host disease
    Yi-Chen Sun
    Yoshihiro Inamoto
    Ruikang K. Wang
    Stephanie J. Lee
    Kai-Feng Hung
    Tueng T. Shen
    BMC Ophthalmology, 22
  • [19] Characterization of surface roughness of new nanophotonic soft contact lenses using lacunarity and AFM method
    Mitrovic, Aleksandra
    Bojovic, Bozica
    Stamenkovic, Dragomir
    Popovic, Dejana
    HEMIJSKA INDUSTRIJA, 2018, 72 (03) : 157 - 166
  • [20] The disposable bandage soft contact lenses therapy and anterior segment optical coherence tomography for management of ocular graft-versus-host disease (vol 21, 271, 2021)
    Sun, Yi-Chen
    Inamoto, Yoshihiro
    Wang, Ruikang K.
    Lee, Stephanie J.
    Hung, Kai-Feng
    Shen, Tueng T.
    BMC OPHTHALMOLOGY, 2022, 22 (01)