Hemodynamic Insights into Combined Fractional Flow Reserve and Instantaneous Wave-Free Ratio Assessment Through Quantitative [15O]H2O PET Myocardial Perfusion Imaging

被引:1
|
作者
de Winter, Ruben W. [1 ]
van Diemen, Pepijn A. [1 ]
Schumacher, Stefan P. [1 ]
Jukema, Ruurt A. [1 ]
Somsen, Yvemarie B. O. [1 ]
Hoek, Roel [1 ]
van Rossum, Albert C. [1 ]
Twisk, Jos W. R. [2 ]
de Waard, Guus A. [1 ]
Nap, Alexander [1 ]
Raijmakers, Pieter G. [3 ]
Driessen, Roel S. [1 ]
Knaapen, Paul [1 ]
Danad, Ibrahim [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Cardiol, Amsterdam UMC, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Epidemiol & Data Sci, Amsterdam UMC, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Radiol Nucl Med & PET Res, Amsterdam UMC, Amsterdam, Netherlands
关键词
fractional flow reserve; instantaneous wave-free ratio; O-15]H2O PET; absolute myocardial perfusion; P-D/P-A; BLOOD-FLOW; DISCORDANCE; SEVERITY; APPROXIMATE; ANGIOGRAPHY; INDEXES; HEART; IFR;
D O I
10.2967/jnumed.123.265973
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In patients evaluated for obstructive coronary artery disease (CAD), guidelines recommend using either fractional flow reserve (FFR) or instantaneous wave-free ratio (iFR) to guide coronary revascularization decision-making. The hemodynamic significance of lesions with discordant FFR and iFR measurements is debated. This study compared [O-15]H2O PET-derived absolute myocardial perfusion between vessels with concordant and discordant FFR and iFR measurements. Methods: We included 197 patients suspected of obstructive CAD who had undergone [O-15]H2O PET perfusion imaging and combined FFR/iFR interrogation in 468 vessels. Resting myocardial blood flow (MBF), hyperemic MBF, and coronary flow reserve (CFR) were compared among 4 groups: FFR low/iFR low (n = 79), FFR high/iFR low (n = 22), FFR low/iFR high (n = 22), and FFR high/iFR high (n = 345). Predefined [O-15]H2O PET thresholds for ischemia were 2.3 mL<middle dot>min(-1)<middle dot>g(-1) or less for hyperemic MBF and 2.5 or less for CFR. Results: Hyperemic MBF was lower in the concordant low (2.09 +/- 0.67 mL<middle dot>min(-1)<middle dot>g(-1)), FFR high/iFR low (2.41 +/- 0.80 mL<middle dot>min(-1)<middle dot>g(-1)), and FFR low/iFR high (2.40 +/- 0.69 mL<middle dot>min(-1)<middle dot>g(-1)) groups compared with the concordant high group (2.91 +/- 0.84 mL<middle dot>min(-1)<middle dot>g(-1)) (P < 0.001, P = 0.004, and P < 0.001, respectively). A lower CFR was observed in the concordant low (2.37 +/- 0.76) and FFR high/iFR low (2.64 +/- 0.84) groups compared with the concordant high group (3.35 +/- 1.07, P < 0.01 for both). However, for vessels with either low FFR or low iFR, quantitative hyperemic MBF and CFR values exceeded the ischemic threshold in 38% and 49%, respectively. In addition, resting MBF exhibited a negative correlation with iFR (P < 0.001) and was associated with FFR low/iFR high discordance compared with concordant low FFR/low iFR measurements, independent of clinical and angiographic characteristics, as well as hyperemic MBF (odds ratio [OR], 0.41; 95% CI, 0.26-0.65; P < 0.001). Conclusion: We found reduced myocardial perfusion in vessels with concordant low and discordant FFR/iFR measurements. However, FFR/iFR combinations often inaccurately classified vessels as either ischemic or nonischemic when compared with hyperemic MBF and CFR. Furthermore, a lower resting MBF was associated with a higher iFR and the occurrence of FFR low/iFR high discordance. Our study showed that although combined FFR/iFR assessment can be useful to estimate the hemodynamic significance of coronary lesions, these pressure-derived indices provide a limited approximation of [O-15]H2O PET-derived quantitative myocardial perfusion as the physiologic standard of CAD severity.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [1] Fractional flow reserve, instantaneous wave-free ratio, and resting Pd/Pa compared with [15O]H2O positron emission tomography myocardial perfusion imaging: a PACIFIC trial sub-study
    de Waard, Guus A.
    Danad, Ibrahim
    Petraco, Ricardo
    Driessen, Roel S.
    Raijmakers, Pieter G.
    Teunissen, Paul F.
    van de Ven, Peter M.
    van Leeuwen, Maarten A. H.
    Nap, Alexander
    Harms, Hendrik J.
    Lammertsma, Adriaan A.
    Davies, Justin E.
    Knaapen, Paul
    van Royen, Niels
    EUROPEAN HEART JOURNAL, 2018, 39 (46) : 4072 - +
  • [2] Impact of Revascularization on Fractional Flow Reserve and Absolute Myocardial Blood Flow as Assessed by Serial [15O]H2O PET Imaging
    Driessen, Roel
    Danad, Ibrahim
    Stuijfzand, Wijnand
    Schumacher, Stefan
    Lammertsma, Adriaan
    van Rossum, Albert
    van Royen, Niels
    Raijmakers, Pieter
    Knaapen, Paul
    CIRCULATION, 2017, 136
  • [3] CONCORDANT LOW AND DISCORDANT FRACTIONAL FLOW RESERVE AND INSTANTANEOUS WAVE-FREE RATIO MEASUREMENTS ARE ASSOCIATED WITH REDUCED MYOCARDIAL PERFUSION:A COMPARISON BETWEEN PRESSURE RATIO MEASUREMENTS AND 15O-WATER PET PERFUSION IMAGING
    De Winter, Ruben Willem
    Van Diemen, Pepijn
    Schumacher, Stefan
    Jukema, Ruurt
    Somsen, Yvemarie
    Bom, Michiel
    Everaars, Henk
    van Rossum, Albert
    Verouden, Niels
    Raijmakers, Pieter
    Nap, Alexander
    Driessen, Roel
    Danad, Ibrahim
    Knaapen, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1196 - 1196
  • [4] IMPACT OF REVASCULARIZATION ON ABSOLUTE MYOCARDIAL BLOOD FLOW AS ASSESSED BY SERIAL [15O]H2O PET IMAGING: A COMPARISON WITH FRACTIONAL FLOW RESERVE
    Driessen, Roel
    Danad, Ibrahim
    Stuijfzand, Wijnand
    Schumacher, Stefan
    Knuuti, Juhani
    Lammertsma, Adriaan
    van Rossum, Albert
    Van Royen, Niels
    Raijmakers, Pieter
    Knaapen, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1480 - 1480
  • [5] Comparison of the diagnostic accuracy of instantaneous wave-free ratio and fractional flow reserve for the detection of myocardial ischemia as defined by myocardial perfusion imaging
    Hoshino, K.
    Tanaka, N.
    Hokama, Y.
    Sakoda, K.
    Murata, N.
    Matsumoto, C.
    Yamashita, J.
    Hida, S.
    Chikamori, T.
    Yamashina, A.
    EUROPEAN HEART JOURNAL, 2016, 37 : 607 - 607
  • [6] Pulmonary embolism as an incidental finding in [15O]H2O PET/CT myocardial perfusion imaging
    Nagel, Julie Loft
    Tolbod, Lars Poulsen
    Harms, Hendrik Johannes
    Gormsen, Lars Christian
    Madsen, Michael Alle
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 52 (01) : 368 - 369
  • [7] The Challenges of Measuring Coronary Flow Reserve Comparisons of Doppler and Thermodilution to [15O]H2O PET Perfusion
    Kern, Morton J.
    Seto, Arnold H.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (20) : 2055 - 2057
  • [8] Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [15O]H2O PET Imaging
    Danad, Ibrahim
    Uusitalo, Valtteri
    Kero, Tanja
    Saraste, Antti
    Raijmakers, Pieter G.
    Lammertsma, Adriaan A.
    Heymans, Martijn W.
    Kajander, Sami A.
    Pietilae, Mikko
    James, Stefan
    Soerensen, Jens
    Knaapen, Paul
    Knuuti, Juhani
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (14) : 1464 - 1475
  • [9] Concordant low and discordant fractional flow reserve and instantaneous wave-free ratio measurements are associated with reduced myocardial perfusion
    De Winter, R. W.
    Van Diemen, P. A.
    Schumacher, S. P.
    Jukema, R. A.
    Somsen, Y. B. O.
    Born, M. J.
    Everaars, H.
    Van Rossum, A. C.
    Verouden, N. J.
    Raijmakers, P. G.
    Nap, A.
    Driessen, R. S.
    Danad, I.
    Knaapen, P.
    EUROPEAN HEART JOURNAL, 2022, 43 : 2018 - 2018
  • [10] Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: comparison with the results of [15O]H2O PET
    Yoshinori Ito
    Chietsugu Katoh
    Kazuyuki Noriyasu
    Yuji Kuge
    Hideto Furuyama
    Koichi Morita
    Tetsuro Kohya
    Akira Kitabatake
    Nagara Tamaki
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 281 - 287