Hemodynamic Insights into Combined Fractional Flow Reserve and Instantaneous Wave-Free Ratio Assessment Through Quantitative [15O]H2O PET Myocardial Perfusion Imaging

被引:1
|
作者
de Winter, Ruben W. [1 ]
van Diemen, Pepijn A. [1 ]
Schumacher, Stefan P. [1 ]
Jukema, Ruurt A. [1 ]
Somsen, Yvemarie B. O. [1 ]
Hoek, Roel [1 ]
van Rossum, Albert C. [1 ]
Twisk, Jos W. R. [2 ]
de Waard, Guus A. [1 ]
Nap, Alexander [1 ]
Raijmakers, Pieter G. [3 ]
Driessen, Roel S. [1 ]
Knaapen, Paul [1 ]
Danad, Ibrahim [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Cardiol, Amsterdam UMC, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Epidemiol & Data Sci, Amsterdam UMC, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Radiol Nucl Med & PET Res, Amsterdam UMC, Amsterdam, Netherlands
关键词
fractional flow reserve; instantaneous wave-free ratio; O-15]H2O PET; absolute myocardial perfusion; P-D/P-A; BLOOD-FLOW; DISCORDANCE; SEVERITY; APPROXIMATE; ANGIOGRAPHY; INDEXES; HEART; IFR;
D O I
10.2967/jnumed.123.265973
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In patients evaluated for obstructive coronary artery disease (CAD), guidelines recommend using either fractional flow reserve (FFR) or instantaneous wave-free ratio (iFR) to guide coronary revascularization decision-making. The hemodynamic significance of lesions with discordant FFR and iFR measurements is debated. This study compared [O-15]H2O PET-derived absolute myocardial perfusion between vessels with concordant and discordant FFR and iFR measurements. Methods: We included 197 patients suspected of obstructive CAD who had undergone [O-15]H2O PET perfusion imaging and combined FFR/iFR interrogation in 468 vessels. Resting myocardial blood flow (MBF), hyperemic MBF, and coronary flow reserve (CFR) were compared among 4 groups: FFR low/iFR low (n = 79), FFR high/iFR low (n = 22), FFR low/iFR high (n = 22), and FFR high/iFR high (n = 345). Predefined [O-15]H2O PET thresholds for ischemia were 2.3 mL<middle dot>min(-1)<middle dot>g(-1) or less for hyperemic MBF and 2.5 or less for CFR. Results: Hyperemic MBF was lower in the concordant low (2.09 +/- 0.67 mL<middle dot>min(-1)<middle dot>g(-1)), FFR high/iFR low (2.41 +/- 0.80 mL<middle dot>min(-1)<middle dot>g(-1)), and FFR low/iFR high (2.40 +/- 0.69 mL<middle dot>min(-1)<middle dot>g(-1)) groups compared with the concordant high group (2.91 +/- 0.84 mL<middle dot>min(-1)<middle dot>g(-1)) (P < 0.001, P = 0.004, and P < 0.001, respectively). A lower CFR was observed in the concordant low (2.37 +/- 0.76) and FFR high/iFR low (2.64 +/- 0.84) groups compared with the concordant high group (3.35 +/- 1.07, P < 0.01 for both). However, for vessels with either low FFR or low iFR, quantitative hyperemic MBF and CFR values exceeded the ischemic threshold in 38% and 49%, respectively. In addition, resting MBF exhibited a negative correlation with iFR (P < 0.001) and was associated with FFR low/iFR high discordance compared with concordant low FFR/low iFR measurements, independent of clinical and angiographic characteristics, as well as hyperemic MBF (odds ratio [OR], 0.41; 95% CI, 0.26-0.65; P < 0.001). Conclusion: We found reduced myocardial perfusion in vessels with concordant low and discordant FFR/iFR measurements. However, FFR/iFR combinations often inaccurately classified vessels as either ischemic or nonischemic when compared with hyperemic MBF and CFR. Furthermore, a lower resting MBF was associated with a higher iFR and the occurrence of FFR low/iFR high discordance. Our study showed that although combined FFR/iFR assessment can be useful to estimate the hemodynamic significance of coronary lesions, these pressure-derived indices provide a limited approximation of [O-15]H2O PET-derived quantitative myocardial perfusion as the physiologic standard of CAD severity.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [31] Clinical impact of quantitative [15O] H2O PET/CT myocardial perfusion imaging on decision-making regarding invasive management of coronary artery disease
    Promteangtrong, Chetsadaporn
    Jantarato, Attapon
    Kunawudhi, Anchisa
    Kiatkittikul, Peerapon
    Siripongsatian, Dheeratama
    Boonkawin, Natphimol
    Chotipanich, Chanisa
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (04) : 1887 - 1899
  • [32] Hyperemic FFR and basal iFR have a similar diagnostic accuracy when compared to [15O]H2O PET perfusion imaging defined myocardial blood flow
    de Waard, Guus
    Danad, Ibrahim
    Petraco, Ricardo
    Teunissen, Paul
    van de Hoef, Tim
    Raijmakers, Pieter
    Lammertsma, Adriaan
    Davies, Justin
    Knaapen, Paul
    van Royen, Niels
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [33] Assessment of myocardial blood flow using 3D [15O]-H2O PET/CT: Analytic or iterative reconstruction?
    Arnould, Jean-Simon
    Bailliez, Alban
    Blaire, Tanguy
    Agostini, Denis
    Abbas, Ahmed
    Manrique, Alain
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [34] Repeatability of [15O]H2O PET imaging for lower extremity skeletal muscle perfusion: a test–retest study
    Nana Louise Christensen
    Jens Sørensen
    Kirsten Bouchelouche
    Michael Alle Madsen
    Christian Selmer Buhl
    Lars Poulsen Tolbod
    EJNMMI Research, 14
  • [35] Comparison between quantitative cardiac magnetic resonance perfusion imaging and [15O]H2O positron emission tomography
    Everaars, Henk
    van Diemen, Pepijn A.
    Bom, Michiel J.
    Schumacher, Stefan P.
    de Winter, Ruben W.
    van de Ven, Peter M.
    Raijmakers, Pieter G.
    Lammertsma, Adriaan A.
    Hofman, Mark B. M.
    van Der Geest, Rob J.
    Gotte, Marco J.
    van Rossum, Albert C.
    Nijveldt, Robin
    Danad, Ibrahim
    Driessen, Roel S.
    Knaapen, Paul
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (07) : 1688 - 1697
  • [36] Correction to: A retrospective evaluation of Bayesian-penalized likelihood reconstruction for [15O]H2O myocardial perfusion imaging
    Reetta Siekkinen
    Chunlei Han
    Teemu Maaniitty
    Mika Teräs
    Juhani Knuuti
    Antti Saraste
    Jarmo Teuho
    Journal of Nuclear Cardiology, 2023, 30 : 1253 - 1253
  • [37] Comparison between quantitative cardiac magnetic resonance perfusion imaging and [15O]H2O positron emission tomography
    Henk Everaars
    Pepijn A. van Diemen
    Michiel J. Bom
    Stefan P. Schumacher
    Ruben W. de Winter
    Peter M. van de Ven
    Pieter G. Raijmakers
    Adriaan A. Lammertsma
    Mark B. M. Hofman
    Rob J. van der Geest
    Marco J. Götte
    Albert C. van Rossum
    Robin Nijveldt
    Ibrahim Danad
    Roel S. Driessen
    Paul Knaapen
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 1688 - 1697
  • [38] Doppler Flow Velocity and Thermodilution to Assess Coronary Flow Reserve A Head-to-Head Comparison With [15O]H2O PET
    Everaars, Henk
    de Waard, Guus A.
    Driessen, Roel S.
    Danad, Ibrahim
    van de Ven, Peter M.
    Raijmakers, Pieter G.
    Lammertsma, Adriaan A.
    van Rossum, Albert C.
    Knaapen, Paul
    van Royen, Niels
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (20) : 2044 - 2054
  • [39] Determining Hemodynamically Significant Coronary Artery Disease: Patient-Specific Cutoffs in Quantitative Myocardial Blood Flow Using [15O]H2O PET Imaging
    Hoek, Roel
    van Diemen, Pepijn A.
    Raijmakers, Pieter G.
    Driessen, Roel S.
    Somsen, Yvemarie B. O.
    de Winter, Ruben W.
    Jukema, Ruurt A.
    Twisk, Jos W. R.
    Robbers, Lourens F. H. J.
    van der Harst, Pim
    Saraste, Antti
    Lubberink, Mark
    Sorensen, Jens
    Knaapen, Paul
    Knuuti, Juhani
    Danad, Ibrahim
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65 (07) : 1113 - 1121
  • [40] Long-term prognostic value of [15O]H2O PET imaging in patients suspected for cerebral hemodynamic insufficiency
    Bach, Mathias Jacobsen
    Jakubauskaite, Audrone
    Law, Ian
    Henriksen, Otto Molby
    Havsteen, Inger
    Henriksen, Alexander Cuculiza
    Rosenbaum, Sverre
    Marner, Lisbeth
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2024, 33 (01):