Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: comparison with the results of [15O]H2O PET

被引:0
|
作者
Yoshinori Ito
Chietsugu Katoh
Kazuyuki Noriyasu
Yuji Kuge
Hideto Furuyama
Koichi Morita
Tetsuro Kohya
Akira Kitabatake
Nagara Tamaki
机构
[1] Department of Cardiology,
[2] Hokkaido University Graduate School of Medicine,undefined
[3] Sapporo,undefined
[4] Japan,undefined
[5] Department of Tracer Kinetics,undefined
[6] Hokkaido University Graduate School of Medicine,undefined
[7] Sapporo,undefined
[8] Japan,undefined
[9] Department of Nuclear Medicine,undefined
[10] Hokkaido University Graduate School of Medicine,undefined
[11] N-15,undefined
[12] W-7,undefined
[13] Kita-ku,undefined
[14] Sapporo,undefined
[15] 060-8638 Japan,undefined
关键词
Radionuclide imaging Emission tomography Myocardial blood flow 99mTc-sestamibi Coronary artery disease;
D O I
暂无
中图分类号
学科分类号
摘要
We developed a noninvasive method to quantitatively estimate the myocardial blood flow (MBF) index and flow reserve (MFR) using dynamic and static data obtained with technetium-99m sestamibi, and compared the results with MBF and MFR measured by oxygen-15-labeled water ([15O]H2O) PET. Twenty patients with coronary artery disease (CAD) and nine normal subjects underwent both 99mTc-sestamibi and PET studies within 2 weeks. From the anterior view, dynamic data were acquired for 2 min immediately after the injection of 99mTc-sestamibi, and planar static images were also obtained after 5 min at rest and during ATP stress (0.16 mg kg–1 min–1 for 5 min) on another day. The area under the time-activity curve on the aortic arch (Aorta ACU), myocardial weight with the SPET image (M), and the myocardial count on the planar image for 1 min (Cm) were obtained. The MBF index (MBFI) was calculated as follows: MBFI=<I>C</I><SUB>m</SUB>/Aorta ACU×100/<I>M</I>. MFR was measured by dividing the MBFI at ATP stress by MBFI at rest. The MBFI measured by 99mTc-sestamibi was significantly correlated with MBF obtained using [15O]H2O PET (MBFI=13.174+11.732×MBF, r=0.821, P<0.001). Furthermore, MFR measured by 99mTc-sestamibi was well correlated with that obtained using [15O]H2O PET, with some underestimation (r=0.845, P<0.001). MFR using 99mTc-sestamibi in patients with CAD was significantly lower than that in normal subjects (CAD: 1.484±0.256 vs normal: 2.127±0.308, P<0.001). These data suggest that the MBFI and MFR can be measured with 99mTc-sestamibi. This may be useful for the quantitative assessment of CAD, especially in those patients with diffuse coronary disease.
引用
收藏
页码:281 / 287
页数:6
相关论文
共 50 条
  • [1] Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging:: comparison with the results of [15O]H2O PET
    Ito, Y
    Katoh, C
    Noriyasu, K
    Kuge, Y
    Furuyama, H
    Morita, K
    Kohya, T
    Kitabatake, A
    Tamaki, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (02) : 281 - 287
  • [2] IMPACT OF REVASCULARIZATION ON ABSOLUTE MYOCARDIAL BLOOD FLOW AS ASSESSED BY SERIAL [15O]H2O PET IMAGING: A COMPARISON WITH FRACTIONAL FLOW RESERVE
    Driessen, Roel
    Danad, Ibrahim
    Stuijfzand, Wijnand
    Schumacher, Stefan
    Knuuti, Juhani
    Lammertsma, Adriaan
    van Rossum, Albert
    Van Royen, Niels
    Raijmakers, Pieter
    Knaapen, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1480 - 1480
  • [3] Impact of Revascularization on Fractional Flow Reserve and Absolute Myocardial Blood Flow as Assessed by Serial [15O]H2O PET Imaging
    Driessen, Roel
    Danad, Ibrahim
    Stuijfzand, Wijnand
    Schumacher, Stefan
    Lammertsma, Adriaan
    van Rossum, Albert
    van Royen, Niels
    Raijmakers, Pieter
    Knaapen, Paul
    CIRCULATION, 2017, 136
  • [4] Impact of Revascularization on Absolute Myocardial Blood Flow as Assessed by Serial [15O]H2O Positron Emission Tomography Imaging: A Comparison With Fractional Flow Reserve
    Driessen, Roel S.
    Danad, Ibrahim
    Stuijfzand, Wijnand J.
    Schumacher, Stefan P.
    Knuuti, Juhani
    Maki, Maija
    Lammertsma, Adriaan A.
    van Rossum, Albert C.
    van Royen, Niels
    Raijmakers, Pieter G.
    Knaapen, Paul
    CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (05) : e007417
  • [5] Parametric renal blood flow imaging using [15O]H2O and PET
    Nobuyuki Kudomi
    Niina Koivuviita
    Kaisa E. Liukko
    Vesa J. Oikonen
    Tuula Tolvanen
    Hidehiro Iida
    Risto Tertti
    Kaj Metsärinne
    Patricia Iozzo
    Pirjo Nuutila
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 683 - 691
  • [6] Parametric renal blood flow imaging using [15O]H2O and PET
    Kudomi, Nobuyuki
    Koivuviita, Niina
    Liukko, Kaisa E.
    Oikonen, Vesa J.
    Tolvanen, Tuula
    Iida, Hidehiro
    Tertti, Risto
    Metsarinne, Kaj
    Iozzo, Patricia
    Nuutila, Pirjo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (04) : 683 - 691
  • [7] The Evaluation of Caffeine Effects in Myocardial Blood Flow, Myocardial Flow Reserve and Hemodynamic Change by 99mTc-sestamibi Dynamic SPECT/CT
    Chan, Hung-Pin
    Hu, Chin
    Peng, Nan-Jing
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [8] Absolute quantification of regional myocardial blood flow using 15O H2O PET with and without attenuation correction
    Ishida, Masaki
    Ichikawa, Yasutaka
    Tomita, Yoya
    Kamigiri, Akira
    Sakuma, Hajime
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [9] Clinical impact of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi CZT SPECT as improving diagnostic accuracy in CAD patients
    Chiu, Chuang-Hsin
    Chen, I-Feng
    Lin, Li-Fan
    Chen, Ing-jou
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [10] Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease
    Bailing Hsu
    Fu-Chung Chen
    Tao-Cheng Wu
    Wen-Sheng Huang
    Po-Nien Hou
    Chien-Cheng Chen
    Guang-Uei Hung
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 2294 - 2306