Failure Analysis of Once-Through Steam Generator (OTSG) Tube

被引:1
|
作者
Tina, Wahida [1 ]
Donaldson, Elizabeth [1 ]
Dickinson, Thomas E. [2 ]
Schmidt, William Hal [3 ]
机构
[1] Department of Asset Management, Lansing Board of Water and Light, 830 E. Hazel, Lansing,MI,48912, United States
[2] REO Town Plant, Peffley Chiller Plant, Lansing Board of Water and Light, 1201 S Washington Ave, Lansing,MI,48910, United States
[3] Department of Project Engineering, Lansing Board of Water and Light, 1201 S Washington Ave, Lansing,MI,48910, United States
来源
关键词
Descaling - Energy dispersive X ray analysis - Failure (mechanical) - Flow of gases - Heat exchangers - Heat transfer - Heat treatment - Nickel compounds - Optical emission spectroscopy - Scanning electron microscopy - Steam - Steam generators - Stress corrosion cracking - Thermoelectric power plants - Tubing - X ray diffraction analysis;
D O I
10.1115/1.4062769
中图分类号
学科分类号
摘要
The once-through steam generator (OTSG) produces superheated steam using purified feed water. The plant-specific water quality, steam quality, high temperature, and pressure operations lead to the leakage of the OTSG tubes with economic, safety, and environmental consequences. Tube leakage is one of the most frequent causes of OTSG tube failure. A leaking tube was discovered within the OTSG unit of the 110 MW cogeneration plant. The failed section of the tube was removed from the steam generator. Several metallurgical examinations of this tube segment were performed to identify the failure mode and cause. A portion of the tube was analyzed using optical emission spectroscopy (OES) to determine the alloy composition. The results confirmed that the tubing was fabricated from a material consistent with chemical specifications for ASME Specification SB 407 Inconel Alloy 800 (UNS N08800). Glass bead blasting was used to determine the deposit-weight-density (DWD). The DWD value was a maximum of 5.1 g/ft2. The maximum internal deposit thickness was 0.002 in. No evidence of overheating was observed. Scanning electron microscopeenergy-dispersive x-ray analysis (SEM-EDXA) was used to determine the elemental composition of the internal deposits. The results indicated that the internal gray deposits primarily comprised iron, chromium, and nickel compounds. There were also fewer amounts of sodium, silicon, aluminum, potassium, and calcium species. The subject tube failure involved a through-wall crack that occurred as stress corrosion cracking (SCC). Additions of caustic solution used in OTSG water treatment practices potentially induced corrosive substances into the tube. Copyright © 2023 by ASME.
引用
收藏
相关论文
共 50 条
  • [21] Simulation analysis of static and dynamic characteristics of once-through steam generator in concentric annuli tube
    Wei Zhang
    Xin-qian Bian
    Guo-qing Xia
    Journal of Marine Science and Application, 2006, 5 (3) : 36 - 40
  • [23] Thermal-hydraulic analysis of once-through steam generator with annular narrow slot tube
    Han, Jinyu
    He, Wen
    Liu, Yao
    Zhao, Chenru
    Bo, Hanliang
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [24] Development of a computer code for thermalehydraulic design and analysis of helically coiled tube once-through steam generator
    Zhang, Yaoli
    Wang, Duo
    Lin, Jianshu
    Hao, Junwei
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (07) : 1388 - 1395
  • [25] Thermal-Hydraulic Performance Analysis and Tube Inlet Orifice Design of a Once-Through Steam Generator
    Han, Hun Sik
    Kim, Young In
    Bae, Youngmin
    Kim, Sang Ji
    HEAT TRANSFER ENGINEERING, 2021, 43 (3-5) : 198 - 207
  • [26] A MOVABLE BOUNDARY MODEL FOR ONCE-THROUGH STEAM-GENERATOR ANALYSIS
    TZANOS, CP
    NUCLEAR TECHNOLOGY, 1988, 82 (01) : 5 - 17
  • [27] Multi-Objective Optimization of Double-Tube Once-Through Steam Generator
    Wei, Xinyu
    Dai, Chunhui
    Tai, Yun
    Zhao, Fuyu
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2012, 134 (07):
  • [28] Two-phase flow instabilities in helical tube of once-through steam generator
    Shi, Shaoping
    Zhou, Fangde
    Hedongli Gongcheng/Nuclear Power Engineering, 1997, 18 (05): : 419 - 425
  • [29] Dynamic characteristics analysis of a once-through heat recovery steam generator
    Du, Wenjing
    Li Jinbo
    Yuan Baoqiang
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [30] Three-Dimensional CFD Model Development and Validation for Once-Through Steam Generator (OTSG): Coupling Combustion, Heat Transfer and Steam Generation
    Mahvelati, Ehsan Askari
    Forcinito, Mario
    Fitschy, Laurent
    Maesen, Arthur
    CHEMENGINEERING, 2022, 6 (02)