THE ANALYSIS OF THE FLOW OF BLOOD IN A STENOSED ARTERY THROUGH SIMULATION: A COMPARISON AMONG VARIOUS NON-NEWTONIAN MODELS

被引:2
|
作者
Narayan, S. shankar [1 ]
Bhattacharjee, Anuradha [2 ]
Saha, Sunanda [3 ]
Puneeth, Venkatesh [4 ]
Singhal, Abhinav [4 ]
Abdullaeva, Barno Sayfutdinovna [5 ,6 ]
机构
[1] Ramaiah Univ Appl Sci, Dept Math & Stat, Bengaluru 560058, India
[2] Dayananda Sagar Univ, Dept Math, Bengaluru 560068, India
[3] Vellore Inst Technol, Dept Math, Vellore 632014, India
[4] CHRIST Deemed Univ, Dept Computat Sci, Ghaziabad 201003, India
[5] Tashkent State Pedag Univ, Pedag Sci, Tashkent, Uzbekistan
[6] Tashkent State Pedag Univ, Sci Affairs, Tashkent, Uzbekistan
关键词
Coronary artery; atherosclerosis; low-density lipoprotein; stenosis; rheology; RIGHT CORONARY-ARTERIES; MAGNETIC-FIELD; NANOPARTICLES; NANOFLUID; GOLD;
D O I
10.1142/S0219519424500106
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper focuses on the dual quality of blood, Newtonian and non-Newtonian, in particular by exploring the energy curves. Careful investigation of the dual property of blood has been made by considering two different geometries to represent a stenosed arterial segment. We present a cautious assessment of non-Newtonian blood rheology impacts in arterial stream simulations by coupling the Newtonian and non-Newtonian models. The flow of energy through the two flow dimensions is meticulously investigated using velocity (kinetic energy), pressure, and wall shear stress (pressure energy). Besides, the proper implementation of an interface boundary condition (IBC) was emphasized to ensure consistency with the flow conditions downstream of a backward-facing step. The integration of the Newtonian and non-Newtonian models adjoins the novelty of the current research. The energy curves are obtained by implementing five different non-Newtonian models to designate a suitable non-Newtonian model for blood flow investigations. The combination of the non-Newtonian models enforced in this research is novel and particular attention is paid to the energy curves obtained. The conclusion was to elect the Carreau model as a suitable non-Newtonian rheological model for the blood flow study. This study was able to finalize the fact that the coupling of Newtonian and non-Newtonian models is necessary to obtain accurate results. For the sinusoidal waveform considered for the velocity, Carreau and the Power law models yield better results, eliminating the other non-Newtonian models from the list. With a better inlet condition imposed in the form of the Fourier series for pressure and velocity, the Carreau model yields the best results.
引用
收藏
页数:33
相关论文
共 50 条
  • [41] Non-Newtonian biomagnetic fluid flow through a stenosed bifurcated artery with a slip boundary condition
    Yaxin Xu
    Jing Zhu
    Liancun Zheng
    Xinhui Si
    Applied Mathematics and Mechanics, 2020, 41 : 1611 - 1630
  • [42] Effect of non-Newtonian behaviour on fluid structural interaction for flow through a model stenosed artery
    Haque, Md Rejaul
    Hossain, Md Emran
    Hasan, A. B. M. Toufique
    10TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2013), 2014, 90 : 358 - 363
  • [43] Computational Modeling of Non-Newtonian Blood Flow Through Stenosed Arteries in the Presence of Magnetic Field
    Alshare, Aiman
    Tashtoush, Bourhan
    El-Khalil, Hossam H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (11):
  • [44] Numerical Study of the Significance of the Non-Newtonian Nature of Blood in Steady Flow Through a Stenosed Vessel
    Bodnar, Tomas
    Sequeira, Adelia
    ADVANCES IN MATHEMATICAL FLUID MECHANICS: DEDICATED TO GIOVANNI PAOLO GALDI ON THE OCCASION OF HIS 60TH BIRTHDAY, INTERNATIONAL CONFERENCE ON MATHEMATICAL FLUID MECHANICS, 2007, 2010, : 83 - +
  • [45] ANALYSIS OF ONE-DIMENSIONAL NON-NEWTONIAN MODELS FOR SIMULATION OF BLOOD FLOW IN ARTERIES
    Krivovichev, Gerasim V. V.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (07)
  • [46] FLOW INVESTIGATION ON ARTERY MODELS WITH NEWTONIAN AND NON-NEWTONIAN FLUIDS
    LIEPSCH, D
    MORAVEC, S
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (08) : 584 - 585
  • [47] Computational Analysis of Transient non-Newtonian Blood Flow in Magnetic Targeting Drug Delivery in Stenosed Carotid Bifurcation Artery
    Alimohamadi, Haleh
    Imani, Mohsen
    Forouzandeh, Behjat
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2015, 42 (02) : 149 - 169
  • [48] Concentric ballooned catheterization to the fractional non-newtonian hybrid nano blood flow through a stenosed aneurysmal artery with heat transfer
    Obaid Ullah Mehmood
    Sehrish Bibi
    Dzuliana F. Jamil
    Salah Uddin
    Rozaini Roslan
    Mohd Kamalrulzaman Md Akhir
    Scientific Reports, 11
  • [49] Magnetic Nanoparticles for Drug Delivery through Tapered Stenosed Artery with Blood Based Non-Newtonian Fluid
    Bhatti, Muhammad Mubashir
    Sait, Sadiq M.
    Ellahi, Rahmat
    PHARMACEUTICALS, 2022, 15 (11)
  • [50] On the steady flow of non-newtonian fluid through multi-stenosed elliptical artery: A theoretical model
    Shahzad, Muhammad Hasnain
    Nadeem, Sohail
    Awan, Aziz Ullah
    Allahyani, Seham Ayesh
    Ahammad, N. Ameer
    Eldin, Sayed M.
    AIN SHAMS ENGINEERING JOURNAL, 2024, 15 (01)