THE ANALYSIS OF THE FLOW OF BLOOD IN A STENOSED ARTERY THROUGH SIMULATION: A COMPARISON AMONG VARIOUS NON-NEWTONIAN MODELS

被引:2
|
作者
Narayan, S. shankar [1 ]
Bhattacharjee, Anuradha [2 ]
Saha, Sunanda [3 ]
Puneeth, Venkatesh [4 ]
Singhal, Abhinav [4 ]
Abdullaeva, Barno Sayfutdinovna [5 ,6 ]
机构
[1] Ramaiah Univ Appl Sci, Dept Math & Stat, Bengaluru 560058, India
[2] Dayananda Sagar Univ, Dept Math, Bengaluru 560068, India
[3] Vellore Inst Technol, Dept Math, Vellore 632014, India
[4] CHRIST Deemed Univ, Dept Computat Sci, Ghaziabad 201003, India
[5] Tashkent State Pedag Univ, Pedag Sci, Tashkent, Uzbekistan
[6] Tashkent State Pedag Univ, Sci Affairs, Tashkent, Uzbekistan
关键词
Coronary artery; atherosclerosis; low-density lipoprotein; stenosis; rheology; RIGHT CORONARY-ARTERIES; MAGNETIC-FIELD; NANOPARTICLES; NANOFLUID; GOLD;
D O I
10.1142/S0219519424500106
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper focuses on the dual quality of blood, Newtonian and non-Newtonian, in particular by exploring the energy curves. Careful investigation of the dual property of blood has been made by considering two different geometries to represent a stenosed arterial segment. We present a cautious assessment of non-Newtonian blood rheology impacts in arterial stream simulations by coupling the Newtonian and non-Newtonian models. The flow of energy through the two flow dimensions is meticulously investigated using velocity (kinetic energy), pressure, and wall shear stress (pressure energy). Besides, the proper implementation of an interface boundary condition (IBC) was emphasized to ensure consistency with the flow conditions downstream of a backward-facing step. The integration of the Newtonian and non-Newtonian models adjoins the novelty of the current research. The energy curves are obtained by implementing five different non-Newtonian models to designate a suitable non-Newtonian model for blood flow investigations. The combination of the non-Newtonian models enforced in this research is novel and particular attention is paid to the energy curves obtained. The conclusion was to elect the Carreau model as a suitable non-Newtonian rheological model for the blood flow study. This study was able to finalize the fact that the coupling of Newtonian and non-Newtonian models is necessary to obtain accurate results. For the sinusoidal waveform considered for the velocity, Carreau and the Power law models yield better results, eliminating the other non-Newtonian models from the list. With a better inlet condition imposed in the form of the Fourier series for pressure and velocity, the Carreau model yields the best results.
引用
收藏
页数:33
相关论文
共 50 条
  • [21] Finite element analysis of non-Newtonian magnetohemodynamic flow conveying nanoparticles through a stenosed coronary artery
    Vasu, B.
    Dubey, Ankita
    Beg, O. Anwar
    HEAT TRANSFER-ASIAN RESEARCH, 2020, 49 (01): : 33 - 66
  • [22] FDM analysis for MHD flow of a non-Newtonian fluid for blood flow in stenosed arteries
    D. S. Sankar
    Usik Lee
    Journal of Mechanical Science and Technology, 2011, 25 : 2573 - 2581
  • [23] FDM analysis for MHD flow of a non-Newtonian fluid for blood flow in stenosed arteries
    Sankar, D. S.
    Lee, Usik
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2011, 25 (10) : 2573 - 2581
  • [24] Unsteady non-Newtonian blood flow through a tapered overlapping stenosed catheterized vessel
    Ali, N.
    Zaman, A.
    Sajid, M.
    Nieto, J. J.
    Torres, A.
    MATHEMATICAL BIOSCIENCES, 2015, 269 : 94 - 103
  • [25] Role of slip velocity in blood flow through stenosed arteries: A non-Newtonian model
    Misra, J. C.
    Shit, G. C.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2007, 7 (03) : 337 - 353
  • [26] Numerical investigation of unsteady pulsatile Newtonian/non-Newtonian blood flow through curved stenosed arteries
    Lakzian, E.
    Akbarzadeh, P.
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 30 (5-6) : 525 - 540
  • [27] Comparison of Newtonian and Non-newtonian Fluid Models in Blood Flow Simulation in Patients With Intracranial Arterial Stenosis
    Liu, Haipeng
    Lan, Linfang
    Abrigo, Jill
    Ip, Hing Lung
    Soo, Yannie
    Zheng, Dingchang
    Wong, Ka Sing
    Wang, Defeng
    Shi, Lin
    Leung, Thomas W.
    Leng, Xinyi
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [28] On the non-Newtonian blood flow in the elliptical multi-stenosed inclined artery: Analytical approach
    Allahyani, Seham Ayesh
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2024, 38 (03):
  • [29] Computational simulation of non-Newtonian blood flow in carotid bifurcation for investigating the various rheological blood models
    Jahanyfard, E.
    Firoozabadi, B.
    Chegini, A. Goodarzvand
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 2: BIOMEDICAL AND BIOTECHNOLOGY ENGINEERING, 2008, : 263 - 270
  • [30] Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis
    Tian, Fang-Bao
    Zhu, Luoding
    Fok, Pak-Wing
    Lu, Xi-Yun
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (09) : 1098 - 1113