THE ANALYSIS OF THE FLOW OF BLOOD IN A STENOSED ARTERY THROUGH SIMULATION: A COMPARISON AMONG VARIOUS NON-NEWTONIAN MODELS

被引:2
|
作者
Narayan, S. shankar [1 ]
Bhattacharjee, Anuradha [2 ]
Saha, Sunanda [3 ]
Puneeth, Venkatesh [4 ]
Singhal, Abhinav [4 ]
Abdullaeva, Barno Sayfutdinovna [5 ,6 ]
机构
[1] Ramaiah Univ Appl Sci, Dept Math & Stat, Bengaluru 560058, India
[2] Dayananda Sagar Univ, Dept Math, Bengaluru 560068, India
[3] Vellore Inst Technol, Dept Math, Vellore 632014, India
[4] CHRIST Deemed Univ, Dept Computat Sci, Ghaziabad 201003, India
[5] Tashkent State Pedag Univ, Pedag Sci, Tashkent, Uzbekistan
[6] Tashkent State Pedag Univ, Sci Affairs, Tashkent, Uzbekistan
关键词
Coronary artery; atherosclerosis; low-density lipoprotein; stenosis; rheology; RIGHT CORONARY-ARTERIES; MAGNETIC-FIELD; NANOPARTICLES; NANOFLUID; GOLD;
D O I
10.1142/S0219519424500106
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper focuses on the dual quality of blood, Newtonian and non-Newtonian, in particular by exploring the energy curves. Careful investigation of the dual property of blood has been made by considering two different geometries to represent a stenosed arterial segment. We present a cautious assessment of non-Newtonian blood rheology impacts in arterial stream simulations by coupling the Newtonian and non-Newtonian models. The flow of energy through the two flow dimensions is meticulously investigated using velocity (kinetic energy), pressure, and wall shear stress (pressure energy). Besides, the proper implementation of an interface boundary condition (IBC) was emphasized to ensure consistency with the flow conditions downstream of a backward-facing step. The integration of the Newtonian and non-Newtonian models adjoins the novelty of the current research. The energy curves are obtained by implementing five different non-Newtonian models to designate a suitable non-Newtonian model for blood flow investigations. The combination of the non-Newtonian models enforced in this research is novel and particular attention is paid to the energy curves obtained. The conclusion was to elect the Carreau model as a suitable non-Newtonian rheological model for the blood flow study. This study was able to finalize the fact that the coupling of Newtonian and non-Newtonian models is necessary to obtain accurate results. For the sinusoidal waveform considered for the velocity, Carreau and the Power law models yield better results, eliminating the other non-Newtonian models from the list. With a better inlet condition imposed in the form of the Fourier series for pressure and velocity, the Carreau model yields the best results.
引用
收藏
页数:33
相关论文
共 50 条
  • [1] PHYSIOLOGICAL NON-NEWTONIAN BLOOD FLOW THROUGH SINGLE STENOSED ARTERY
    Mamun, Khairuzzaman
    Ali, Mohammad
    Akhter, Most. Nasrin
    THEORETICAL AND APPLIED MECHANICS, 2016, 43 (01) : 99 - 115
  • [2] Physiological Non-Newtonian Blood Flow through Single Stenosed Artery
    Mamun, Khairuzzaman
    Rahman, Mohammad Matiur
    Akhter, Most. Nasrin
    Ali, Mohammad
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2015), 2016, 1754
  • [3] Comparative Study of Newtonian and Non-Newtonian Blood Flow through a Stenosed Carotid Artery
    Rahman, Mohammad Matiur
    Hossain, Md. Anwar
    Mamun, Khairuzzaman
    Akhter, Most. Nasrin
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2017), 2018, 1980
  • [4] Modeling of unsteady non-Newtonian blood flow through a stenosed artery: with nanoparticles
    Zaman, A.
    Khan, Ambreen Afsar
    Ali, N.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (06)
  • [5] Modeling of unsteady non-Newtonian blood flow through a stenosed artery: with nanoparticles
    A. Zaman
    Ambreen Afsar Khan
    N. Ali
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2018, 40
  • [6] Analysis of non-newtonian fluid flow in a stenosed artery
    Sapna, S.
    INTERNATIONAL JOURNAL OF PHYSICAL SCIENCES, 2009, 4 (11): : 663 - 671
  • [7] Study of Non-Newtonian Models for 1D Blood Flow Through a Stenosed Carotid Artery
    Udupa, Mahesh
    Saha, Sunanda
    MATHEMATICS AND COMPUTING, ICMC 2022, 2022, 415 : 523 - 539
  • [8] Non-Newtonian Flow of Blood in a Catheterized Bifurcated Stenosed Artery
    Misra, Jagadis Chandra
    Shit, Gopal Chandra
    Pramanik, Ranjan
    JOURNAL OF BIONIC ENGINEERING, 2018, 15 (01) : 173 - 184
  • [9] Non-Newtonian flow of blood in a catheterized bifurcated stenosed artery
    Jagadis Chandra Misra
    Gopal Chandra Shit
    Ranjan Pramanik
    Journal of Bionic Engineering, 2018, 15 : 173 - 184
  • [10] Unsteady response of non-Newtonian blood flow through a stenosed artery in magnetic field
    Ikbal, Md. A.
    Chakravarty, S.
    Wong, Kelvin K. L.
    Mazumdar, J.
    Mandal, P. K.
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2009, 230 (01) : 243 - 259