A new surface plasmon resonance-based immunoassay for rapid and sensitive quantification of D-dimer in human plasma for thrombus screening

被引:0
|
作者
Hu, Xin 'er [1 ]
Lv, Diya [2 ]
Qi, Minyu [3 ]
Zhang, Ying [3 ]
Wang, Xiaofei [3 ]
Gu, Jiayu [3 ,4 ]
Wang, Dongyao [5 ]
Chen, Xiaofei [2 ]
Liu, Yue [5 ]
Cao, Yan [3 ]
Zhang, Hai [1 ]
机构
[1] Tongji Univ, Shanghai Matern & Infant Hosp 1, Shanghai Inst Maternal Fetal Med & Gynecol Oncol, Sch Med,Shanghai Key Lab Maternal Fetal Med,Dept P, Shanghai 200092, Peoples R China
[2] Naval Med Univ, Ctr Instrumental Anal, Sch Pharm, Shanghai 200433, Peoples R China
[3] Naval Med Univ, Sch Pharm, Dept Biochem Pharm, Shanghai 200433, Peoples R China
[4] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
[5] Naval Med Univ, Sch Pharm, Dept Pharmaceut Anal, Shanghai 200433, Peoples R China
关键词
surface plasmon resonance (SPR); D-dimer; Plasma; Latex -enhanced immunoturbidimetric; immunoassay; Quantification; AXSYM D-DIMER; ASSAY; VALIDATION; DIAGNOSIS;
D O I
10.1016/j.jchromb.2024.124102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
D-dimer is a protein fragment generated during the fibrin breakdown by plasmin, and it serves as a mature biomarker for diagnosing thrombotic disorders. A novel immunoassay method based on surface plasmon resonance (SPR) has been developed, validated, and successfully applied for the quantification of D-dimer in human plasma with high sensitivity and rapidity. In this methodological study, we investigated the activity and stability of the SPR biosensor, sample pre-processing, washing conditions, intra-day and inter -day precision and accuracy and detection parameters, including a limit of detection of 8.3 ng/mL, a detection range spanning from 31.25 to 4000 ng/mL, and a detection time of 20 min. We compared D-dimer plasma concentration determination results using SPR with a classical latex -enhanced immunoturbidimetric immunoassay in 29 healthy individuals and thrombotic patients, and both methods exhibited consistency. Furthermore, we propose a hypothesis about the relationship between the concentration of D-dimer and its molecular weight. With an increase in the D-dimer concentration in plasma, the D-dimer approaches its simplest form (190 kDa).
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A New Surface Plasmon Resonance-Based Immunoassay for Rapid, Reproducible and Sensitive Quantification of Pentraxin-3 in Human Plasma
    Canovi, Mara
    Lucchetti, Jacopo
    Stravalaci, Matteo
    Valentino, Sonia
    Bottazzi, Barbara
    Salmona, Mario
    Bastone, Antonio
    Gobbi, Marco
    SENSORS, 2014, 14 (06): : 10864 - 10875
  • [2] PROPERTIES OF A RAPID IMMUNOASSAY FOR D-DIMER IN HUMAN PLASMA
    DALE, S
    BROSSTAD, F
    HOLTLUND, J
    BRANDSNES, O
    GARTNER, E
    MORK, E
    GOGSTAD, G
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1270 - 1270
  • [3] Surface plasmon resonance-based immunoassay for human fetuin A
    Vashist, S. K.
    Schneider, E. M.
    Luong, J. H. T.
    ANALYST, 2014, 139 (09) : 2237 - 2242
  • [4] Surface plasmon resonance-based immunoassay for procalcitonin
    Vashist, Sandeep Kumar
    Schneider, E. Marion
    Barth, Eberhard
    Luong, John H. T.
    ANALYTICA CHIMICA ACTA, 2016, 938 : 129 - 136
  • [5] Development of surface plasmon resonance-based immunoassay for cephalexin
    Dillon, P
    Daly, S
    Browne, J
    Manning, B
    O'Kennedy, R
    van Amerongen, A
    OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 911 - 922
  • [6] Surface plasmon resonance-based immunoassay for human C-reactive protein
    Vashist, S. K.
    Schneider, E. M.
    Luong, J. H. T.
    ANALYST, 2015, 140 (13) : 4445 - 4452
  • [7] Graphene Oxide-Assisted Surface Plasmon Resonance Biosensor for Simple and Rapid Determination of D-Dimer in Plasma
    Wang, Jiaying
    Lu, Yi
    Zhang, Yulin
    Ning, Yong
    Zhang, Guo-Jun
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (07) : 6878 - 6883
  • [8] Quantification of Somatostatin with a Surface Plasmon Resonance-based Biosensor
    Gao Jin-Hang
    Liu Rui
    Tong Huan
    Li Xian
    Qang Ou
    Tang Cheng-Wei
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2010, 31 (07): : 1327 - 1331
  • [9] CONTINUOUS IMMUNOASSAY FOR SULFAMETHAZINE BY SURFACE PLASMON RESONANCE-BASED BIOSENSOR
    Li, Hui
    Cai, Hao-Yuan
    Chen, Xing
    Sun, Jian-Hai
    Zhang, Lu-Lu
    Cui, Da-Fu
    ANALYTICAL LETTERS, 2010, 43 (03) : 499 - 507
  • [10] Development of Surface Plasmon Resonance-Based Biosensor Immunoassay for Sulfamethoxazole
    Hui Li Dafu Cui Yujie Wang Haoyuan Cai Junbo Wang Zipan Zheng State Key Labof Transducer TechInstof ElectronicsChinese Academy of SciencesBeijing China
    稀有金属材料与工程, 2006, (S3) : 91 - 94