A new surface plasmon resonance-based immunoassay for rapid and sensitive quantification of D-dimer in human plasma for thrombus screening

被引:0
|
作者
Hu, Xin 'er [1 ]
Lv, Diya [2 ]
Qi, Minyu [3 ]
Zhang, Ying [3 ]
Wang, Xiaofei [3 ]
Gu, Jiayu [3 ,4 ]
Wang, Dongyao [5 ]
Chen, Xiaofei [2 ]
Liu, Yue [5 ]
Cao, Yan [3 ]
Zhang, Hai [1 ]
机构
[1] Tongji Univ, Shanghai Matern & Infant Hosp 1, Shanghai Inst Maternal Fetal Med & Gynecol Oncol, Sch Med,Shanghai Key Lab Maternal Fetal Med,Dept P, Shanghai 200092, Peoples R China
[2] Naval Med Univ, Ctr Instrumental Anal, Sch Pharm, Shanghai 200433, Peoples R China
[3] Naval Med Univ, Sch Pharm, Dept Biochem Pharm, Shanghai 200433, Peoples R China
[4] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
[5] Naval Med Univ, Sch Pharm, Dept Pharmaceut Anal, Shanghai 200433, Peoples R China
关键词
surface plasmon resonance (SPR); D-dimer; Plasma; Latex -enhanced immunoturbidimetric; immunoassay; Quantification; AXSYM D-DIMER; ASSAY; VALIDATION; DIAGNOSIS;
D O I
10.1016/j.jchromb.2024.124102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
D-dimer is a protein fragment generated during the fibrin breakdown by plasmin, and it serves as a mature biomarker for diagnosing thrombotic disorders. A novel immunoassay method based on surface plasmon resonance (SPR) has been developed, validated, and successfully applied for the quantification of D-dimer in human plasma with high sensitivity and rapidity. In this methodological study, we investigated the activity and stability of the SPR biosensor, sample pre-processing, washing conditions, intra-day and inter -day precision and accuracy and detection parameters, including a limit of detection of 8.3 ng/mL, a detection range spanning from 31.25 to 4000 ng/mL, and a detection time of 20 min. We compared D-dimer plasma concentration determination results using SPR with a classical latex -enhanced immunoturbidimetric immunoassay in 29 healthy individuals and thrombotic patients, and both methods exhibited consistency. Furthermore, we propose a hypothesis about the relationship between the concentration of D-dimer and its molecular weight. With an increase in the D-dimer concentration in plasma, the D-dimer approaches its simplest form (190 kDa).
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Localized Surface Plasmon Resonance-Based Nanosensor for Rapid Detection of Glyphosate in Food Samples
    Coco, Ariany Soares
    Campos, Fabiana Vasconcelos
    Diaz, Camilo Arturo Rodriguez
    Guimaraes, Marco Cesar Cunegundes
    Prado, Adilson Ribeiro
    de Oliveira, Jairo Pinto
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [42] Measurement of plasma D-Dimer by a new rapid Biopool Miniquant assay.
    Haroon, ZA
    Rathinam, C
    Greenberg, CS
    BLOOD, 2000, 96 (11) : 74B - 74B
  • [43] A surface plasmon resonance-based assay for small molecule inhibitors of human cyclophilin A
    Wear, MA
    Patterson, A
    Malone, K
    Dunsmore, C
    Turner, NJ
    Walkinshaw, MD
    ANALYTICAL BIOCHEMISTRY, 2005, 345 (02) : 214 - 226
  • [44] A Surface Plasmon Resonance-Based Immunoassay to Investigate the Structural Diversity of Brain-Extracted PrP Molecules
    Tapella, Laura
    Stravalaci, Matteo
    Biasini, Emiliano
    Bastone, Antonio
    Gobbi, Marco
    Chiesa, Roberto
    PRION, 2011, 5 : 89 - 89
  • [45] Quantification of Immunoglobulin G in Bovine and Caprine Milk Using a Surface Plasmon Resonance-Based Immunosensor
    Crosson, Cyril
    Thomas, Daniel
    Rossi, Claire
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (06) : 3259 - 3264
  • [46] NEW HIGH SENSITIVE LOCI D-DIMER METHOD FOR THE DETECTION OF VERY LOW CONCENTRATIONS IN HUMAN CITRATED PLASMA*
    Ehm, M.
    Kraul, D.
    Kuhn, U.
    Pohlack-Marsch, O.
    Vesper, P.
    Gross, U.
    Schelp, C.
    Oehler-Keil, C.
    THROMBOSIS RESEARCH, 2014, 133 : S76 - S76
  • [47] Highly sensitive surface plasmon resonance-based optical fiber multi-parameter sensor
    Velazquez-Gonzalez, J. S.
    Monzon-Hernandez, D.
    Martinez-Pinon, F.
    Hernandez-Romano, I.
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 1249 - 1252
  • [48] Design and construction of a localized surface plasmon resonance-based gold nanobiosensor for rapid detection of brucellosis
    Vakili, Sina
    Asadikaram, Gholamreza
    Torkzadeh-Mahani, Masoud
    Behroozikhah, Alimohammad
    Nematollahi, Mohammad Hadi
    Savardashtaki, Amir
    KUWAIT JOURNAL OF SCIENCE, 2021, 48 (03)
  • [49] Rapid detection of melamine based on immunoassay using portable surface plasmon resonance biosensor
    Wu, Huanan
    Li, Haiyan
    Chua, Frankie Z. H.
    Li, Sam Fong Yau
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 541 - 546
  • [50] Optimization of surface plasmon resonance-based biosensors for monitoring hemoglobin levels in human blood
    A. Keshavarz
    S. Zangenehzadeh
    A. Hatef
    Applied Nanoscience, 2020, 10 : 1465 - 1474