A fully automatic parenchyma extraction method for MRI T2*relaxometry of iron loaded liver in transfusion-dependent patients

被引:0
|
作者
Lian, Zifeng [1 ,2 ,3 ,4 ,5 ,6 ]
Lu, Qiqi [1 ,2 ,3 ,4 ,5 ,6 ]
Lin, Bingquan [7 ]
Chen, Lingjian [8 ]
Gong, Jian [1 ]
Hu, Qiugen [1 ,8 ]
Wang, Huafeng [1 ,8 ]
Feng, Yanqiu [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Guangdong Prov Engn Lab Med Imaging & Diagnost Tec, Guangzhou, Peoples R China
[4] Southern Med Univ, Guangdong Hong Kong Macao Greater Bay Area Ctr Bra, Guangdong Hong Kong Macao Greater Bay Area, Guangzhou, Peoples R China
[5] Southern Med Univ, Key Lab Mental Hlth, Minist Educ, Guangzhou, Peoples R China
[6] Southern Med Univ, Guangdong Hong Kong Joint Lab Psychiat Disorders, Guangzhou, Peoples R China
[7] Southern Med Univ, Nanfang Hosp, Dept Med Imaging Ctr, Guangzhou, Peoples R China
[8] Southern Med Univ, Shunde Hosp, Peoples Hosp Shunde 1, Dept Radiol, Foshan, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; T2*relaxometry; Liver iron loaded; Deep learning; Segmentation; SICKLE-CELL-DISEASE; WHOLE-LIVER; QUANTIFICATION; OVERLOAD; THALASSEMIA; RELAXOMETRY; THERAPY; STORES;
D O I
10.1016/j.mri.2024.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a fully automatic parenchyma extraction method for the T2* relaxometry of iron overload liver. Methods: A retrospective multicenter collection of liver MR examinations from 177 transfusion-dependent patients was conducted. The proposed method extended a semiautomatic parenchyma extraction algorithm to a fully automatic approach by introducing a modified TransUNet on the R2* (1/T2*) map for liver segmentation. Axial liver slices from 129 patients at 1.5 T were allocated to training (85%) and internal test (15%) sets. Two external test sets separately included 1.5 T data from 20 patients and 3.0 T data from 28 patients. The final T2* measurement was obtained by fitting the average signal of the extracted liver parenchyma. The agreement between T2* measurements using fully and semiautomatic parenchyma extraction methods was assessed using coefficient of variation (CoV) and Bland-Altman plots. Results: Dice of the deep network-based liver segmentation was 0.970 +/- 0.019 on the internal dataset, 0.960 +/- 0.035 on the external 1.5 T dataset, and 0.958 +/- 0.014 on the external 3.0 T dataset. The mean difference bias between T2* measurements of the fully and semiautomatic methods were separately 0.12 (95% CI: -0.37, 0.61) ms, 0.04 (95% CI: -1.0, 1.1) ms, and 0.01 (95% CI: -0.25, 0.23) ms on the three test datasets. The CoVs between the two methods were 4.2%, 4.8% and 2.0% on the internal test set and two external test sets. Conclusions: The developed fully automatic parenchyma extraction approach provides an efficient and operatorindependent T2* measurement for assessing hepatic iron content in clinical practice.
引用
收藏
页码:18 / 26
页数:9
相关论文
共 50 条
  • [1] A Novel Semiautomatic Parenchyma Extraction Method for Improved MRI R2*Relaxometry of Iron Loaded Liver
    Feng, Yanqiu
    Feng, Meiyan
    Gao, Huashuai
    Zhang, Xinyuan
    Xin, Xuegang
    Feng, Qianjin
    Chen, Wufan
    He, Taigang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 67 - 78
  • [2] Practical implications of liver and heart iron load assessment by T2*-MRI in children and adults with transfusion-dependent anemias
    Chirnomas, Sarah Deborah
    Geukes-Foppen, Marnix
    Barry, Kristen
    Braunstein, Jennifer
    Kalish, Leslie A.
    Neufeld, Ellis J.
    Powell, Andrew J.
    AMERICAN JOURNAL OF HEMATOLOGY, 2008, 83 (10) : 781 - 783
  • [3] Cardiac iron evaluation by T2*MRI in transfusion dependent patients with acquired anemias
    Angelucci, E.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2007, 92 : 17 - 17
  • [4] Detection of cardiac iron by T2*MRI in transfusion dependent patients with acquired anemias
    Deplano, S.
    Di Tucci, A.
    Pettinau, M.
    Usala, E.
    Angelucci, E.
    LEUKEMIA RESEARCH, 2007, 31 : S103 - S104
  • [5] Assessment By MRI T2*of Iron Accumulation and Removal in Transfusion Dependent MDS Patients
    Merkel, Drorit Grizim
    Avigdor, Abraham
    Nagler, Arnon
    Benjamini, Ohad
    Davidovitz, Yaron
    Goitein, Orly
    BLOOD, 2019, 134
  • [6] Impact Of Liver Iron Overload On Myocardial T2*Response In Transfusion-Dependent Thalassemia Major Patients Treated With Deferasirox For Up To 3 Years
    Porter, John
    Taher, Ali T.
    Aydinok, Yesim
    Cappellini, Maria D.
    Kattamis, Antonis
    El-Ali, Ali
    Martin, Nicolas
    Pennell, Dudley
    BLOOD, 2013, 122 (21)
  • [7] Evaluation of cardial iron deposition by T2 MRI in transfusion dependent patients with myelodysplastic syndromes.
    Deplano, Simona
    Di Tucci, Anna
    Matta, Gildo
    Agus, Annalisa
    Gabbas, Attilio
    Murru, Roberta
    Angelucci, Emanuele
    BLOOD, 2006, 108 (11) : 753A - 753A
  • [8] CORRELATION OF IRON OVERLOAD MARKERS, MRI T2-STAR LIVER/HEART AND BONE MINERAL DENSITOMETRY IN TRANSFUSION-DEPENDENT THALASSEMIA PATIENTS
    Goh, K. G.
    Ahlam, N. K.
    Miza, H. Z.
    Seman, M. R.
    OSTEOPOROSIS INTERNATIONAL, 2019, 30 : S77 - S78
  • [9] Correlation of Transient Elastography With MRI T2* and Serum Ferritin Levels in Children With Transfusion-Dependent Thalassemia
    Nupur Parakh
    Jagdish Chandra
    Indian Pediatrics, 2022, 59 : 929 - 932
  • [10] Correlation of Transient Elastography With MRI T2*and Serum Ferritin Levels in Children With Transfusion-Dependent Thalassemia
    Parakh, Nupur
    Chandra, Jagdish
    INDIAN PEDIATRICS, 2022, 59 (12) : 929 - 932