Determination of the dose rate from the pulse-height spectra of an airborne gamma-ray spectrometer based on an unmanned aerial vehicle

被引:0
|
作者
Gavrilov, S. L. [1 ]
Pimenov, A. E. [1 ]
Shvedov, A. M. [1 ]
Aron, D. V. [1 ]
Dyakov, S. V. [1 ]
机构
[1] RAS, IBRAE, Moscow, Russia
关键词
621.039+51-73;
D O I
10.1007/s10512-024-01084-w
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the present study, data for converting the pulse-height spectra of an airborne gamma-ray spectrometer with a NaI (31 x 31 mm) detector to the dose rate values were obtained using the mathematical simulation. The results were tested using model tasks for determining pulse-height spectra at heights from 15 to 75 m. A point isotropic source of 60Co and the infinite contamination of the soil surface with 137Cs were considered as sources of gamma-radiation. The simulation was carried out using the Monte Carlo method. As a result, uncertainties of obtained conversion coefficients for dose rate estimations were evaluated.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [41] UNFOLDING TIME-DEPENDENT GAMMA-RAY PULSE HEIGHT SPECTRA BY VECTOR ANALYSIS
    SHARMA, RC
    NUCLEAR INSTRUMENTS & METHODS, 1968, 63 (01): : 75 - &
  • [42] COMPUTER CORRECTION FOR SHIFTS IN GAIN AND BASELINE IN GAMMA-RAY SCINTILLATION PULSE HEIGHT SPECTRA
    COVELL, DF
    NUCLEAR INSTRUMENTS & METHODS, 1965, 36 (02): : 229 - &
  • [43] Spectra of GRB970228 from the transient gamma-ray spectrometer
    Palmer, DM
    Cline, TL
    Gehrels, N
    Hurley, K
    Kurczynski, P
    Madden, N
    Pehl, R
    Ramaty, R
    Seifert, H
    Teegarden, BJ
    GAMMA-RAY BURSTS, PTS 1 AND 2, 1998, (428): : 304 - 308
  • [44] Monte Carlo determination of gamma-ray dose rate with the GEANT system
    Likar, A
    Vidmar, T
    Pucelj, B
    HEALTH PHYSICS, 1998, 75 (02): : 165 - 169
  • [45] Research on source of high dose rate gamma-ray with short pulse duration
    Kuai, Bin
    Qiu, Ai-Ci
    Zeng, Zheng-Zhong
    Cong, Pei-Tian
    Wang, Liang-Ping
    Liang, Tian-Xue
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2005, 17 (04): : 595 - 598
  • [46] Pulse Deficit Correction Trigger for Planar CdTe Based Gamma-ray Spectrometer
    Eames, Dexter A.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3778 - 3780
  • [47] Automated spectroscopy of X-ray and gamma-ray pulse height spectra using energy space subdivision
    McClanahan, T
    Trombka, J
    Loew, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 176 - 179
  • [48] High resolution GRB spectra from the Transient Gamma-Ray Spectrometer (TGRS)
    Palmer, DM
    Seifert, H
    Teegarden, BJ
    Gehrels, N
    Cline, TL
    Ramaty, R
    Hurley, K
    Pehl, R
    Madden, N
    Owens, A
    GAMMA-RAY BURSTS - 3RD HUNTSVILLE SYMPOSIUM, PTS 1 AND 2, 1996, (384): : 218 - 222
  • [49] ENERGY-DISTRIBUTION DETERMINATION OF COMPLEX GAMMA SPECTRA UP TO 8 MEV MAXIMUM ENERGY BASED ON MEASURED PULSE-HEIGHT DISTRIBUTIONS
    HORLBECK, B
    SPITZBARTH, D
    KERNENERGIE, 1987, 30 (02): : 89 - 94
  • [50] Committee classifier based on linear discriminant analysis for the detection of radioisotopes from airborne gamma-ray spectra
    Dess, Brian W.
    Small, Gary W.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2020, 217