Determination of the dose rate from the pulse-height spectra of an airborne gamma-ray spectrometer based on an unmanned aerial vehicle

被引:0
|
作者
Gavrilov, S. L. [1 ]
Pimenov, A. E. [1 ]
Shvedov, A. M. [1 ]
Aron, D. V. [1 ]
Dyakov, S. V. [1 ]
机构
[1] RAS, IBRAE, Moscow, Russia
关键词
621.039+51-73;
D O I
10.1007/s10512-024-01084-w
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the present study, data for converting the pulse-height spectra of an airborne gamma-ray spectrometer with a NaI (31 x 31 mm) detector to the dose rate values were obtained using the mathematical simulation. The results were tested using model tasks for determining pulse-height spectra at heights from 15 to 75 m. A point isotropic source of 60Co and the infinite contamination of the soil surface with 137Cs were considered as sources of gamma-radiation. The simulation was carried out using the Monte Carlo method. As a result, uncertainties of obtained conversion coefficients for dose rate estimations were evaluated.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [11] LINEAR ESTIMATION AND ANALYSIS OF GAMMA RAY PULSE-HEIGHT SPECTRA
    PASTERNACK, BS
    TECHNOMETRICS, 1962, 4 (04) : 565 - &
  • [12] UNFOLDING BISMUTH-GERMANATE PULSE-HEIGHT DISTRIBUTIONS TO DETERMINE GAMMA-RAY FLUX SPECTRA AND DOSE-RATES
    MOSS, CE
    DOWDY, EJ
    EVANS, AE
    HAMM, ME
    LUCAS, MC
    SHUNK, ER
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 219 (03): : 558 - 564
  • [13] Calibration of an airborne ?-ray spectrometer based on an unmanned aerial vehicle using a point source
    Qin, Guoxiu
    Xu, Youning
    Li, Fan
    Zhou, Wenping
    Li, Weizhe
    Zhao, Guozhi
    ANNALS OF NUCLEAR ENERGY, 2022, 178
  • [14] LEAST-SQUARES ANALYSIS OF TIME-DEPENDENT GAMMA-RAY PULSE-HEIGHT SPECTRA
    YAMAMOTO, S
    NUCLEAR INSTRUMENTS & METHODS, 1967, 52 (02): : 245 - &
  • [15] PULSE-HEIGHT ANALYSIS OF GAMMA-RAY SPECTRA OF SAMPLES CONTAINING VERY LOW LEVELS OF RADIOACTIVITY
    SCHONFELD, E
    NUCLEAR APPLICATIONS, 1967, 3 (10): : 635 - +
  • [16] RECOVERING PULSE-HEIGHT SPECTRA IN PRIORITY GAMMA-SPECTROMETER SIGNAL TRANSMISSION
    BUKHALO, OP
    MEASUREMENT TECHNIQUES USSR, 1991, 34 (10): : 1059 - 1063
  • [17] PULSE-HEIGHT SPECTRUM FROM A PHOTOMULTIPLIER TUBE UNDER DIRECT GAMMA-RAY ILLUMINATION
    GANGOPADHYAY, G
    BANERJEE, D
    BHATTACHARYA, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 186 - 188
  • [18] PCGAP:: Application to analyze gamma-ray pulse-height spectra on a personal computer under Windows NT®
    Killian, EW
    East, LV
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 233 (1-2) : 109 - 114
  • [19] PCGAP: Application to analyze gamma-ray pulse-height spectra on a personal computer under Windows NT®
    E. W. Killian
    L. V. East
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 233 : 109 - 114
  • [20] DETERMINATION OF DOSE EQUIVALENT FOR MONTE CARLO ANALYSIS OF PULSE-HEIGHT SPECTRA
    TURNER, JE
    BIRKHOFF, RD
    HAMM, RN
    ANDERSON, VE
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 205 - &