Feature Extraction for Polyp Detection in Wireless Capsule Endoscopy Video Frames

被引:0
|
作者
Delagah B. [1 ]
Hassanpour H. [1 ]
机构
[1] Image Processing and Data Mining Lab, Shahrood University of Technology, Shahrud
关键词
All Open Access; Hybrid Gold;
D O I
10.1155/2023/6076514
中图分类号
学科分类号
摘要
Wireless capsule endoscopy (WCE) is a technology for filming the gastrointestinal (GI) tract to find abnormalities such as tumors, polyps, and bleeding. This paper proposes a new method based on hand-crafted features to detect polyps in WCE frames. A polyp has a convex surface containing pixel values with a specified Gaussian distribution. If a polyp exists in the WCE image, edges will be seen at the border of the occupied area. Since WCE images often suffer from low illumination, a histogram equalization (HE) technique can be used to enhance the image. In this paper, we initially find probable polyp edges via thresholding. Then, we use the edges to find the region of interest (ROI). Then, the mean, standard deviation (STD), and division of mean by STD from the ROI are computed as features to discriminate between polyp and nonpolyp using a support vector machine (SVM). The evaluation results on the Kvasir-Capsule dataset show 99% accuracy for the proposed method in polyp detection. Furthermore, the proposed method runs at a real-time speed of ∼0.031 seconds detection for each image. © 2023 Bardia Delagah and Hamid Hassanpour.
引用
收藏
相关论文
共 50 条
  • [11] Principal Curvature Based Polyp Detection in Wireless Capsule Endoscopy Images
    Vani, V.
    Prashanth, K. V. Mahendra
    2017 INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN ELECTRONICS AND COMMUNICATION TECHNOLOGY (ICRAECT), 2017, : 5 - 10
  • [12] Colon capsule endoscopy for polyp detection
    Baker, Holly
    LANCET GASTROENTEROLOGY & HEPATOLOGY, 2021, 6 (03): : 167 - 167
  • [13] Removal of Non-informative Frames for Wireless Capsule Endoscopy Video Segmentation
    Sun, Zhe
    Li, Baopu
    Zhou, Ran
    Zheng, Huimin
    Meng, Max Q. -H
    2012 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS (ICAL), 2012, : 294 - 299
  • [14] Segmentation of bleeding regions in wireless capsule endoscopy for detection of informative frames
    Hajabdollahi, M.
    Esfandiarpoor, R.
    Khadivi, P.
    Soroushmehr, S. M. R.
    Karimi, N.
    Najarian, K.
    Samavi, S.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 53
  • [15] Automatic detection of informative frames from wireless capsule endoscopy images
    Bashar, M. K.
    Kitasaka, T.
    Suenaga, Y.
    Mekada, Y.
    Mori, K.
    MEDICAL IMAGE ANALYSIS, 2010, 14 (03) : 449 - 470
  • [16] Bleeding Frame and Region Detection in the Wireless Capsule Endoscopy Video
    Yuan, Yixuan
    Li, Baopu
    Meng, Max Q. -H.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (02) : 624 - 630
  • [17] Automatic detection of intestinal juices in Wireless Capsule Video Endoscopy
    Vilarino, F.
    Spyridonos, P.
    Pujol, O.
    Vitria, J.
    Radeva, P.
    de Iorio, F.
    18TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 4, PROCEEDINGS, 2006, : 719 - +
  • [18] Polyp Detection and Radius Measurement in Small Intestine Using Video Capsule Endoscopy
    Zhou, Mingda
    Bao, Guanqun
    Geng, Yishuang
    Alkandari, Bader
    Li, Xiaoxi
    2014 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2014), 2014, : 237 - 241
  • [19] A Comparative Study of Shape Features for Polyp Detection in Wireless Capsule Endoscopy Images
    Li, Baopu
    Meng, Max Q. -H.
    Xu, Lisheng
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3731 - +
  • [20] Computer-Aided System for Polyp Detection in Wireless Capsule Endoscopy Images
    El Ansari, Mohamed
    Charfi, Said
    2017 INTERNATIONAL CONFERENCE ON WIRELESS NETWORKS AND MOBILE COMMUNICATIONS (WINCOM), 2017, : 407 - 412