Stereotactic body radiation therapy for prostate cancer: a dosimetric comparison of IMRT and VMAT using flattening filter and flattening filter-free beams

被引:0
|
作者
El-Sayed, Sherif M. [1 ,2 ]
El-Gebaly, Reem H. [1 ]
Fathy, Mohamed M. [1 ]
Abdelaziz, Dina M. [2 ,3 ]
机构
[1] Cairo Univ, Fac Sci, Biophys Dept, Giza 12613, Egypt
[2] Baheya Hosp, Radiotherapy Dept, Giza, Egypt
[3] NCI, Radiotherapy & Nucl Med Dept, Cairo, Egypt
关键词
Prostate cancer; Stereotactic body radiation therapy (SBRT); IMRT; VMAT; Flattening filter-free (FFF); Dosimetric comparison; MODULATED ARC THERAPY; RADIOTHERAPY; SBRT; RISK;
D O I
10.1007/s00411-024-01078-z
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This retrospective study was performed to evaluate plan quality and treatment delivery parameters of stereotactic body radiation therapy (SBRT) for prostate cancer. The study utilized different isocentric modulated techniques: intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using 6 MV flattening filter (FF) and 10 MV flattening filter-free beams (FFF). Fifteen retrospective prostate cancer patients were selected for this study. Sixty plans were created with an SBRT-prescribed dose of 36.25 Gy delivered in five fractions. Planning target volume (PTV) coverage, plan quality indices, doses delivered to organs at risk (OARs), and treatment delivery parameters were compared for all plans. It turned out that VMAT plans, particularly those using the FFF beam, provided superior target conformality and a steeper dose gradient as compared to IMRT plans. Additionally, VMAT plans showed better OARs sparing compared to IMRT plans. However, IMRT plans delivered a lower maximum dose to the target than VMAT plans. Importantly, the VMAT plans resulted in reduced treatment delivery parameters, including beam on time (BOT), monitor unit (MU), and modulation factor (MF), compared to IMRT plans. Furthermore, a statistically significant difference was observed in BOT and mean body dose between FF and FFF beams, with FFF beams showing superior performance. Considering all results, VMAT using 10 MV (FFF) is suggested for treating prostate cancer patients with SBRT. This offers the fastest delivery in addition to maintaining the highest plan quality.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 50 条
  • [31] Dosimetric comparison of flattened and flattening filter-free beams for liver stereotactic body irradiation in deep inspiration breath hold, and free breathing conditions
    Munirathinam, N.
    Pawaskar, P. N.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 169 - 174
  • [32] Dosimetric Evaluation of Flattening Filter-free (FFF) Photon Beams for Lung SBRT
    Chen, Q.
    Cai, J.
    Wu, Q.
    Yin, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S609 - S609
  • [33] Identification of the suitable leaf margin for liver stereotactic body radiotherapy with flattening filter-free beams
    Ogata, Toshiyuki
    Nishimura, Hideki
    Mayahara, Hiroshi
    Uehara, Kazuyuki
    Okayama, Takanobu
    [J]. MEDICAL DOSIMETRY, 2017, 42 (04) : 268 - 272
  • [34] Three-dimensional dose comparison of flattening filter (FF) and flattening filter-free (FFF) radiation therapy by using NIPAM gel dosimetry
    Yao, Chun-Hsu
    Chang, Tung-Hao
    Lin, Chia-Chi
    Lai, Yuan-Chun
    Chen, Chin-Hsing
    Chang, Yuan-Jen
    [J]. PLOS ONE, 2019, 14 (02):
  • [35] Flattening filter free beams in SBRT and IMRT: Dosimetric assessment of peripheral doses
    Kragl, Gabriele
    Baier, Franziska
    Lutz, Steffen
    Albrich, David
    Dalaryd, Marten
    Kroupa, Bernhard
    Wiezorek, Tilo
    Knoos, Tommy
    Georg, Dietmar
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (02): : 91 - 101
  • [36] Flattening Filter Free VMAT for extreme hypofractionation of prostate cancer
    Ahlstrom, M.
    Benedek, H.
    Nilsson, P.
    Knoos, T.
    Ceberg, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S407 - S408
  • [37] FLATTENING FILTER FREE BEAMS IN IMRT AND SBRT: DOSIMETRIC ASSESSMENT OF PERIPHERAL DOSE
    Kragl, G.
    Baier, F.
    Lutz, S.
    Albrich, D.
    Kroupa, B.
    Wiezorek, T.
    Georg, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S152 - S153
  • [38] Dosimetric Comparison of Unmatched Flattening Filter-free and Flattened Beams in Volumetric Arc Therapy Plans for Head-and-neck Cancer
    Kumar, Arvind
    Sharma, Kiran
    Shan, Chandi Prasad
    Garg, Abhishek
    [J]. JOURNAL OF MEDICAL PHYSICS, 2023, 48 (04) : 338 - 344
  • [39] Stereotactic Body Radiation Therapy (SBRT) Using Respiratory-Gated Volumetric Modulated Arc Therapy (VMAT) With Flattening Filter Free (FFF) Beams
    Qian, J.
    Luxton, G.
    Mok, E.
    Wang, L.
    Maxim, P.
    Kielar, K.
    Atwood, T.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S851 - S852
  • [40] Dosimetric evaluation of different planning techniques based on flattening filter-free beams for central and peripheral lung stereotactic body radiotherapy
    Dwivedi, Shekhar
    Kansal, Sandeep
    Shukla, Jooli
    Bharati, Avinav
    Dangwal, Vinod Kumar
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (06)