Dosimetric evaluation of different planning techniques based on flattening filter-free beams for central and peripheral lung stereotactic body radiotherapy

被引:2
|
作者
Dwivedi, Shekhar [1 ,2 ,3 ]
Kansal, Sandeep [3 ]
Shukla, Jooli [4 ]
Bharati, Avinav [5 ]
Dangwal, Vinod Kumar [6 ]
机构
[1] Homi Bhabha Canc Hosp & Res Ctr, Tata Mem Ctr, Dept Med Phys, Mullanpur, India
[2] Homi Bhabha Canc Hosp & Res Ctr, Tata Mem Ctr, Dept Med Phys, Sangrur, India
[3] Maharaja Ranjit Singh Punjab Tech Univ, Dept Phys, Bathinda, India
[4] Dr Bhimrao Ambedkar Univ, Dept Phys, Agra, Uttar Pradesh, India
[5] Dr Ram Manohar Lohia Inst Med Sci, Dept Radiat Oncol, Lucknow, Uttar Pradesh, India
[6] Govt Med Coll, Dept Radiotherapy, Patiala, Punjab, India
关键词
FFF photon beam; planning techniques; VMAT; SBRT; Acuros XB; VOLUMETRIC MODULATED ARC; RADIATION-THERAPY; DOSE CONFORMITY; RADIOSURGERY; HETEROGENEITY; TUMORS;
D O I
10.1088/2057-1976/ac2f0d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to dosimetrically compare and evaluate the flattening filter-free (FFF) photon beam-based three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) for lung stereotactic body radiotherapy (SBRT). RANDO phantom computed tomography (CT) images were used for treatment planning. Gross tumor volumes (GTVs) were delineated in the central and peripheral lung locations. Planning target volumes (PTVs) was determined by adding a 5 mm margin to the GTV. 3DCRT, IMRT, and VMAT plans were generated using a 6-MV FFF photon beam. Dose calculations for all plans were performed using the anisotropic analytical algorithm (AAA) and Acuros XB algorithms. The accuracy of the algorithms was validated using the dose measured in a CIRS thorax phantom. The conformity index (CI), high dose volume (HDV), low dose location (D-2cm), and homogeneity index (HI) improved with FFF-VMAT compared to FFF-IMRT and FFF-3DCRT, while low dose volume (R-50%) and gradient index (GI) showed improvement with FFF-3DCRT. Compared with FFF-3DCRT, a drastic decrease in the mean treatment time (TT) value was observed with FFF-VMAT for different lung sites between 57.09% and 60.39%, while with FFF-IMRT it increased between 10.78% and 17.49%. The dose calculation with Acuros XB was found to be superior to that of AAA. Based on the comparison of dosimetric indices in this study, FFF-VMAT provides a superior treatment plan to FFF-IMRT and FFF-3DCRT in the treatment of peripheral and central lung PTVs. This study suggests that Acuros XB is a more accurate algorithm than AAA in the lung region.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dosimetric Study of Stereotactic Body Radiotherapy Using Flattening Filter Free Beams for Peripheral Lung Cancer
    Deng, C.
    Zhang, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Dosimetric impact of flattening filter and flattening filter-free beams on IMRT planning of NSCLC
    Lee, S. W. Y.
    Or, K. M. K.
    Kwong, Y. P. J.
    Choy, Y. H. S.
    Kwong, C. Y. K.
    Keung, H. K.
    Wu, V. W. C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S485 - S486
  • [3] Dosimetric Evaluation of Flattening Filter-free (FFF) Photon Beams for Lung SBRT
    Chen, Q.
    Cai, J.
    Wu, Q.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S609 - S609
  • [4] Stereotactic body radiotherapy with volumetric intensity-modulated arc therapy and flattening filter-free beams: dosimetric considerations
    Mark Christoph Brekner
    Detlef Imhoff
    Claus Rödel
    Natalie Filmann
    Jörg Licher
    Ulla Ramm
    Janett Köhn
    Strahlentherapie und Onkologie, 2024, 200 : 346 - 357
  • [5] Stereotactic body radiotherapy with volumetric intensity-modulated arc therapy and flattening filter-free beams: dosimetric considerations
    Brekner, Mark Christoph
    Imhoff, Detlef
    Roedel, Claus
    Filmann, Natalie
    Licher, Joerg
    Ramm, Ulla
    Koehn, Janett
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (04) : 346 - 357
  • [6] Dosimetric verification of stereotactic body radiation therapy for lung cancer treatment plans using flattening filter-free beams
    Zhang, Jiyong
    Wu, Vincent W.
    Lu, Jiayang
    Hong, Danli
    Lin, Zhixiong
    TUMORI JOURNAL, 2015, 101 (06): : 631 - 636
  • [7] Identification of the suitable leaf margin for liver stereotactic body radiotherapy with flattening filter-free beams
    Ogata, Toshiyuki
    Nishimura, Hideki
    Mayahara, Hiroshi
    Uehara, Kazuyuki
    Okayama, Takanobu
    MEDICAL DOSIMETRY, 2017, 42 (04) : 268 - 272
  • [8] A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams
    Zhang, Ji-Yong
    Lu, Jia-Yang
    Wu, Li-Li
    Hong, Dan-Li
    Ma, Chang-chun
    Peng, Xun
    Lin, Zhi-Xiong
    ONCOTARGET, 2016, 7 (45) : 73792 - 73799
  • [9] Stereotactic body radiation therapy for prostate cancer: a dosimetric comparison of IMRT and VMAT using flattening filter and flattening filter-free beams
    El-Sayed, Sherif M.
    El-Gebaly, Reem H.
    Fathy, Mohamed M.
    Abdelaziz, Dina M.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 423 - 431
  • [10] Optimization of leaf margins for lung stereotactic body radiotherapy using a flattening filter-free beam
    Wakai, Nobuhide
    Sumida, Iori
    Otani, Yuki
    Suzuki, Osamu
    Seo, Yuji
    Isohashi, Fumiaki
    Yoshioka, Yasuo
    Hasegawa, Masatoshi
    Ogawa, Kazuhiko
    MEDICAL PHYSICS, 2015, 42 (05) : 2125 - 2131