A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams

被引:5
|
作者
Zhang, Ji-Yong [1 ]
Lu, Jia-Yang [1 ]
Wu, Li-Li [1 ]
Hong, Dan-Li [2 ]
Ma, Chang-chun [1 ]
Peng, Xun [1 ]
Lin, Zhi-Xiong [1 ]
机构
[1] Shantou Univ, Coll Med, Canc Hosp, Dept Radiat Oncol, Shantou 515031, Peoples R China
[2] Shantou Univ, Coll Med, Affiliated Hosp 1, Dept Endocrinol, Shantou 515031, Peoples R China
关键词
dosimetric benefits; stereotactic body radiation therapy; flattening filter free beams; lung cancer; MODULATED ARC THERAPY; CONFORMAL ARC; TREATMENT PLANS; RADIOTHERAPY; DELIVERY; I/II; SBRT;
D O I
10.18632/oncotarget.12071
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To investigate potential dosimetric benefits and treatment efficiency of dynamic conformal arc therapy (DCA), intensity modulated radiation therapy (IMRT), and double partial arcs Rapidarc (RA) techniques in the treatment of early-stage peripheral lung cancer using stereotactic body radiotherapy (SBRT) with flattening filter free (FFF) beams. Twenty early-stage peripheral lung cancer patients were selected. For each patient, DCA, IMRT and RA plans were created to meet Radiation Therapy Oncology Group (RTOG) 0915 objectives with 48 Gy covering 95% of the planning target volume (PTV) in 4 fractions. PTV coverage, organs at risk (OARs) doses, planning time, monitor units (MU) and treatment time were evaluated. RA was significantly better than DCA for PTV coverage. RA provided a lower V-32Gy to chest wall and less V-20Gy to lung over those of DCA and IMRT. For other OARs, there is no significant difference among all three techniques. DCA plans showed significantly less planning time, shorter treatment time and lower MU number than those of RA and IMRT. RA provides a superior dosimetric benefit to DCA and IMRT in the treatment of early-stage lung cancer using SBRT with FFF beams. Considering the MU number, planning time and treatment efficiency, DCA technique is an effective treatment strategy.
引用
收藏
页码:73792 / 73799
页数:8
相关论文
共 50 条
  • [1] Dosimetric verification of stereotactic body radiation therapy for lung cancer treatment plans using flattening filter-free beams
    Zhang, Jiyong
    Wu, Vincent W.
    Lu, Jiayang
    Hong, Danli
    Lin, Zhixiong
    [J]. TUMORI JOURNAL, 2015, 101 (06): : 631 - 636
  • [2] Dosimetric Study of Stereotactic Body Radiotherapy Using Flattening Filter Free Beams for Peripheral Lung Cancer
    Deng, C.
    Zhang, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Stereotactic body radiation therapy for prostate cancer: a dosimetric comparison of IMRT and VMAT using flattening filter and flattening filter-free beams
    El-Sayed, Sherif M.
    El-Gebaly, Reem H.
    Fathy, Mohamed M.
    Abdelaziz, Dina M.
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 423 - 431
  • [4] Investigating flattening filter free mode for peripheral lung stereotactic body radiation therapy
    Jensen, Michael
    Garcia, Lourdes M.
    Scora, Daryl
    Vandermeer, Aaron
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4378 - 4378
  • [5] Flattening Filter Free vs. Flattened Beams for Lung Stereotactic Body Radiation Therapy
    Annede, Pierre
    Darreon, Julien
    Benkemouche, Ahcene
    Valdenaire, Simon
    Tyran, Marguerite
    Kaeppelin, Bertrand
    Macagno, Alban
    Barrou, Julien
    Cagetti, Leonel Varela
    Favrel, Veronique
    Moureau-Zabotto, Laurence
    Gonzague, Laurence
    Fau, Pierre
    Chargari, Cyrus
    Tallet, Agnes
    Salem, Naji
    [J]. ANTICANCER RESEARCH, 2017, 37 (09) : 5133 - 5139
  • [6] Dosimetric evaluation of different planning techniques based on flattening filter-free beams for central and peripheral lung stereotactic body radiotherapy
    Dwivedi, Shekhar
    Kansal, Sandeep
    Shukla, Jooli
    Bharati, Avinav
    Dangwal, Vinod Kumar
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (06)
  • [7] Monte Carlo evaluation of target dose coverage in lung stereotactic body radiation therapy with flattening filter-free beams
    Vassiliev, Oleg N.
    Peterson, Christine B.
    Chang, Joe Y.
    Mohan, Radhe
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 81 - 87
  • [8] Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations
    Mancosu, Pietro
    Castiglioni, Simona
    Reggiori, Giacomo
    Catalano, Maddalena
    Alongi, Filippo
    Pellegrini, Chiara
    Arcangeli, Stefano
    Tozzi, Angelo
    Lobefalo, Francesca
    Fogliata, Antonella
    Navarria, Piera
    Cozzi, Luca
    Scorsetti, Marta
    [J]. RADIATION ONCOLOGY, 2012, 7
  • [9] Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations
    Pietro Mancosu
    Simona Castiglioni
    Giacomo Reggiori
    Maddalena Catalano
    Filippo Alongi
    Chiara Pellegrini
    Stefano Arcangeli
    Angelo Tozzi
    Francesca Lobefalo
    Antonella Fogliata
    Piera Navarria
    Luca Cozzi
    Marta Scorsetti
    [J]. Radiation Oncology, 7
  • [10] Flattening filter-free linac improves treatment delivery efficiency in stereotactic body radiation therapy
    Prendergast, Brendan M.
    Fiveash, John B.
    Popple, Richard A.
    Clark, Grant M.
    Thomas, Evan M.
    Minnich, Douglas J.
    Jacob, Rojymon
    Spencer, Sharon A.
    Bonner, James A.
    Dobelbower, Michael C.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 64 - 71