X-Ray Image Generation as a Method of Performance Prediction for Real-Time Inspection: a Case Study

被引:0
|
作者
Andriiashen, Vladyslav [1 ]
van Liere, Robert [1 ,2 ]
van Leeuwen, Tristan [1 ,3 ]
Batenburg, K. Joost [1 ,4 ]
机构
[1] Ctr Wiskunde Informat, Computat Imaging, Sci Pk 123, NL-1098 XG Amsterdam, Netherlands
[2] Tech Univ Eindhoven, Fac Wiskunde Informat, Groene Loper 5, NL-5612 AZ Eindhoven, Netherlands
[3] Univ Utrecht, Math Inst, Budapestlaan 6, NL-3584 CD Utrecht, Netherlands
[4] Leiden Univ, Leiden Inst Adv Comp Sci, Niels Bohrweg 1, NL-2333 CA Leiden, Netherlands
关键词
X-ray inspection; System Design; Dual-energy X-ray; Deep Convolutional neural networks; Probability of detection; NOISE; OPTIMIZATION; SIMULATION; CT;
D O I
10.1007/s10921-024-01091-8
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
X-ray imaging can be efficiently used for high-throughput in-line inspection of industrial products. However, designing a system that satisfies industrial requirements and achieves high accuracy is a challenging problem. The effect of many system settings is application-specific and difficult to predict in advance. Consequently, the system is often configured using empirical rules and visual observations. The performance of the resulting system is characterized by extensive experimental testing. We propose to use computational methods to substitute real measurements with generated images corresponding to the same experimental settings. With this approach, it is possible to observe the influence of experimental settings on a large amount of data and to make a prediction of the system performance faster than with conventional methods. We argue that a high accuracy of the image generator may be unnecessary for an accurate performance prediction. We propose a quantitative methodology to characterize the quality of the generation model using Probability of Detection curves. The proposed approach can be adapted to various applications and we demonstrate it on the poultry inspection problem. We show how a calibrated image generation model can be used to quantitatively evaluate the effect of the X-ray exposure time on the performance of the inspection system.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Registration of real-time X-ray image sequences for weld inspection
    Du, Dong
    Hou, Runshi
    Shao, Jiaxin
    Chang, Baohua
    Wang, Li
    NONDESTRUCTIVE TESTING AND EVALUATION, 2010, 25 (02) : 153 - 159
  • [2] Real-time X-ray inspection for aerospace applications
    Drake, S
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2003, 75 (04): : 386 - 389
  • [3] A real-time multisensory image segmentation algorithm with an application to visual and x-ray inspection
    Ding, YH
    Vachtsevanos, GJ
    Yezzi, AJ
    Daley, W
    Heck-Ferri, BS
    COMPUTER VISION SYSTEMS, PROCEEDINGS, 2003, 2626 : 192 - 201
  • [4] X-RAY REAL-TIME IMAGING FOR WELD INSPECTION.
    Anon
    Welding in the World, Le Soudage Dans Le Monde, 1986, 24 (1-2): : 2 - 9
  • [5] Real time x-ray inspection
    Heidt, H.
    Proceedings of the International Institute of Welding Congress on Joining Research, 1990,
  • [6] REAL-TIME TOPOGRAPHY WITH X-RAY IMAGE MAGNIFICATION
    BOETTINGER, WJ
    DOBBYN, RC
    BURDETTE, HE
    KURIYAMA, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2): : 355 - 361
  • [7] Parametrized System Level Design: Real-Time X-Ray Image Processing Case Study
    Shoshkov, Tsvetan
    Stefanov, Todor
    Kienhuis, Bart
    2016 IEEE 27TH INTERNATIONAL CONFERENCE ON APPLICATION-SPECIFIC SYSTEMS, ARCHITECTURES AND PROCESSORS (ASAP), 2016, : 196 - 201
  • [8] Automatic inspection of weld defects with x-ray real-time imaging
    Dong, Du
    Guo-Rui, Cai
    Yuan, Tian
    Run-Shi, Hou
    Li, Wang
    ROBOTIC WELDING, INTELLIGENCE AND AUTOMATION, 2007, 362 : 359 - +
  • [9] A real-time weld defect inspection system in X-ray images
    Sun, Y
    Wang, EL
    Zhou, P
    Li, M
    OPTICAL INFORMATION PROCESSING TECHNOLOGY, 2002, 4929 : 282 - 287
  • [10] Real-time image equalization for coronary X-ray angiography
    Robert, N
    Komljenovic, PT
    Fort, S
    Rowlands, JA
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (02) : 288 - 294