Biomechanical Behavior of an Hydroxyapatite-Coated Traditional Hip Stem and a Short One of Similar Design: Comparative Study Using Finite Element Analysis

被引:6
|
作者
Gomez-Vallejo, Jesus [1 ]
Roces-Garcia, Jorge [2 ]
Moreta, Jesus [3 ]
Donaire-Hoyas, Daniel [4 ]
Gayoso, Oscar [5 ]
Marques-Lopez, Fernando [6 ]
Albareda, Jorge [1 ]
机构
[1] Hosp Clin Univ Lozano Blesa, Dept Orthopaed Surg, Zaragoza, Spain
[2] Univ Oviedo, Dept Construct & Mfg Engn, Oviedo, Spain
[3] Hosp Galdakao Usansolo, Dept Orthopaed Surg & Traumatol, Biocruces Bizkaia Hlth Res Inst, Grp Lower Limb Reconstruct Surg,Osakidetza, Bizkaia, Spain
[4] Hosp Poniente, Dept Orthopaed Surg, El Ejido, Spain
[5] Hosp San Rafael, Dept Orthopaed Surg, La Coruna 08035, Spain
[6] Parc Salut Mar, Hip Reconstruct Unit, Barcelona, Spain
来源
ARTHROPLASTY TODAY | 2021年 / 7卷
关键词
Hip; Biomechanics; Short stem; Finite elements; Loading; THR; QUANTITATIVE COMPUTED-TOMOGRAPHY; FEMORAL COMPONENT; PRIMARY STABILITY; BONE; ARTHROPLASTY; REPLACEMENT; STRESS; MICROMOTION; PATTERNS; STRAIN;
D O I
10.1016/j.artd.2020.11.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The objective is to compare, by the means of finite elements analysis, the biomechanical behavior of a conventional stem of proven performance with a short stem based on the same fixation principles.Methods: A 3D femur was modeled from CT scan data, and real bone density measures were incorporated into it. Load stresses were applied to that bone in 3 different scenarios: without prosthesis, with the conventional stem, and with the short stem. Different bone loading patterns were compared by Gruen's zones both visually and statistically using Welch's test.Results: The implantation of a stem generates a certain degree of stress shielding in the surrounding bone, but the pattern of the change is very similar in the compared stem models. Although there is statistical significance (P < 0.01) in the mean stress variation in most of the Gruen's zones, the magnitude of the difference is always under 2 MPa (range: 0.01 1.74 MPa).Conclusions: The bone loading patterns of the traditional stem and the short stem are very similar. Although there is no evidence of a link between biomechanics and clinical outcomes, our results may suggest that theoretical advantages of short stems can be exploited without the fear of altering bone loading patterns.(c) 2020 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页码:167 / 176
页数:10
相关论文
共 33 条
  • [21] Comparative analysis of the biomechanical behavior of two different design metaphyseal-fitting short stems using digital image correlation
    Tatani, I.
    Megas, P.
    Panagopoulos, A.
    Diamantakos, I.
    Nanopoulos, Ph.
    Pantelakis, Sp.
    BIOMEDICAL ENGINEERING ONLINE, 2020, 19 (01)
  • [22] Comparative analysis of the biomechanical behavior of two different design metaphyseal-fitting short stems using digital image correlation
    I. Tatani
    P. Megas
    A. Panagopoulos
    I. Diamantakos
    Ph. Nanopoulos
    Sp. Pantelakis
    BioMedical Engineering OnLine, 19
  • [23] Study on the mechanical behavior of one-side strengthened reinforced concrete columns using finite element analysis
    Li, Zhenbao
    Chen, Lei
    Ma, Hua
    Fu, Jing
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2014, 47 : 36 - 41
  • [24] Patient specific parametric geometric modelling and finite element analysis of cementless hip prosthesis This paper proposes a framework for subject-specific cementless hip implant design and virtual assembly analysis of the instantiated stem with femur model using finite element method
    George, Subin P.
    Kumar, Gurunathan Saravana
    VIRTUAL AND PHYSICAL PROTOTYPING, 2013, 8 (01) : 65 - 83
  • [25] Biomechanical comparative finite element analysis between a conventional proximal interphalangeal joint flexible hinge implant and a novel implant design using a rolling contact joint mechanism
    Kim, Yong-Jae
    Bae, Hyun-ah
    Hong, Seok Woo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [26] Biomechanical comparative finite element analysis between a conventional proximal interphalangeal joint flexible hinge implant and a novel implant design using a rolling contact joint mechanism
    Yong-Jae Kim
    Hyun-ah Bae
    Seok Woo Hong
    Journal of Orthopaedic Surgery and Research, 18
  • [27] Biomechanical behavior of cavity design on teeth restored using ceramic inlays: An approach based on three-dimensional finite element analysis and ultrahigh-speed camera
    Cheng, Chun-Wen
    Chen, Weng-Pin
    Chien, Yu-Ting
    Teng, Yu-Ting
    Lu, Pei-Ying
    Huang, Shih-Hao
    Lin, Po-Yen
    Chiang, Yu-Chih
    ACTA BIOMATERIALIA, 2019, 89 : 382 - 390
  • [28] Comparison of two metaphyseal-fitting (short) femoral stems in primary total hip arthroplasty: study protocol for a prospective randomized clinical trial with additional biomechanical testing and finite element analysis
    I. Tatani
    A. Panagopoulos
    I. Diamantakos
    G. Sakellaropoulos
    Sp Pantelakis
    P. Megas
    Trials, 20
  • [29] Comparison of two metaphyseal-fitting (short) femoral stems in primary total hip arthroplasty: study protocol for a prospective randomized clinical trial with additional biomechanical testing and finite element analysis
    Tatani, I.
    Panagopoulos, A.
    Diamantakos, I.
    Sakellaropoulos, G.
    Pantelakis, Sp
    Megas, P.
    TRIALS, 2019, 20 (1)
  • [30] A COMPARATIVE STUDY BETWEEN SMALL TRADITIONAL INDUCTION MOTORS AND SMALL CONDUCTING SLEEVE INDUCTION MOTORS USING 3D FINITE ELEMENT TRANSIENT ANALYSIS
    Hosseini, Seyed Mohsen
    Moghani, Javad S.
    Hosseini, Akram
    ECT 2009: ELECTRICAL AND CONTROL TECHNOLOGIES, 2009, : 251 - 255