TWO-PHASE FLOW METERING OF MALDISTRIBUTION INSIDE A HEADER BY MEANS OF VENTURI FLOWMETER SOLELY

被引:0
|
作者
Lecardonnel A. [1 ,2 ]
De Servi C. [2 ]
Colonna P. [2 ]
Laboureur D. [1 ]
机构
[1] Von Karman Institute for Fluid Dynamics, Rhode-St-Genese
[2] Delft University of Technology, Delft
基金
欧盟地平线“2020”;
关键词
evaporators; experimental; heat exchanger; liquid-gas two-phase flow; maldistribution; metering instrumentation; Venturi;
D O I
10.1615/MultScienTechn.2023048066
中图分类号
学科分类号
摘要
In evaporators, the distribution of the liquid and vapor phases among the channels is a convoluted problem, depending on a wide range of parameters. However, maldistribution causes important losses of performance. Due to their complexity, the accurate modeling of such two-phase flows is difficult to handle. Hence, experimental studies are still of great importance to help the understanding of maldistribution behaviors inside evaporators. Most of the experimental investigations of two-phase flow distribution are measuring the liquid and vapor quantities in the channels through a phase separation process, increasing the test duration and complexity. As a consequence, the number of parameters investigated is usually limited. Therefore, a new inline instrumentation method would allow for a more complete study by simplifying the measurement process. In the present work, an isothermal air/water mixture was used as fluid. The distribution of the two phases in eight channels of 10-mm I.D. connected to a simplified header was investigated. The inlet mass flow rates considered ranged from 0 to 0.025 kg/s for the water, and from 0 to 0.022 kg/s for the air. Consequently, qualities x up to 0.7 and void fractions ® up to 0.9 were reached. All the tests were carried at a pressure condition of 7 bar to reach a liquid to vapor density ratio similar to what is encountered for traditional refrigerant. Finally, to allow a continuous measurement process, the mass flow rates in each of the 10-mm I.D. channel were measured using a flowmeter calibrated on a separate line. Since no void fraction meter was coupled, a new iterative methodology, based on the Venturi pressure drops measurement solely, was developed and is proposed here. It proved to successfully predict the vapor and liquid phase flow rates in each channel. © 2024 by Begell House, Inc.
引用
收藏
页码:97 / 114
页数:17
相关论文
共 50 条
  • [31] Liquid blockage and flow maldistribution of two-phase flow in two parallel thin micro-channels
    Wu, Jingtian
    Wang, Yun
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [32] CFD SIMULATION OF TWO-PHASE FLOW IN A LARGE SCALE VENTURI SCRUBBER
    Teixeira, Senhorinha F. C.
    Silva, Angela
    Teixeira, Jose C.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2013, VOL 1C: SYMPOSIA, 2014,
  • [33] A comprehensive assessment of correlations for two-phase flow through Venturi tubes
    Liu, Xiaolei
    Lao, Liyun
    Falcone, Gioia
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2020, 78
  • [34] Two-phase flow measurements at high void fraction by a Venturi meter
    Monni, Grazia
    De Salve, Mario
    Panella, Bruno
    PROGRESS IN NUCLEAR ENERGY, 2014, 77 : 167 - 175
  • [35] Heat-triggered two-phase flow maldistribution in a micromachined cryogenic cooler
    Cao, H. S.
    Vanapalli, S.
    Holland, H. J.
    Vermeer, C. H.
    ter Brake, H. J. M.
    CRYOGENICS, 2020, 106
  • [36] Complex signal processing for Coriolis mass flow metering in two-phase flow
    Li, Ming
    Henry, Manus
    FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 64 : 104 - 115
  • [37] Two-phase flow and maldistribution in gas channels of a polymer electrolyte fuel cell
    Basu, Suman
    Li, Jun
    Wang, Chao-Yang
    JOURNAL OF POWER SOURCES, 2009, 187 (02) : 431 - 443
  • [38] Stability analysis and maldistribution control of two-phase flow in parallel evaporating channels
    Zhang, TieJun
    Wen, John T.
    Julius, Agung
    Peles, Yoav
    Jensen, Michael K.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (25-26) : 5298 - 5305
  • [39] TWO-PHASE REFRIGERANT MALDISTRIBUTION IN THE VERTICAL HEADER AND ITS EFFECT ON THE HEAT EXCHANGER PERFORMANCE AS EVAPORATOR IN HEAT PUMP MODE
    Zou, Yang
    Tuo, Hanfei
    Hrnjak, Predrag S.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 1823 - 1832
  • [40] Interaction of density wave oscillations and flow maldistribution for two-phase flow boiling parallel channels
    Paul, Deepraj
    Singh, Suneet
    Mishra, Surendra
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 145