Two-phase flow measurements at high void fraction by a Venturi meter

被引:21
|
作者
Monni, Grazia [1 ]
De Salve, Mario [1 ]
Panella, Bruno [1 ]
机构
[1] Politecn Torino, Dept Energy, I-10129 Turin, Italy
关键词
Venturi flow meter; Pressure losses; Two-phase flow rates; Annular flow;
D O I
10.1016/j.pnucene.2014.06.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An experimental investigation of a vertical upward annular two-phase flow across a Venturi flow meter has been performed for the measurement of two-phase flow parameters with reference to the experimental simulation of nuclear accidents, as LOCA, characterized by very high void fraction. The pressure drops between the inlet and throat section and between inlet and outlet (irreversible pressure losses) have been measured and analyzed. The Venturi flow meter is characterized by an inlet diameter of 80 mm and a throat diameter of 40 mm (beta = 0.5), with equal convergent and divergent angles (theta = 21 degrees). The instrument has been tested in a test section having an internal diameter (D-i) of 80 mm and a total length (L) of about 4 m, with air water two-phase flow at ambient pressure. The air superficial velocity ranged between 14 and 18 m/s while the water superficial velocity ranged between 0.0008 and 0.005 m/s, so that the flow pattern was annular and the corresponding flow quality ranged between 0.78 and 0.96. The dependence of the pressure drops on the phases velocities has been analyzed and modeled as a function of the superficial velocities of the phases, and the mass flow rate of the two phases has been derived from the present test data when the annular flow pattern does not change in a significant way. The flow quality can be evaluated with an accuracy of 5% and the mass flow rate of air and water can be estimated with an accuracy better than 2% and 30% respectively. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 50 条
  • [1] Performance of a venturi flow meter in two-phase helium flow
    Huang, X
    VanSciver, SW
    CRYOGENICS, 1996, 36 (04) : 303 - 309
  • [2] Experimental and numerical development of a two-phase Venturi flow meter
    Rosa, ES
    Morales, REM
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (03): : 457 - 467
  • [3] CFD Simulation of Two-phase Flow in a Downhole Venturi Meter
    Feng Ding
    Huang Si
    Guan Yuhui
    Ma Weiguo
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 3644 - +
  • [4] DEVELOPMENT OF A CAPACITANCE BASED VOID FRACTION SENSOR FOR TWO-PHASE FLOW MEASUREMENTS
    Hewlin, Rodward L., Jr.
    Kizito, John P.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2013, VOL 2: FORA, 2014,
  • [5] GENETIC ALGORITHMS APPLIED TO FLOW ESTIMATION IN A TWO-PHASE FLOW WITH A VENTURI METER
    Borregales, Manuel A.
    Nunez, Gilberto
    Cappelletto, Jose
    Asuaje, Miguel
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 7, 2015,
  • [6] Venturi flow meter and Electrical Capacitance Probe in a horizontal two-phase flow
    Monni, G.
    Caramello, M.
    De Salve, M.
    Panella, B.
    33RD UIT (ITALIAN UNION OF THERMO-FLUID DYNAMICS) HEAT TRANSFER CONFERENCE, 2015, 655
  • [7] Void fraction prediction in annular two-phase flow
    Cioncolini, Andrea
    Thome, John R.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2012, 43 : 72 - 84
  • [8] Measurements of two-phase flow patterns and local void fraction in vertical rectangular minichannel
    Kaniowski, Robert
    Poniewski, Mieczyslaw
    ARCHIVES OF THERMODYNAMICS, 2013, 34 (02) : 3 - 21
  • [9] Correlations of void fraction for two-phase refrigerant flow in pipes
    Xu, Yu
    Fang, Xiande
    APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 242 - 251
  • [10] Determination of Void Fraction of Two-Phase Flow in Slit Microchannel
    Dementyev, Yuriy
    Ronshin, Fedor
    THERMOPHYSICAL BASIS OF ENERGY TECHNOLOGIES (TBET 2019), 2020, 2212