Performance Analysis of R1234yf and R134a in a Multi-Evaporator with Individual Expansion Valve in a Single Compression System

被引:0
|
作者
Riyami H.A. [1 ]
Solomon G.R. [1 ]
Ravikumar T.S. [1 ]
Balaji D. [1 ]
Hariram V. [1 ]
机构
[1] Dept. of Mech. Engg, Hindustan Institute of Tech. & Sci, Padur, Tamil Nadu, Chennai
关键词
Coefficient of performance; Compressor works; Discharge temperature; Refrigeration;
D O I
10.4273/ijvss.15.4.15
中图分类号
学科分类号
摘要
The study aimed to compare the performance of R1234yf and R134a refrigeration systems based on Coefficient of Performance (COP) vs. time, refrigeration effect vs. time, compressor work vs. time and discharge temperature vs. time. The R1234yf has been proposed as the better alternative to R134a. However, the results suggest that both systems have advantages and disadvantages, making it difficult to justify the suitability of R1234yf over R134a. The performances were analysed at different heat loads ranging from 0W, 600W, 800W, 1000W and 1200W. The results show that highest performance was recorded at 1200W heat load. In addition, there were significant differences between the two systems. The discharge temperature for R1234yf was about 9% higher than R134a. Similarly, R134a performed better regarding compressor work vs. time. Respectively, R134a performed better in COP vs. time and refrigeration effects vs. time. There was a significant difference in the refrigeration effects and COP for the two systems. Also, the differences in COP and refrigeration effects increased with the heat loads. The lower COP in the R1234yf suggested that it could consume a lot of energy and thus making it unsustainable. The study concluded that the efficiency of the two systems varies; therefore, having a system that is a mixture of the two can help improve refrigeration efficiency and reduce pollution. However, further exploration of the two systems is needed to determine their efficiencies under different conditions before making a conclusive recommendation. The selected system should have minimal effects on the environment and produce the highest refrigeration effects within a short time. © 2023. Carbon Magics Ltd.
引用
收藏
页码:534 / 539
页数:5
相关论文
共 50 条
  • [1] Theoretical analysis of R1234yf and R1234yf/R125 mixture as replacement of R134a in vapor compression system
    Lin, Yongmei
    Meng, Zhaofeng
    Huo, Ziheng
    Ding, Chuangchuang
    Wang, Song
    Wang, Longji
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 490 - 496
  • [2] Exergy analysis of R1234yf and R1234ze as R134a replacements in a two evaporator vapour compression refrigeration system
    Yataganbaba, Alptug
    Kilicarslan, Ali
    Kurtbas, Irfan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2015, 60 : 26 - 37
  • [3] Performance of Automotive Air Conditioning System with R134a and R1234yf
    Kuwar, Yogendra Vasantrao
    Narasimham, G. S. V. L.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2020, 28 (02)
  • [4] Energy Analysis of R1234yf/R134a as Replacement of R134a in a Domestic Refrigerator
    Raveendran, P. Saji
    Murugan, P. C.
    Darwin, T.
    Glivin, Godwin
    Dwivedi, Gaurav
    ADVANCEMENT IN MATERIALS, MANUFACTURING AND ENERGY ENGINEERING, VOL. II, ICAMME 2021, 2022, : 495 - 502
  • [5] Experimental analysis of R1234yf as a drop-in replacement for R134a in a vapor compression system
    Navarro-Esbri, J.
    Mendoza-Miranda, J. M.
    Mota-Babiloni, A.
    Barragan-Cervera, A.
    Belman-Flores, J. M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 870 - 880
  • [6] Performance improvement strategies of R1234yf in vapor compression refrigeration system as a R134a replacement: A review
    Sharif, M. Z.
    Azmi, W. H.
    Ghazali, M. F.
    Samykano, M.
    Ali, Hafiz Muhammad
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 148
  • [7] Computational energy and exergy analysis of R134a, R1234yf, R1234ze and their mixtures in vapour compression system
    Gaurav
    Kumar, Raj
    AIN SHAMS ENGINEERING JOURNAL, 2018, 9 (04) : 3229 - 3237
  • [8] Performance analysis of refrigerants R134a and R1234yf two stage compression cycle with two condensers
    Wang, Hongli
    Tang, Qilong
    Jia, Ning
    Zhang, Qinghua
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2778 - +
  • [9] Experimental Performance Analysis of R1234yf in an Air-Conditioning System as Substitute of R134a
    Medany, M. M.
    El Morsi, M.
    El-Sayed, A. R.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (04)
  • [10] R1234yf vs R134a in automotive air conditioning system: A comparison of the performance
    Sharif, M. Z.
    Azmi, W. H.
    Zawawi, N. N. M.
    Mamat, R.
    Hamisa, A. H.
    SYMPOSIUM ON ENERGY SYSTEMS 2019 (SES 2019), 2020, 863