Performance Analysis of R1234yf and R134a in a Multi-Evaporator with Individual Expansion Valve in a Single Compression System

被引:0
|
作者
Riyami H.A. [1 ]
Solomon G.R. [1 ]
Ravikumar T.S. [1 ]
Balaji D. [1 ]
Hariram V. [1 ]
机构
[1] Dept. of Mech. Engg, Hindustan Institute of Tech. & Sci, Padur, Tamil Nadu, Chennai
关键词
Coefficient of performance; Compressor works; Discharge temperature; Refrigeration;
D O I
10.4273/ijvss.15.4.15
中图分类号
学科分类号
摘要
The study aimed to compare the performance of R1234yf and R134a refrigeration systems based on Coefficient of Performance (COP) vs. time, refrigeration effect vs. time, compressor work vs. time and discharge temperature vs. time. The R1234yf has been proposed as the better alternative to R134a. However, the results suggest that both systems have advantages and disadvantages, making it difficult to justify the suitability of R1234yf over R134a. The performances were analysed at different heat loads ranging from 0W, 600W, 800W, 1000W and 1200W. The results show that highest performance was recorded at 1200W heat load. In addition, there were significant differences between the two systems. The discharge temperature for R1234yf was about 9% higher than R134a. Similarly, R134a performed better regarding compressor work vs. time. Respectively, R134a performed better in COP vs. time and refrigeration effects vs. time. There was a significant difference in the refrigeration effects and COP for the two systems. Also, the differences in COP and refrigeration effects increased with the heat loads. The lower COP in the R1234yf suggested that it could consume a lot of energy and thus making it unsustainable. The study concluded that the efficiency of the two systems varies; therefore, having a system that is a mixture of the two can help improve refrigeration efficiency and reduce pollution. However, further exploration of the two systems is needed to determine their efficiencies under different conditions before making a conclusive recommendation. The selected system should have minimal effects on the environment and produce the highest refrigeration effects within a short time. © 2023. Carbon Magics Ltd.
引用
收藏
页码:534 / 539
页数:5
相关论文
共 50 条
  • [31] Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a
    Navarro-Esbri, Joaquin
    Moles, Francisco
    Barragan-Cervera, Angel
    APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) : 153 - 161
  • [32] Energy and exergy analysis of R1234yf as drop-in replacement for R134a in a domestic refrigeration system
    Belman-Flores, J. M.
    Rangel-Hernandez, V. H.
    Uson, S.
    Rubio-Maya, C.
    ENERGY, 2017, 132 : 116 - 125
  • [33] Experimental study on R1234yf/R134a mixture (R513A) as R134a replacement in a domestic refrigerator
    Yang, Meng
    Zhang, Hua
    Meng, Zhaofeng
    Qin, Yanbin
    APPLIED THERMAL ENGINEERING, 2019, 146 : 540 - 547
  • [34] Drop-in Performance Analysis and Effect of IHX for an Automotive Air Conditioning System with R1234yf as a Replacement of R134a
    Direk, Mehmet
    Kelesoglu, Alper
    Akin, Ahmet
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2017, 63 (05): : 314 - 319
  • [35] Experimental analysis of R1234yf as a drop-in replacement for R134a in a small power refrigerating system
    Sieres, Jaime
    Manuel Santos, Jose
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2018, 91 : 230 - 238
  • [36] Comparison of transient response of an evaporator model for water refrigeration system working with R1234yf as a drop-in replacement for R134a
    Garcia, Juan
    Ali, Thiago
    Duarte, Willian Moreira
    Khosravi, Ali
    Machado, Luiz
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 91 : 211 - 222
  • [37] R1234yf and R744 as alternatives to R134a at mobile air conditioners
    Onan C.
    Erdem S.
    Journal of Energy Systems, 2021, 5 (04): : 284 - 295
  • [38] Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator
    Rangel-Hernandez, V. H.
    Belman-Flores, J. M.
    Rodriguez-Valderrama, D. A.
    Pardo-Cely, D.
    Rodriguez-Munoz, A. P.
    Ramirez-Minguela, J. J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 113 - 123
  • [39] Experimental study on the flammability ofanew type of refrigerant R1234yf/R134a
    Chen, Guangming (gmchen@zju.edu.cn), 1600, Science Press (37):
  • [40] Performance analysis of refrigerants R1234yf single stage compression cycle with a throttle valve and an expander
    Tian, Jingrui
    Wang, Hongli
    Xue Guijun
    Zhang, Qinghua
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2790 - +