Liquid chromatography with tandem mass spectrometric method for determination of 52 antibiotics in human whole blood and urine and application to forensic cases

被引:0
|
作者
Shi, Qianwen [1 ,2 ]
Wang, Gege [1 ,2 ]
Wang, Shuhui [1 ,2 ]
Zhang, Chao [1 ,2 ]
Wei, Zhiwen [1 ,2 ]
Guo, Zhongyuan [1 ,2 ]
Zhang, Dan [1 ,2 ]
Yun, Keming [1 ,2 ]
Fu, Shanlin [1 ,2 ,3 ]
机构
[1] Shanxi Med Univ, Sch Forens Med, Taiyuan 030001, Peoples R China
[2] Shanxi Key Lab Forens Med, Shanxi 030600, Peoples R China
[3] Univ Technol Sydney, Ctr Forens Sci, Sydney, NSW 2007, Australia
基金
中国国家自然科学基金;
关键词
Antibiotics; HPLC-MS/MS; Urine; Whole blood; Allergy case; Forensic science; POSTMORTEM FINDINGS; FATAL ANAPHYLAXIS; ASSAY; QUANTIFICATION; ERTAPENEM; DEATHS;
D O I
10.1007/s11419-024-00688-y
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
PurposeA rapid and reliable method was developed and validated for the simultaneous analysis of 52 antibiotics (cephalosporins, penicillins, carbapenems, lincosamides, quinolones, nitroimidazoles, macrolides, sulfonamides, tetracyclines, glycopeptide) in urine and whole blood by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).MethodAnalytes were extracted by dilution or protein precipitation and analyzed on an Agilent 1260 HPLC system coupled to an Agilent 6470 Triple Quadrupole Mass Spectrometer.ResultsThe method attended method validation criteria. The limits of detection were equal or lower than 2.0 ng/mL, whereas the limits of quantification ranged from 0.1 to 10.0 ng/mL, from 0.1 to 5.0 ng/mL, in urine and whole blood, respectively. For all analytes, the bias and intra- and inter-day precision values were less than 14.7%. The ranges of recovery values of all antibiotics were 76.5-124.5% in whole blood and 76.3-121.8% in urine, values of the effects were lower than 25% in two matrices. No evidence of carryover was observed. The study of sample stability showed that almost all analytes were stable at 24 degrees C for 24 h, all analytes were stable at -20 degrees C for 14 days and at -80 degrees C for 30 days. Freeze-thaw cycles stability showed that antibiotics were stable except for imipenem. Autosampler stability study showed that all analytes were stable for 24 h, except for imipenem and amoxicillin. Applicability was proven by analyzing authentic whole blood (n = 86) and urine (n = 79) samples from patients under antibiotics treatment. Therefore, this method was applied to the analysis 3 forensic allergy cases, which were positive for at least one analyte.ConclusionsA simple, sensitive and high-throughput method for the simultaneous determination of different classes of antibiotics in urine and whole blood samples was developed and applied. This sensitive method was successfully applied to forensic cases.
引用
收藏
页码:202 / 211
页数:10
相关论文
共 50 条
  • [31] Liquid chromatography-tandem mass spectrometry method for the determination of thiosulfate in human blood and urine as an indicator of hydrogen sulfide poisoning
    Maseda, Chikatoshi
    Hayakawa, Akira
    Okuda, Katsuhiro
    Asari, Masaru
    Tanaka, Hiroki
    Yamada, Hiromi
    Jin, Shigeki
    Horioka, Kie
    Matoba, Kotaro
    Shiono, Hiroshi
    Matsubara, Kazuo
    Shimizu, Keiko
    LEGAL MEDICINE, 2017, 24 : 67 - 74
  • [32] A targeted ultra performance liquid chromatography - Tandem mass spectrometric assay for tyrosine and metabolites in urine and plasma: Application to the effects of antibiotics on mice
    Letertre, Marine P. M.
    Myridakis, Antonis
    Whiley, Luke
    Camuzeaux, Stephane
    Lewis, Matthew R.
    Chappell, Katie E.
    Thaikkatil, Annie
    Dumas, Marc-Emmanuel
    Nicholson, Jeremy K.
    Swann, Jonathan R.
    Wilson, Ian D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1164
  • [33] Rapid determination of nine barbiturates in human whole blood by liquid chromatography-tandem mass spectrometry
    Zhang, Xinyu
    Lin, Zebin
    Li, Jiaolun
    Huang, Zhibin
    Rao, Yulan
    Liang, Hao
    Yan, Jie
    Zheng, Feng
    DRUG TESTING AND ANALYSIS, 2017, 9 (04) : 588 - 595
  • [34] Optimisation of a liquid chromatography-tandem mass spectrometric method for the determination of acrylamide in foods
    Govaert, Y
    Arisseto, A
    Van Loco, J
    Scheers, E
    Fraselle, S
    Weverbergh, E
    Degroodt, JM
    Goeyens, L
    ANALYTICA CHIMICA ACTA, 2006, 556 (02) : 275 - 280
  • [35] Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: Application to a bioequivalence study
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Choi, Seung-Ki
    Lee, Kyung-Tae
    ANALYTICA CHIMICA ACTA, 2007, 583 (01) : 118 - 123
  • [36] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of pantoprazole sodium in human urine
    Bhaskara, B. L.
    Kumar, U. R. Anil
    Basavaiah, K.
    ARABIAN JOURNAL OF CHEMISTRY, 2011, 4 (02) : 163 - 168
  • [37] Application of a liquid chromatographic/tandem mass spectrometric method to a kinetic study of derivative glucosamine in healthy human urine
    Guan, Yue
    Tian, Yun
    Li, Yan
    Yang, Zhifu
    Jia, Yanyan
    Hang, Taijun
    Wen, Aidong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (01) : 181 - 186
  • [39] Matrix effect-corrected liquid chromatography/tandem mass-spectrometric method for determining acylcarnitines in human urine
    Abe, Kazuki
    Suzuki, Hiroyuki
    Maekawa, Masamitsu
    Shimada, Miki
    Yamaguchi, Hiroaki
    Mano, Nariyasu
    CLINICA CHIMICA ACTA, 2017, 468 : 187 - 194
  • [40] Liquid Chromatography-Tandem Mass Spectrometric Assay for Determination of Stavudine in Human Plasma
    Jin, Fengdan
    JOURNAL OF SPECTROSCOPY, 2014, 2014