Liquid chromatography with tandem mass spectrometric method for determination of 52 antibiotics in human whole blood and urine and application to forensic cases

被引:0
|
作者
Shi, Qianwen [1 ,2 ]
Wang, Gege [1 ,2 ]
Wang, Shuhui [1 ,2 ]
Zhang, Chao [1 ,2 ]
Wei, Zhiwen [1 ,2 ]
Guo, Zhongyuan [1 ,2 ]
Zhang, Dan [1 ,2 ]
Yun, Keming [1 ,2 ]
Fu, Shanlin [1 ,2 ,3 ]
机构
[1] Shanxi Med Univ, Sch Forens Med, Taiyuan 030001, Peoples R China
[2] Shanxi Key Lab Forens Med, Shanxi 030600, Peoples R China
[3] Univ Technol Sydney, Ctr Forens Sci, Sydney, NSW 2007, Australia
基金
中国国家自然科学基金;
关键词
Antibiotics; HPLC-MS/MS; Urine; Whole blood; Allergy case; Forensic science; POSTMORTEM FINDINGS; FATAL ANAPHYLAXIS; ASSAY; QUANTIFICATION; ERTAPENEM; DEATHS;
D O I
10.1007/s11419-024-00688-y
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
PurposeA rapid and reliable method was developed and validated for the simultaneous analysis of 52 antibiotics (cephalosporins, penicillins, carbapenems, lincosamides, quinolones, nitroimidazoles, macrolides, sulfonamides, tetracyclines, glycopeptide) in urine and whole blood by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).MethodAnalytes were extracted by dilution or protein precipitation and analyzed on an Agilent 1260 HPLC system coupled to an Agilent 6470 Triple Quadrupole Mass Spectrometer.ResultsThe method attended method validation criteria. The limits of detection were equal or lower than 2.0 ng/mL, whereas the limits of quantification ranged from 0.1 to 10.0 ng/mL, from 0.1 to 5.0 ng/mL, in urine and whole blood, respectively. For all analytes, the bias and intra- and inter-day precision values were less than 14.7%. The ranges of recovery values of all antibiotics were 76.5-124.5% in whole blood and 76.3-121.8% in urine, values of the effects were lower than 25% in two matrices. No evidence of carryover was observed. The study of sample stability showed that almost all analytes were stable at 24 degrees C for 24 h, all analytes were stable at -20 degrees C for 14 days and at -80 degrees C for 30 days. Freeze-thaw cycles stability showed that antibiotics were stable except for imipenem. Autosampler stability study showed that all analytes were stable for 24 h, except for imipenem and amoxicillin. Applicability was proven by analyzing authentic whole blood (n = 86) and urine (n = 79) samples from patients under antibiotics treatment. Therefore, this method was applied to the analysis 3 forensic allergy cases, which were positive for at least one analyte.ConclusionsA simple, sensitive and high-throughput method for the simultaneous determination of different classes of antibiotics in urine and whole blood samples was developed and applied. This sensitive method was successfully applied to forensic cases.
引用
收藏
页码:202 / 211
页数:10
相关论文
共 50 条
  • [21] Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Olanzapine in Human Urine
    Urdigere, Anil Kumar Rangachar
    Besagarahally, Bhasakra Laxmaiah
    Basavaiah, Kanakapura
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (05) : 1381 - 1387
  • [22] Development of a high-performance liquid chromatography-tandem mass spectrometric method for the determination of Methimazole in human blood matrices
    Ito, Yusuke
    Sakai, Hiroyuki
    Nagao, Hidenori
    Suzuki, Ryota
    Odawara, Masato
    Minato, Kouichi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1144
  • [23] Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of α-methyltyrosine in human plasma
    Humphries, D
    Ruterbories, K
    Chan, C
    Narayanan, R
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02): : 229 - 234
  • [24] A specific method for the measurement of tacrolimus in human whole blood by liquid chromatography tandem mass spectrometry
    Zhang, QL
    Simpson, J
    Aboleneen, HI
    THERAPEUTIC DRUG MONITORING, 1997, 19 (04) : 470 - 476
  • [25] A specific method for the measurement of cyclosporin A in human whole blood by liquid chromatography tandem mass spectrometry
    Simpson, J
    Zhang, QL
    Ozaeta, P
    Aboleneen, H
    THERAPEUTIC DRUG MONITORING, 1998, 20 (03) : 294 - 300
  • [26] Determination of a novel thrombin inhibitor in human plasma and urine utilizing Liquid chromatography with tandem mass spectrometric and ultraviolet detection
    Song, HC
    Gu, XM
    Riffel, K
    Yan, K
    Lo, MW
    JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (01): : 83 - 91
  • [27] Liquid chromatography tandem mass spectrometry for the determination of nine insecticides and fungicides in human postmortem blood and urine
    Mouskeftara, Thomai
    Virgiliou, Christina
    Iakovakis, Achilleas
    Raikos, Nikolaos
    Gika, Helen G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1179
  • [28] One-step sample processing method for the determination of perchlorate in human urine, whole blood and breast milk using liquid chromatography tandem mass spectrometry
    Song, Shiming
    Ruan, Jujun
    Bai, Xueyuan
    Xie, Lei
    Zhang, Bo
    He, Yuan
    Zhang, Tao
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2019, 174 : 175 - 180
  • [29] Liquid chromatography-tandem mass spectrometry assay to quantify plitidepsin in human plasma, whole blood and urine
    van Andel, L.
    Rosing, H.
    Fudio, S.
    Aviles, P.
    Tibben, M. M.
    Gebretensae, A.
    Schellens, J. H. M.
    Beijnen, J. H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 137 - 143
  • [30] A Liquid ChromatographyElectrospray Tandem Mass Spectrometry Method for the Determination of Antiarrhythmic Drugs and Their Metabolites in Forensic Whole Blood Samples
    Sorensen, Lambert K.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (02) : 116 - 122