Dual threshold input receiver FPGA-only signal digitization method for time-of-flight positron emission tomography

被引:3
|
作者
Ko, Guen Bae [1 ,2 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ]
机构
[1] Brightonix Imaging Inc, Seoul 04782, South Korea
[2] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 03080, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul 03080, South Korea
[4] Seoul Natl Univ, Coll Engn, Interdisciplinary Program Bioengn, Seoul 03080, South Korea
关键词
Positron emission tomography; Field-programmable gate array; Silicon photomultiplier; Time-to-digital converter; Time-over-threshold; PET; PET/MRI;
D O I
10.1007/s13534-024-00380-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As silicon photomultiplier (SiPM)-based time-of-flight (TOF) positron emission tomography (PET) becomes popular, the need for sophisticated PET data acquisition (DAQ) systems is increasing. One promising solution to this challenge is the adoption of a field-programmable gate array (FPGA)-only signal digitization method. In this paper, we propose a new approach to efficiently implement an FPGA-only digitizer. We configured the input/output (IO) port of the FPGA to function as a dual-threshold voltage comparator through the use of simple passive circuitry and heterogeneous IO standards. This configuration overcomes the limitations of existing methods by allowing different threshold voltages for adjacent IO pins, effectively reducing routing complexity and lowering manufacturing costs. An FPGA-only digitizer was implemented by integrating the dual-threshold voltage comparator and FPGA-based time-to-digital converter. By combining the dual-threshold time-over-threshold (TOT) method and curve fitting, precise energy information could be obtained. The performance of the FPGA-only digitizer was assessed using a detector setup comprising a 3 x 3 x 20 mm3 LYSO scintillation crystal and a single pixel SiPM. Using the configured evaluation setup, an energy resolution of 12.5% and a time resolution of 146 +/- 9 ps were achieved for a 20 mm scintillation crystal. The dual-threshold TOT implemented using the proposed method showed consistent linearity across an energy range of 100 keV to 600 keV. The proposed method is well-suited for the development of cost-effective DAQ systems in highly integrated TOF PET systems.
引用
收藏
页码:847 / 858
页数:12
相关论文
共 50 条
  • [41] EndoTOFPET-US - A Miniaturised Calorimeter for Endoscopic Time-of-Flight Positron Emission Tomography
    Zvolsky, Milan
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [42] Analytic time-of-flight positron emission tomography reconstruction: two-dimensional case
    Gengsheng L. Zeng
    Ya Li
    Qiu Huang
    Visual Computing for Industry, Biomedicine, and Art, 2
  • [43] Iterative Simultaneous Attenuation Correction and Activity Estimation for Time-of-Flight Positron Emission Tomography
    Nam-Yong Lee
    You Suk Kim
    Hyun Keong Lim
    Yong Choi
    Journal of the Korean Physical Society, 2020, 77 : 689 - 699
  • [44] Analytic time-of-flight positron emission tomography reconstruction: two-dimensional case
    Zeng, Gengsheng L.
    Li, Ya
    Huang, Qiu
    VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2019, 2 (01)
  • [45] Development and Initial Results of a Brain PET Insert for Simultaneous 7-Tesla PET/MRI Using an FPGA-Only Signal Digitization Method
    Won, Jun Yeon
    Park, Haewook
    Lee, Seungeun
    Son, Jeong-Whan
    Chung, Yina
    Ko, Guen Bae
    Kim, Kyeong Yun
    Song, Junghyun
    Seo, Seongho
    Ryu, Yeunchul
    Chung, Jun-Young
    Lee, Jae Sung
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (06) : 1579 - 1590
  • [46] The effects of object size, attenuation, scatter, and random coincidences on signal to noise ratio in simulations of time-of-flight positron emission tomography
    Harrison, Robert L.
    Gillispie, Steven B.
    Alessio, Adam M.
    Kinahan, Paul E.
    Lewellen, Thomas K.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1900 - 1904
  • [47] Time-of-Flight Positron Emission Tomography with Resistive Plate Chamber Detectors: An Unlikely but Promising Approach
    Couceiro, M.
    Crespo, P.
    Blanco, A.
    Ferreira, N. C.
    Mendes, L.
    Ferreira Marques, R.
    Fonte, P.
    ACTA PHYSICA POLONICA A, 2015, 127 (05) : 1453 - 1461
  • [48] Assessment of a high-resolution candidate detector for prostate time-of-flight positron emission tomography
    Cosentino, Luigi
    Finocchiaro, Paolo
    Pappalardo, Alfio
    Garibaldi, Franco
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (11):
  • [49] A MATHEMATICAL-MODEL FOR POSITRON-EMISSION TOMOGRAPHY SYSTEMS HAVING TIME-OF-FLIGHT MEASUREMENTS
    SNYDER, DL
    THOMAS, LJ
    TERPOGOSSIAN, MM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 3575 - 3583
  • [50] A Statistical Reconstruction Algorithm for Positronium Lifetime Imaging Using Time-of-Flight Positron Emission Tomography
    Huang, Hsin-Hsiung
    Zhu, Zheyuan
    Booppasiri, Slun
    Chen, Zhuo
    Pang, Shuo
    Kao, Chien-Min
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2025, 9 (04) : 478 - 486