Application of transfer learning for rapid calibration of spatially resolved diffuse reflectance probes for extraction of tissue optical properties

被引:1
|
作者
Hannan, Md Nafiz [1 ]
Baran, Timothy M. [2 ,3 ,4 ]
机构
[1] Univ Rochester, Dept Phys & Astron, Rochester, NY USA
[2] Univ Rochester, Dept Imaging Sci, Med Ctr, Rochester, NY 14642 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
[4] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
基金
美国国家卫生研究院;
关键词
diffuse reflectance spectroscopy; machine learning; neural network; transfer learning; Monte Carlo simulation; NONINVASIVE DETERMINATION; PHOTODYNAMIC THERAPY; NEURAL-NETWORK; SCATTERING; MODEL;
D O I
10.1117/1.JBO.29.2.027004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
<bold>Significance: </bold>Treatment planning for light-based therapies including photodynamic therapy requires tissue optical property knowledge. These are recoverable with spatially-resolved diffuse reflectance spectroscopy (DRS), but requires precise source-detector separation (SDS) determination and time-consuming simulations. <bold>Aim: </bold>An artificial neural network (ANN) to map from DRS at short SDS to optical properties was created. This trained ANN was adapted to fiber-optic probes with varying SDS using transfer learning. <bold>Approach: </bold>An ANN mapping from measurements to Monte Carlo simulation to optical properties was created with one fiber-optic probe. A second probe with different SDS was used for transfer learning algorithm creation. Data from a third were used to test this algorithm. <bold>Results: </bold>The initial ANN recovered absorber concentration with RMSE=0.29 mu M (7.5% mean error) and mu (s) (') at 665 nm (mu (s,665) (') ) with RMSE=0.77 cm (-1) (2.5% mean error). For probe-2, transfer learning significantly improved absorber concentration (0.38 vs. 1.67 mu M, p=0.0005) and mu (s,665) (') (0.71 vs. 1.8 cm (-1) , p=0.0005) recovery. A third probe also showed improved absorber (0.7 vs. 4.1 mu M, p<0.0001) and <mu> (s,665) (') (1.68 vs. 2.08 cm (-1) , p=0.2) recovery. <bold>Conclusions: </bold>A data-driven approach to optical property extraction can be used to rapidly calibrate new fiber-optic probes with varying SDS, with as few as three calibration spectra.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Optimization of inverse algorithm for estimating the optical properties of biological materials using spatially-resolved diffuse reflectance
    Cen, Haiyan
    Lu, Renfu
    Dolan, Kirk
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2010, 18 (06) : 853 - 872
  • [32] Metamodeling approach for efficient estimation of optical properties of turbid media from spatially resolved diffuse reflectance measurements
    Watte, Rodrigo
    Nghia Nguyen Do Trong
    Aernouts, Ben
    Erkinbaev, Chyngyz
    De Baerdemaeker, Josse
    Nicolai, Bart
    Saeys, Wouter
    OPTICS EXPRESS, 2013, 21 (26): : 32630 - 32642
  • [33] Influence of layered tissue architecture on estimates of tissue optical properties obtained from spatially resolved diffuse reflectometry
    Farrell, TJ
    Patterson, MS
    Essenpreis, M
    APPLIED OPTICS, 1998, 37 (10): : 1958 - 1972
  • [34] Sensitivity of spatially-resolved diffuse reflectance to optical parameters in the hybrid diffusion approximation
    Tian Hui-Juan
    Niu Ping-Juan
    ACTA PHYSICA SINICA, 2012, 61 (18)
  • [35] Sensitivity of spatially-resolved diffuse reflectance to high-order optical parameters
    Liu Ying
    Wang Li-Jun
    Guo Yun-Feng
    Zhang Xiao-Juan
    Gao Zong-Hui
    Tian Hui-Juan
    ACTA PHYSICA SINICA, 2007, 56 (04) : 2119 - 2123
  • [36] Determination of the optical properties of turbid media by measurement of the spatially resolved reflectance
    Pilz, Marco
    Kienle, Alwin
    DIFFUSE OPTICAL IMAGING OF TISSUE, 2007, 6629
  • [37] Estimation of optical properties by spatially resolved reflectance spectroscopy in the subdiffusive regime
    Naglic, Peter
    Pernus, Franjo
    Likar, Bostjan
    Burmen, Miran
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (09)
  • [38] Comparison of spatially and temporally resolved diffuse transillumination measurement systems for extraction of optical properties of scattering media
    Ortiz-Rascon, E.
    Bruce, N. C.
    Garduno-Mejia, J.
    Carrillo-Torres, R.
    Hernandez-Paredes, J.
    Alvarez-Ramos, M. E.
    APPLIED OPTICS, 2017, 56 (33) : 9199 - 9204
  • [39] Accurate extraction of optical properties and top layer thickness of two-layered mucosal tissue phantoms from spatially resolved reflectance spectra
    Sung, Kung-Bin
    Shih, Kuang-Wei
    Hsu, Fang-Wei
    Hsieh, Hong-Po
    Chuang, Min-Jie
    Hsiao, Yi-Hsien
    Su, Yu-Hui
    Tien, Gen-Hao
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)
  • [40] Estimation of optical properties of turbid media using spatially resolved diffuse reflectance combined with LSTM-attention network
    Sun, Danni
    Wang, Xin
    Huang, Min
    Zhu, Qibing
    Qin, Jianwei
    OPTICS EXPRESS, 2023, 31 (06) : 10260 - 10272