Dosimetric verification on HIMM at the Wuwei heavy ion therapy center using anthropomorphic phantoms

被引:0
|
作者
Li, Peng [1 ,2 ,3 ]
Fei, Xiu-Lan [4 ]
He, Peng-Bo [5 ]
Shen, Xiao [6 ]
Li, Qiang [5 ]
Chen, Ying-Yao [1 ,2 ]
机构
[1] Fudan Univ, Sch Publ Hlth, Shanghai 200030, Peoples R China
[2] Fudan Univ, Key Lab Hlth Technol Assessment, Natl Hlth Commiss, Shanghai 200030, Peoples R China
[3] Wuwei Tumour Hosp Gansu Prov, Wuwei 733000, Peoples R China
[4] Gansu Prov Ctr Dis Control & Prevent, Lanzhou 730030, Peoples R China
[5] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730030, Peoples R China
[6] Lanzhou Univ, Dept Gastroenterol, Hosp 1, Lanzhou 730030, Peoples R China
关键词
Carbon-ion radiotherapy; HIMM; Dosimetric verification; Respiratory gating; Carbon ion plan (ciPlan); IRRADIATION;
D O I
10.1016/j.radphyschem.2024.111644
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Heavy Ion Medical Machine (HIMM) at Wuwei Heavy Ion Therapy Center has been officially approved. The aim of this study was to demonstrate the dosimetric stability and safety of HIMM prior to subsequent clinical trials. Dosimetric verification of treatment plans was conducted using anthropomorphic phantoms in a uniformly scanned beam delivery mode. Both head-and-neck and thoracoabdominal regions of anthropomorphic phantoms dedicatedly inserted with a Farmer-type ionization chamber were scanned under a 64-slice CT scanner. Planning target volumes (PTV) were delineated according to the two sets of acquired CT images. The sensitive volume of the chamber was located in the center, rising edge, plateau and falling edge of PTV, respectively. Then treatment plans were designed for the target volumes using a carbon-ion radiotherapy planning system. Dose measurements were conducted following the IAEA guidelines. Virtual respiratory signals were generated to simulate respiratory conditions, and gating irradiation was conducted on the thoracoabdominal phantom. Dose measurements were performed three times at each point. For the dosimetric verification of both the head-and-neck and thoracoabdominal phantoms, the deviations between planned and measured doses were confirmed to be within acceptable limits. For respiratory gating irradiation, the deviation was 0.32% in the center of PTV. The irradiation time was increased approximately twofold as compared to the non-gated situation. Intraclass correlation coefficient (ICC) value of the measured dose was 1.000. The results met the requirements. The passive beam delivery mode of HIMM demonstrated satisfactory dosimetric performance, making it suitable for the upcoming clinical trials.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] In Vivo Dosimetric Verification of Volumetric Modulated Arc Therapy for Prostate Cancer using a Rectal Balloon
    Fontenot, J. D.
    Price, M.
    King, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S819 - S819
  • [22] Dosimetric Effects of Tissue Heterogeneity in Proton Therapy: Monte Carlo Simulation and Experimental Study Using Animal Tissue Phantoms
    Liu, Y.
    Zheng, Y.
    MEDICAL PHYSICS, 2012, 39 (06) : 3815 - 3816
  • [23] Dosimetric verification of gated delivery of electron beams using a 2D ion chamber array
    Yoganathan, S. A.
    Das, K. J. Maria
    Raj, D. Gowtham
    Kumar, Shaleen
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (02) : 68 - 73
  • [24] Incorporating Prostate Interfractional Motion Into Gunma Heavy Ion Medical Center Carbon Ion Radiation Therapy
    Bridges, D.
    Fukata, K.
    Kanai, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 3169 - 3170
  • [25] Commissioning of carbon-ion radiotherapy for moving targets at the Osaka Heavy-Ion Therapy Center
    Hamatani, Noriaki
    Tsubouchi, Toshiro
    Takashina, Masaaki
    Yagi, Masashi
    Kanai, Tatsuaki
    MEDICAL PHYSICS, 2022, 49 (02) : 801 - 812
  • [26] Dosimetric validation of intensity-modulated bolus electron conformal therapy planning and delivery using an anthropomorphic cylindrical head phantom
    McGuffey, Andrew S.
    Pitcher, Garrett M.
    Erhart, Kevin J.
    Hogstrom, Kenneth R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [27] Dosimetric characteristics of a virtual wedge system measured by ion chamber, therapy verification X-films and radiochromic films
    Negi, PS
    Munjal, RK
    Sinha, SN
    Hukku, S
    Kataria, T
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2544 - 2546
  • [28] Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms
    Jung, Jinhong
    Song, Si Yeol
    Min, Sang
    Yoon, KyoungJun
    Choi, Wonsik
    Jeong, Seong-Yun
    Choi, Eun Kyung
    Cho, Byungchul
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (04): : 745 - 753
  • [29] DOSIMETRIC VERIFICATION OF VOLUMETRIC MODULATED ARC THERAPY (RAPIDARC) FOR HEAD AND NECK USING GAFCHROMIC EBT FILM
    Sjolin, M.
    Sjostrom, D.
    Behrens, C. F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S455 - S455
  • [30] Particle Radiation Therapy of Head and Neck Malignancies at the Shanghai Proton and Heavy Ion Center
    Kong, L.
    Hu, J.
    Gao, J.
    Guan, X.
    Hu, W.
    Yang, J.
    Bao, C.
    Dong, Y.
    Huang, Y.
    Lu, J. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (05): : 1403 - 1403