Dosimetric verification on HIMM at the Wuwei heavy ion therapy center using anthropomorphic phantoms

被引:0
|
作者
Li, Peng [1 ,2 ,3 ]
Fei, Xiu-Lan [4 ]
He, Peng-Bo [5 ]
Shen, Xiao [6 ]
Li, Qiang [5 ]
Chen, Ying-Yao [1 ,2 ]
机构
[1] Fudan Univ, Sch Publ Hlth, Shanghai 200030, Peoples R China
[2] Fudan Univ, Key Lab Hlth Technol Assessment, Natl Hlth Commiss, Shanghai 200030, Peoples R China
[3] Wuwei Tumour Hosp Gansu Prov, Wuwei 733000, Peoples R China
[4] Gansu Prov Ctr Dis Control & Prevent, Lanzhou 730030, Peoples R China
[5] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730030, Peoples R China
[6] Lanzhou Univ, Dept Gastroenterol, Hosp 1, Lanzhou 730030, Peoples R China
关键词
Carbon-ion radiotherapy; HIMM; Dosimetric verification; Respiratory gating; Carbon ion plan (ciPlan); IRRADIATION;
D O I
10.1016/j.radphyschem.2024.111644
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Heavy Ion Medical Machine (HIMM) at Wuwei Heavy Ion Therapy Center has been officially approved. The aim of this study was to demonstrate the dosimetric stability and safety of HIMM prior to subsequent clinical trials. Dosimetric verification of treatment plans was conducted using anthropomorphic phantoms in a uniformly scanned beam delivery mode. Both head-and-neck and thoracoabdominal regions of anthropomorphic phantoms dedicatedly inserted with a Farmer-type ionization chamber were scanned under a 64-slice CT scanner. Planning target volumes (PTV) were delineated according to the two sets of acquired CT images. The sensitive volume of the chamber was located in the center, rising edge, plateau and falling edge of PTV, respectively. Then treatment plans were designed for the target volumes using a carbon-ion radiotherapy planning system. Dose measurements were conducted following the IAEA guidelines. Virtual respiratory signals were generated to simulate respiratory conditions, and gating irradiation was conducted on the thoracoabdominal phantom. Dose measurements were performed three times at each point. For the dosimetric verification of both the head-and-neck and thoracoabdominal phantoms, the deviations between planned and measured doses were confirmed to be within acceptable limits. For respiratory gating irradiation, the deviation was 0.32% in the center of PTV. The irradiation time was increased approximately twofold as compared to the non-gated situation. Intraclass correlation coefficient (ICC) value of the measured dose was 1.000. The results met the requirements. The passive beam delivery mode of HIMM demonstrated satisfactory dosimetric performance, making it suitable for the upcoming clinical trials.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] External breast radiotherapy treatment planning verification using advanced anthropomorphic phantoms
    Santos, J. A. M.
    Lencart, J.
    Dias, A. G.
    Cunha, L. T.
    Relvas, C.
    Ramos, A.
    Neto, V. F.
    TECHNOLOGY AND MEDICAL SCIENCES - TMSI 2010, 2011, : 341 - 344
  • [2] Range verification in heavy-ion therapy using a hadron tumour marker
    Kasanda, E.
    Bildstein, V
    Hymers, D.
    Easter, J.
    Richard, A. L.
    Baumann, T.
    Spyrou, A.
    Hoehr, C.
    Muecher, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (19):
  • [3] Validation of dose planning calculations for boron neutron capture therapy using cylindrical and anthropomorphic phantoms
    Koivunoro, Hanna
    Seppala, Tiina
    Uusi-Simola, Jouni
    Merimaa, Katja
    Kotiluoto, Petri
    Seren, Tom
    Kortesniemi, Mika
    Auterinen, Iiro
    Savolainen, Sauli
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3515 - 3533
  • [4] Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center
    Tessonnier, T.
    Boehlen, T. T.
    Ceruti, F.
    Ferrari, A.
    Sala, P.
    Brons, S.
    Haberer, T.
    Debus, J.
    Parodi, K.
    Mairani, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16): : 6579 - 6594
  • [5] Assessment of the induced radioactivity in the treatment room of the heavy-ion medical machine in Wuwei using PHITS
    Ying Luo
    Sheng-Cong Huang
    Hui Zhang
    Hai-Jun Mao
    Qiang Li
    Zhong-Ying Dai
    NuclearScienceandTechniques, 2023, 34 (02) : 155 - 168
  • [6] Dosimetric verification of cancer patient?s treatment plan using an anthropomorphic, 3D-printed phantom
    Waluk, Kacper
    Pietrzak, Jakub
    APPLIED RADIATION AND ISOTOPES, 2023, 191
  • [7] Alignment of heavy ion therapy center vertical terminal
    Chen, Wenjun
    Yang, Yaqing
    Cai, Guozhu
    Zheng, Yajun
    Wang, Shaoming
    Yuan, Jiandong
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2019, 174 (9-10): : 809 - 818
  • [8] Variability of surface and center position radiation dose in MDCT: Monte Carlo simulations using CTDI and anthropomorphic phantoms
    Zhang, Di
    Savandi, Ali S.
    Demarco, John J.
    Cagnon, Chris H.
    Angel, Erin
    Turner, Adam C.
    Cody, Dianna D.
    Stevens, Donna M.
    Primak, Andrew N.
    McCollough, Cynthia H.
    McNitt-Gray, Michael F.
    MEDICAL PHYSICS, 2009, 36 (03) : 1025 - 1038
  • [9] Assessment of the induced radioactivity in the treatment room of the heavy-ion medical machine in Wuwei using PHITS
    Ying Luo
    Sheng-Cong Huang
    Hui Zhang
    Hai-Jun Mao
    Qiang Li
    Zhong-Ying Dai
    Nuclear Science and Techniques, 2023, 34
  • [10] Assessment of the induced radioactivity in the treatment room of the heavy-ion medical machine in Wuwei using PHITS
    Luo, Ying
    Huang, Sheng-Cong
    Zhang, Hui
    Mao, Hai-Jun
    Li, Qiang
    Dai, Zhong-Ying
    NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (02)