Range verification in heavy-ion therapy using a hadron tumour marker

被引:0
|
作者
Kasanda, E. [1 ,2 ]
Bildstein, V [1 ]
Hymers, D. [1 ,3 ]
Easter, J. [1 ]
Richard, A. L. [4 ,5 ,8 ]
Baumann, T. [4 ]
Spyrou, A. [4 ,5 ]
Hoehr, C. [6 ,7 ]
Muecher, D. [1 ,3 ,6 ]
机构
[1] Univ Guelph, Dept Phys, 50 Stone Rd E, Guelph, ON N1G 2W1, Canada
[2] Univ Bern, Lab High Energy Phys, Sidlerstr 5, CH-3012 Bern, Switzerland
[3] Univ Cologne, Inst Kernphys, Zulpicher Str 77, D-50937 Cologne, Germany
[4] Michigan State Univ, Facil Rare Isotope Beams, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Phys & Astron, E Lansing, MI 48824 USA
[6] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[7] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
[8] Lawrence Livermore Natl Lab, Livermore, CA USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 19期
基金
加拿大自然科学与工程研究理事会;
关键词
hadron therapy; range verification; tumour marker; spectroscopy; PROTON; RADIOTHERAPY; FACILITY;
D O I
10.1088/1361-6560/acf557
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Anew method to estimate the range of an ion beam in a patient during heavy-ion therapy was investigated, which was previously verified for application in proton therapy. Approach. The method consists of placing a hadron tumour marker (HTM) close to the tumour. As the treatment beam impinges on the HTM, the marker undergoes nuclear reactions. When theHTMmaterial is carefully chosen, the activation results in the emission of several delayed, characteristic gamma rays, whose intensities are correlated with the remaining range inside the patient. When not just one but two reaction channels are investigated, the ratio between these two gamma ray emissions can be measured, and the ratio is independent of any beam delivery uncertainties. Main results. A proof-of-principle experiment with an 16Oion beam and Ag foils asHTMwas successfully executed. The Ag-107(O-16, (x))Sb-112 and the Ag-107(O-16, x)(114) Sb reaction channels were identified as suitable for theHTM technique. When only one gamma-ray emission is measured, the resulting range-uncertainty estimation is at the 0.5mmscale. When both channels are considered, a theoretical limit on the range uncertainty of a clinical fiducal marker was found to be +/- 290 mu m. Significance. Range uncertainty of a heavy-ion beam limits the prescribed treatment plan for cancer patients, especially the direction of the ion beam in relation to any organ at risk. An easy to implement range-verification technique which can be utilized during clinical treatment would allow treatment plans to take full advantage of the sharp falloff of the Bragg peak without the risk of depositing excessive dose into healthy tissue.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Range Verification in Heavy-Ion Therapy with a Hadron Tumour Marker (HTM)
    Kasanda, E.
    Easter, J.
    Hymers, D.
    Burbadge, C.
    Bildstein, V.
    Spyrou, A.
    Hoehr, C.
    Muecher, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E840 - E841
  • [2] Submillimeter Range Verification in Proton Therapy with a Hadron Tumour Marker (HTM)
    Burbadge, C.
    Kasanda, E.
    Bildstein, V.
    Behnamian, H.
    Belanger-Champagne, C.
    Hoehr, C.
    Muecher, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E344 - E344
  • [3] Positron camera for range verification of heavy-ion radiotherapy
    Iseki, Y
    Mizuno, H
    Futami, Y
    Tomitani, T
    Kanai, T
    Kanazawa, M
    Kitagawa, A
    Murakami, T
    Nishio, T
    Suda, M
    Urakabe, E
    Yunoki, A
    Sakai, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (03): : 840 - 849
  • [4] Improved sub-milimeter range-verification method for proton therapy using a composite hadron tumour marker (HTM)
    Kasanda, E.
    Burbadge, C.
    Bildstein, V
    Belanger-Champagne, C.
    Behnamian, H.
    Hoehr, C.
    Muecher, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (18):
  • [5] Range verification system using positron emitting beams for heavy-ion radiotherapy
    Iseki, Y
    Kanai, T
    Kanazawa, M
    Kitagawa, A
    Mizuno, H
    Tomitani, T
    Suda, M
    Urakabe, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3179 - 3195
  • [6] On the Ion Beam Range and Dose Verification in Hadron Therapy Using Sound Waves
    Fourkal, E.
    Veltchev, I.
    Gayou, O.
    Nahirnyak, V.
    MEDICAL PHYSICS, 2015, 42 (06) : 3296 - 3296
  • [7] HADRON CHEMISTRY IN HEAVY-ION COLLISIONS
    MONTVAY, I
    ZIMANYI, J
    NUCLEAR PHYSICS A, 1979, 316 (03) : 490 - 508
  • [8] A method for in-vivo treatment plan verification of heavy-ion tumour therapy by positron emission tomography
    Hinz, R
    Byars, L
    Enghardt, W
    Hasch, BG
    Lauckner, K
    Pawelke, J
    Sobiella, M
    PHYSICA MEDICA, 1997, 13 : 61 - 63
  • [9] HADRON DISTRIBUTIONS AT CERN - HEAVY-ION EXPERIMENTS
    JACAK, B
    NUCLEAR EQUATION OF STATE, PT B: QCD AND THE FORMATION OF THE QUARK-GLUON PLASMA, 1989, 216 : 125 - 136
  • [10] Production of hadron resonances in heavy-ion collisions
    I. I. Royzen
    Physics of Atomic Nuclei, 2005, 68 : 2117 - 2123