Range verification in heavy-ion therapy using a hadron tumour marker

被引:0
|
作者
Kasanda, E. [1 ,2 ]
Bildstein, V [1 ]
Hymers, D. [1 ,3 ]
Easter, J. [1 ]
Richard, A. L. [4 ,5 ,8 ]
Baumann, T. [4 ]
Spyrou, A. [4 ,5 ]
Hoehr, C. [6 ,7 ]
Muecher, D. [1 ,3 ,6 ]
机构
[1] Univ Guelph, Dept Phys, 50 Stone Rd E, Guelph, ON N1G 2W1, Canada
[2] Univ Bern, Lab High Energy Phys, Sidlerstr 5, CH-3012 Bern, Switzerland
[3] Univ Cologne, Inst Kernphys, Zulpicher Str 77, D-50937 Cologne, Germany
[4] Michigan State Univ, Facil Rare Isotope Beams, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Phys & Astron, E Lansing, MI 48824 USA
[6] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[7] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
[8] Lawrence Livermore Natl Lab, Livermore, CA USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 19期
基金
加拿大自然科学与工程研究理事会;
关键词
hadron therapy; range verification; tumour marker; spectroscopy; PROTON; RADIOTHERAPY; FACILITY;
D O I
10.1088/1361-6560/acf557
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Anew method to estimate the range of an ion beam in a patient during heavy-ion therapy was investigated, which was previously verified for application in proton therapy. Approach. The method consists of placing a hadron tumour marker (HTM) close to the tumour. As the treatment beam impinges on the HTM, the marker undergoes nuclear reactions. When theHTMmaterial is carefully chosen, the activation results in the emission of several delayed, characteristic gamma rays, whose intensities are correlated with the remaining range inside the patient. When not just one but two reaction channels are investigated, the ratio between these two gamma ray emissions can be measured, and the ratio is independent of any beam delivery uncertainties. Main results. A proof-of-principle experiment with an 16Oion beam and Ag foils asHTMwas successfully executed. The Ag-107(O-16, (x))Sb-112 and the Ag-107(O-16, x)(114) Sb reaction channels were identified as suitable for theHTM technique. When only one gamma-ray emission is measured, the resulting range-uncertainty estimation is at the 0.5mmscale. When both channels are considered, a theoretical limit on the range uncertainty of a clinical fiducal marker was found to be +/- 290 mu m. Significance. Range uncertainty of a heavy-ion beam limits the prescribed treatment plan for cancer patients, especially the direction of the ion beam in relation to any organ at risk. An easy to implement range-verification technique which can be utilized during clinical treatment would allow treatment plans to take full advantage of the sharp falloff of the Bragg peak without the risk of depositing excessive dose into healthy tissue.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Hadronization and Charm-Hadron Ratios in Heavy-Ion Collisions
    He, Min
    Rapp, Ralf
    PHYSICAL REVIEW LETTERS, 2020, 124 (04)
  • [42] Opportunities for heavy-ion physics at the large hadron collider LHC
    Wiedemann, Urs Achim
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2007, 34 (08) : S503 - S509
  • [43] Charged Hadron Multiplicity Distribution at Relativistic Heavy-Ion Colliders
    Kumar, Ashwini
    Srivastava, P. K.
    Singh, B. K.
    Singh, C. P.
    ADVANCES IN HIGH ENERGY PHYSICS, 2013, 2013
  • [44] SIMILARITY OF HADRON-PRODUCTION IN PP AND HEAVY-ION COLLISIONS
    HOANG, TF
    ZEITSCHRIFT FUR PHYSIK C-PARTICLES AND FIELDS, 1994, 61 (02): : 341 - 345
  • [45] RANGE PARAMETER DISTORTION IN HEAVY-ION IMPLANTATION
    BLANK, P
    WITTMAACK, K
    PHYSICS LETTERS A, 1975, 54 (01) : 33 - 34
  • [46] WEIGHING THE BENEFITS OF HEAVY-ION THERAPY
    NATHAN, R
    NATURE MEDICINE, 1995, 1 (07) : 606 - 607
  • [47] THE HEAVY-ION THERAPY PROJECT AT GSI
    KRAFT, G
    BECHER, W
    BLASCHE, K
    BOHNE, D
    FISCHER, B
    GADEMANN, G
    GEISSEL, H
    HABERER, T
    KLABUNDE, J
    KRAFTWEYRATHER, W
    LANGENBECK, B
    MUNZENBERG, G
    RITTER, S
    ROSCH, W
    SCHARDT, D
    STELZER, H
    SCHWAB, T
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 911 - 914
  • [48] Progresses of heavy-ion cancer therapy
    Xiao Guo-Qing
    Zhang Hong
    Li Qiang
    Song Ming-Tao
    Yuan You-Jin
    Xia Jia-Wen
    Zhan Wen-Long
    CHINESE PHYSICS C, 2008, 32 : 8 - 12
  • [49] Therapy planning for heavy-ion irradiation
    Kramer, M
    Jakel, O
    ADVANCES IN HADRONTHERAPY, 1997, 1144 : 351 - 358
  • [50] Proton therapy range verification method via delayed γ-ray spectroscopy of a molybdenum tumour marker
    Burbadge, C.
    Kasanda, E.
    Bildstein, V
    Dublin, G.
    Olaizola, B.
    Hohr, C.
    Mucher, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (02):