INFLUENCE OF CAPILLARY DIMENSIONS ON THE PERFORMANCE OF A COAXIAL CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY INTERFACE

被引:23
|
作者
TETLER, LW [1 ]
COOPER, PA [1 ]
POWELL, B [1 ]
机构
[1] ZENECA SPECIALTIES,MANCHESTER M9 3DA,LANCS,ENGLAND
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/0021-9673(94)01171-A
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The dimensions of the capillaries used to construct a typical coaxial capillary electrophoresis-mass spectrometry (CE-MS) interface, i.e. the inner diameter, the outer diameter and the wall thickness, have been shown to affect the performance of the CE-MS system. The influence of these parameters has been investigated in both MS and MS-MS modes. The initial results indicate that by reducing all the sheath capillaries' dimensions and the CE capillary outer diameter, better operation and increased sensitivity can be achieved. The capillary arrangement which gives optimum sensitivity and stable operation has been suggested.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [41] Development of a multiplexed interface for capillary electrophoresis-electrospray ion trap mass spectrometry
    Li, Fu-An
    Wu, Ming-Chi
    Her, Guor-Rong
    ANALYTICAL CHEMISTRY, 2006, 78 (15) : 5316 - 5321
  • [42] CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY USING A COAXIAL CONTINUOUS-FLOW FAST-ATOM-BOMBARDMENT INTERFACE
    MOSELEY, MA
    DETERDING, LJ
    TOMER, KB
    JORGENSON, JW
    JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01): : 167 - 173
  • [43] Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry
    Zhang, B.
    Liu, H.
    Karger, B.L.
    Foret, F.
    Analytical Chemistry, 71 (15): : 3258 - 3264
  • [44] Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry
    Zhang, B
    Liu, H
    Karger, BL
    Foret, F
    ANALYTICAL CHEMISTRY, 1999, 71 (15) : 3258 - 3264
  • [45] MASS-SPECTROMETRY OF BIOPOLYMERS ISOLATED BY CAPILLARY ELECTROPHORESIS AND CAPILLARY LIQUID-CHROMATOGRAPHY
    MONNIG, CA
    HAGEN, JJ
    CHIU, RW
    CASTORO, JA
    WILKINS, CL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 94 - ANYL
  • [46] Capillary zone electrophoresis electrospray mass spectrometry of priority phenols
    Tsai, CY
    Her, GR
    JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (02) : 315 - 321
  • [47] Advantages of pressurization in capillary electrophoresis/electrospray ionization mass spectrometry
    Hau, J
    Roberts, M
    ANALYTICAL CHEMISTRY, 1999, 71 (18) : 3977 - 3984
  • [48] INDUSTRIAL APPLICATIONS OF CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY
    NIELEN, MWF
    JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) : 269 - 284
  • [49] Sheathless interface to match flow rate of capillary electrophoresis with electrospray mass spectrometry using regular-sized capillary
    Yin, Yue
    Li, Gongyu
    Guan, Yafeng
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 : 68 - 72
  • [50] Recent advances in capillary electrophoresis/electrospray-mass spectrometry
    von Brocke, A
    Nicholson, G
    Bayer, E
    ELECTROPHORESIS, 2001, 22 (07) : 1251 - 1266