INFLUENCE OF CAPILLARY DIMENSIONS ON THE PERFORMANCE OF A COAXIAL CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY INTERFACE

被引:23
|
作者
TETLER, LW [1 ]
COOPER, PA [1 ]
POWELL, B [1 ]
机构
[1] ZENECA SPECIALTIES,MANCHESTER M9 3DA,LANCS,ENGLAND
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/0021-9673(94)01171-A
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The dimensions of the capillaries used to construct a typical coaxial capillary electrophoresis-mass spectrometry (CE-MS) interface, i.e. the inner diameter, the outer diameter and the wall thickness, have been shown to affect the performance of the CE-MS system. The influence of these parameters has been investigated in both MS and MS-MS modes. The initial results indicate that by reducing all the sheath capillaries' dimensions and the CE capillary outer diameter, better operation and increased sensitivity can be achieved. The capillary arrangement which gives optimum sensitivity and stable operation has been suggested.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [21] NEW DEVELOPMENTS IN MICROSCALE SEPARATIONS AND MASS-SPECTROMETRY FOR BIOMONITORING - CAPILLARY ELECTROPHORESIS AND ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    SMITH, RD
    WAHL, JH
    LIGHTWAHL, KJ
    WINGER, BE
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1993, 40 (2-3): : 147 - 158
  • [22] A novel sheathless interface for capillary electrophoresis/electrospray ionization mass spectrometry using an in-capillary electrode
    Cao, P
    Moini, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (05) : 561 - 564
  • [23] INSTRUMENTATION FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    SMITH, RD
    UDSETH, HR
    BARINAGA, CJ
    EDMONDS, CG
    JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2): : 197 - 208
  • [24] OPTIMIZATION OF CAPILLARY ZONE ELECTROPHORESIS ELECTROSPRAY IONIZATION PARAMETERS FOR THE MASS-SPECTROMETRY AND TANDEM MASS-SPECTROMETRY ANALYSIS OF PEPTIDES
    MOSELEY, MA
    JORGENSON, JW
    SHABANOWITZ, J
    HUNT, DF
    TOMER, KB
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) : 289 - 300
  • [25] Analysis of gangliosides by capillary zone electrophoresis and capillary zone electrophoresis electrospray mass spectrometry
    Ju, DD
    Lai, CC
    Her, GR
    JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) : 195 - 203
  • [26] PHYSICOCHEMICAL DATA ON PEPTIDES AND PROTEINS BY CAPILLARY ELECTROPHORESIS AND CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    JORGENSON, JW
    MOSELEY, WA
    MOORE, AW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 55 - ANYL
  • [27] A sheathless nanoflow electrospray interface for on-line capillary electrophoresis mass spectrometry
    Janini, GM
    Conrads, TP
    Wilkens, KL
    Issaq, HJ
    Veenstra, TD
    ANALYTICAL CHEMISTRY, 2003, 75 (07) : 1615 - 1619
  • [28] Evaluation of an electrospray interface for capillary electrophoresis-time-of-flight mass spectrometry
    Lazar, IM
    Lee, ED
    Rockwood, AL
    Lee, ML
    JOURNAL OF CHROMATOGRAPHY A, 1997, 791 (1-2) : 269 - 278
  • [29] Recent advances in capillary electrophoresis/electrospray/mass spectrometry
    Analytica of Branford, Inc., Branford, CT, United States
    不详
    Electrophoresis, 12-13 (2255-2266):
  • [30] MASS-SPECTROMETRY OF PROTEINS ISOLATED BY CAPILLARY ELECTROPHORESIS
    TAKIGIKU, R
    KEOUGH, T
    LACEY, MP
    PURDON, M
    SCHNEIDER, RE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 145 - ANYL