INFLUENCE OF CAPILLARY DIMENSIONS ON THE PERFORMANCE OF A COAXIAL CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY INTERFACE

被引:23
|
作者
TETLER, LW [1 ]
COOPER, PA [1 ]
POWELL, B [1 ]
机构
[1] ZENECA SPECIALTIES,MANCHESTER M9 3DA,LANCS,ENGLAND
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/0021-9673(94)01171-A
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The dimensions of the capillaries used to construct a typical coaxial capillary electrophoresis-mass spectrometry (CE-MS) interface, i.e. the inner diameter, the outer diameter and the wall thickness, have been shown to affect the performance of the CE-MS system. The influence of these parameters has been investigated in both MS and MS-MS modes. The initial results indicate that by reducing all the sheath capillaries' dimensions and the CE capillary outer diameter, better operation and increased sensitivity can be achieved. The capillary arrangement which gives optimum sensitivity and stable operation has been suggested.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [1] IMPROVED ELECTROSPRAY IONIZATION INTERFACE FOR CAPILLARY ZONE ELECTROPHORESIS - MASS-SPECTROMETRY
    SMITH, RD
    BARINAGA, CJ
    UDSETH, HR
    ANALYTICAL CHEMISTRY, 1988, 60 (18) : 1948 - 1952
  • [2] CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY USING AN ELECTROSPRAY IONIZATION INTERFACE
    SMITH, RD
    OLIVARES, JA
    NGUYEN, NT
    UDSETH, HR
    ANALYTICAL CHEMISTRY, 1988, 60 (05) : 436 - 441
  • [3] CAPILLARY ELECTROPHORESIS-ELECTROSPRAY MASS-SPECTROMETRY FOR RECOMBINANT PROTEINS
    TSUJI, K
    BACZYNSKYJ, L
    BRONSON, GE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 8 - ANYL
  • [4] CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    CAI, JY
    HENION, J
    JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) : 667 - 692
  • [5] CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    NIESSEN, WMA
    TJADEN, UR
    VANDERGREEF, J
    JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01): : 3 - 19
  • [6] PEPTIDE AND PROTEIN-ANALYSIS BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY AND CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    LOO, JA
    UDSETH, HR
    SMITH, RD
    ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) : 404 - 412
  • [7] A new high-performance interface for capillary electrophoresis electrospray ionization mass spectrometry
    Severs, JC
    Harms, AC
    Smith, RD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (10) : 1175 - 1178
  • [8] A New High-performance Interface for Capillary Electrophoresis/Electrospray Ionization Mass Spectrometry
    Severs, J. C.
    Harms, A. C.
    Smith, R. D.
    Rapid Communications in Mass Spectrometry, 10 (10):
  • [9] DETERMINATION OF ISOFLAVONES USING CAPILLARY ELECTROPHORESIS IN COMBINATION WITH ELECTROSPRAY MASS-SPECTROMETRY
    ARAMENDIA, MA
    GARCIA, I
    LAFONT, F
    MARINAS, JM
    JOURNAL OF CHROMATOGRAPHY A, 1995, 707 (02) : 327 - 333
  • [10] ONLINE CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF NUCLEOTIDES
    ZHAO, ZX
    WAHL, JH
    UDSETH, HR
    HOFSTADLER, SA
    FUCIARELLI, AF
    SMITH, RD
    ELECTROPHORESIS, 1995, 16 (03) : 389 - 395