ROENTGENOGRAPHIC AND MECHANICAL PERFORMANCE OF CENTRIFUGED CEMENT IN A SIMULATED TOTAL HIP-ARTHROPLASTY MODEL

被引:0
|
作者
CHAO, EYS
CHIN, HC
STAUFFER, RN
机构
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Roentgenographic analysis showed that centrifugation significantly reduced the gross and regional porosity of the cement compared with hand-mixed controls in a simulated total hip arthroplasty model. Static failure test of the prosthetic system demonstrated that the centrifuged cement had significantly greater strength than the hand-mixed cement. Under low-cycle fatigue tests of the same composite models, there was a trend for the centrifuged cement to be stronger than the hand-mixed specimens, although statistically it was not significant. Thus, centrifugation can reduce porosity and significantly improve the static strength of cement in a simulated in vitro total hip replacement model. When cement is used, any possible improvement in the physical properties of bone cement should be considered.
引用
收藏
页码:91 / 101
页数:11
相关论文
共 50 条
  • [31] TREATMENT OF THE SEPTIC HIP WITH TOTAL HIP-ARTHROPLASTY
    BALDERSTON, RA
    HILLER, WDB
    IANNOTTI, JP
    PICKENS, GT
    BOOTH, RE
    GLUCKMAN, SJ
    BUCKLEY, RM
    ROTHMAN, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (221) : 231 - 237
  • [32] ASSESSMENT OF INDICATIONS FOR TOTAL KNEE ARTHROPLASTY AND TOTAL HIP-ARTHROPLASTY
    MANCUSO, CA
    RANAWAT, CS
    FLYNN, WF
    CHARLSON, ME
    ARTHRITIS AND RHEUMATISM, 1992, 35 (09): : S320 - S320
  • [33] REVISION OF INFECTED TOTAL HIP-ARTHROPLASTY
    WEBER, FA
    LAUTENBACH, EEG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (211) : 108 - 115
  • [34] RHABDOMYOLYSIS FOLLOWING TOTAL HIP-ARTHROPLASTY
    LACHIEWICZ, PF
    LATIMER, HA
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04): : 576 - 579
  • [35] TOTAL HIP-ARTHROPLASTY - CLINICAL PERSPECTIVE
    CALLAGHAN, JJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (276) : 33 - 40
  • [36] DISLOCATION FOLLOWING TOTAL HIP-ARTHROPLASTY
    KRISTIANSEN, B
    JORGENSEN, L
    HOLMICH, P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1985, 103 (06) : 375 - 377
  • [37] REVISION OF TOTAL HIP-ARTHROPLASTY IN OCTOGENARIANS
    BALLARD, WT
    CALLAGHAN, JJ
    JOHNSTON, RC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (04): : 585 - 589
  • [38] COMPOSITE TECHNOLOGY FOR TOTAL HIP-ARTHROPLASTY
    SKINNER, HB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (235) : 224 - 236
  • [39] ACETABULAR CEMENT COMPACTOR - AN EXPERIMENTAL-STUDY OF PRESSURIZATION OF CEMENT IN THE ACETABULUM IN TOTAL HIP-ARTHROPLASTY
    OH, I
    MERCKX, DB
    HARRIS, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1983, (177) : 289 - 293
  • [40] OSTEONECROSIS OF THE FEMORAL-HEAD TREATED WITH TOTAL HIP-ARTHROPLASTY WITHOUT CEMENT
    PISTON, RW
    ENGH, CA
    DECARVALHO, PI
    SUTHERS, K
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (02): : 202 - 214