ROENTGENOGRAPHIC AND MECHANICAL PERFORMANCE OF CENTRIFUGED CEMENT IN A SIMULATED TOTAL HIP-ARTHROPLASTY MODEL

被引:0
|
作者
CHAO, EYS
CHIN, HC
STAUFFER, RN
机构
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Roentgenographic analysis showed that centrifugation significantly reduced the gross and regional porosity of the cement compared with hand-mixed controls in a simulated total hip arthroplasty model. Static failure test of the prosthetic system demonstrated that the centrifuged cement had significantly greater strength than the hand-mixed cement. Under low-cycle fatigue tests of the same composite models, there was a trend for the centrifuged cement to be stronger than the hand-mixed specimens, although statistically it was not significant. Thus, centrifugation can reduce porosity and significantly improve the static strength of cement in a simulated in vitro total hip replacement model. When cement is used, any possible improvement in the physical properties of bone cement should be considered.
引用
收藏
页码:91 / 101
页数:11
相关论文
共 50 条
  • [21] CEMENT INTERFACE TEMPERATURE IN HIP-ARTHROPLASTY
    TOKSVIGLARSEN, S
    FRANZEN, H
    RYD, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (02): : 102 - 105
  • [22] CHARNLEY TOTAL HIP-ARTHROPLASTY WITH CEMENT - 15-YEAR RESULTS
    KAVANAGH, BF
    DEWITZ, MA
    ILSTRUP, DM
    STAUFFER, RN
    COVENTRY, MB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (10): : 1496 - 1503
  • [23] FEMORAL CEMENT REMOVAL IN REVISION TOTAL HIP-ARTHROPLASTY - A BIOMECHANICAL ANALYSIS
    DENNIS, DA
    DINGMAN, CA
    MEGLAN, DA
    OLEARY, JFM
    MALLORY, TH
    BERME, N
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (220) : 142 - 147
  • [24] EFFECT OF STEM MODULUS IN A TOTAL HIP-ARTHROPLASTY MODEL
    MAISTRELLI, GL
    FORNASIER, V
    BINNINGTON, A
    MCKENZIE, K
    SESSA, V
    HARRINGTON, I
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01): : 43 - 46
  • [25] SUCCESSIVE DISLOCATIONS OF A TOTAL HIP-ARTHROPLASTY COMPLICATED BY ACRYLIC CEMENT INTERPOSITION
    THEIS, JC
    DUNBAR, JD
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1990, 60 (11): : 922 - 923
  • [26] AN AXISYMMETRIC MODEL OF ACETABULAR COMPONENTS IN TOTAL HIP-ARTHROPLASTY
    PEDERSEN, DR
    CROWNINSHIELD, RD
    BRAND, RA
    JOHNSTON, RC
    JOURNAL OF BIOMECHANICS, 1982, 15 (04) : 305 - +
  • [27] GIRDLESTONE ARTHROPLASTY FOR INFECTED TOTAL HIP-ARTHROPLASTY
    BITTAR, ES
    PETTY, W
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1982, (170) : 83 - 87
  • [28] THE INFECTED HIP AFTER TOTAL HIP-ARTHROPLASTY
    CANNER, GC
    STEINBERG, ME
    HEPPENSTALL, RB
    BALDERSTON, R
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (09): : 1393 - 1399
  • [29] CEMENT-WITHIN-CEMENT REVISION HIP-ARTHROPLASTY
    LIEBERMAN, JR
    MOECKEL, BH
    EVANS, BG
    SALVATI, EA
    RANAWAT, CS
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (06): : 869 - 871
  • [30] TOTAL HIP-ARTHROPLASTY IN THE HIGH DISLOCATED HIP
    MENDES, DG
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1981, 17 (01): : 57 - 57